1. Introduction
The TOOLTOP ET928 is a versatile 3-in-1 device combining the functionalities of an oscilloscope, a digital multimeter, and a signal generator. Designed for portability and ease of use, it features a 2.4-inch color screen, a 12MHz bandwidth oscilloscope with a 50Msps sampling rate, and a comprehensive multimeter with 6000 counts. This manual provides essential information for the safe and effective operation and maintenance of your ET928 device.

2. Setup
2.1 Package Contents
Before using your ET928, please verify that all items are present in the package:
- 1 x TOOLTOP ET928 3-in-1 Oscilloscope + Multimeter + Signal Generator
- 1 x Test Probe (Red and Black leads)
- 1 x USB Cable (Type-C)
- 1 x User Manual
- 1 x Storage Box

2.2 Battery and Charging
The ET928 is powered by a built-in lithium battery. It is recommended to fully charge the device before first use. The charging interface is a Type-C port.
- Charging: Connect the provided USB Type-C cable to the charging interface on the device and a suitable USB power adapter (5V/1A recommended). The charging indicator light will illuminate.
- Battery Life: A full charge provides approximately 6 hours of continuous usage.
- Low Battery Reminder: The device features a low battery reminder to alert you when charging is needed.
- Automatic Shutdown: To conserve battery life, the device will automatically shut down after 15 minutes of inactivity (this feature can be disabled).
2.3 Port Description and Controls
Familiarize yourself with the device's ports and buttons:

- Charging Indicator Light: Indicates charging status.
- Charging Interface: USB Type-C port for charging.
- Multi-Function Buttons (F1, F2, F3, F4): Context-sensitive buttons for menu navigation and function selection.
- AUTO Button: For automatic settings in oscilloscope mode or auto-ranging in multimeter mode.
- Cx/Hz% Button: For capacitance and frequency/duty cycle measurements.
- SAVE Button: To save current DMM data or oscilloscope waveforms.
- Backlight/Signal Output Button: Controls backlight or activates signal output.
- Data Retention/Storage Button: For holding data or accessing stored records.
- Functional Range Knob: Rotary switch to select different measurement modes (Oscilloscope, Multimeter functions like V, mV, A, mA, Ω, Diode, On-off test, Signal Generator).
- 10A Current Input Terminal: For high current measurements (up to 10A).
- Signal Output/Current Input Terminal (Out mA): For signal generation output or low current measurements (mA/µA).
- COM Input: Common ground terminal for all measurements.
- Oscillographic/Voltage/Resistance/Current Input Port (VΩCx): Main input for voltage, resistance, capacitance, and oscilloscope measurements.
3. Operating Instructions
3.1 General Operation
Turn the functional range knob to the desired mode. The 2.4-inch color screen will display the relevant interface and readings.

3.2 Multimeter Function
The multimeter function allows for precise measurements of various electrical parameters with a 6000-count display. Rotate the functional range knob to the desired measurement type (V, A, Ω, Cx, Diode, On-off test).
- Voltage (AC/DC): Connect test probes to the VΩCx and COM ports. Select ACV or DCV using the knob.
- Current (AC/DC): For low currents (mA/µA), connect probes to Out mA and COM. For high currents (up to 10A), connect to 10A and COM. Select ACA or DCA.
- Resistance: Connect probes to VΩCx and COM. Select Ω.
- Capacitance: Connect probes to VΩCx and COM. Select Cx.
- Frequency/Duty Cycle: Connect probes to VΩCx and COM. Select Hz%.
- Diode Test: Connect probes to VΩCx and COM. Select Diode.
- On-off Test (Continuity): Connect probes to VΩCx and COM. Select On-off test.

3.3 Oscilloscope Function
The ET928 features a one-click oscilloscope function to automatically display waveforms. Rotate the functional range knob to the oscilloscope mode.
- AUTO Mode: Waveforms can be collected without specific triggering conditions.
- NORMAL Mode: Waveforms can be collected without specific triggering conditions.
- SINGLE Mode: Waveforms can be collected without specific triggering conditions.
- Use the F1-F4 buttons to adjust settings like time base, vertical sensitivity, and trigger.

3.4 Signal Generator Function
The built-in signal generator can output sine, square, and triangular waves with adjustable frequency, amplitude, and duty cycle. Rotate the functional range knob to the signal generator mode.
- Waveform Selection: Use the F1-F4 buttons to select Sine, Square, or Triangular wave.
- Frequency Adjustment: Adjust the output frequency (Sine: 100Hz-100kHz, Square: 100Hz-20kHz, Triangular: 100Hz-50kHz).
- Amplitude Adjustment: Adjust the output amplitude (5Vpp, 2.5Vpp, 1Vpp, 0.5Vpp, 0.2Vpp, 0.1Vpp, 0Vpp).
- Duty Cycle Adjustment: Adjust the duty cycle for square waves.
- Connect the output to the Out mA terminal.

3.5 Data Storage
The ET928 has a high storage capacity, allowing you to save important measurement data and waveforms.
- DMM Data: Can store up to 100 sets of multimeter data.
- Waveforms: Can store up to 10 oscilloscope waveforms.
- Saving: Press the "SAVE" key to store the current measurement or waveform.

4. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will be stored for an extended period.
- Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage conditions are -10°C to +60°C with less than 90% RH.
- Fuse Replacement: The device uses 500mA/250V and 10A/250V fuses. If a fuse blows, replace it with one of the same type and rating. Refer to the specifications for exact fuse details.
5. Troubleshooting
If you encounter issues with your TOOLTOP ET928, please refer to the following common troubleshooting steps:
- Device not turning on: Ensure the battery is charged. Connect the device to a power source using the USB cable and try again.
- Incorrect readings: Check that the test probes are correctly connected to the appropriate input terminals for the selected measurement function. Verify that the functional range knob is set to the correct mode. Ensure the probes are making good contact with the circuit.
- No waveform displayed in oscilloscope mode: Check probe connections. Ensure the signal source is active. Try adjusting the time base and vertical sensitivity settings, or use the AUTO function.
- Signal generator not outputting: Verify the output terminal connection (Out mA). Ensure the signal generator mode is selected and parameters (frequency, amplitude) are set correctly.
- Screen issues (no display, flickering): Try restarting the device. If the problem persists, contact customer support.
For more complex issues, please consult the full user manual (if available) or contact customer support.
6. Specifications
6.1 General Features
| Feature | Description |
|---|---|
| Display | 240 x 320 Color Screen (LCM) |
| Backlight | Ever Bright / White |
| Battery | One 18650 Lithium battery (1500mAH) |
| Automatic Sleep | 15 minutes or disabled |
| Static Operating Current (Multimeter) | About 80mA |
| Static Operating Current (Oscilloscope) | About 300mA |
| Shutdown Current | Less than 10µA |
| Duration of Continuous Use | More than 8 hours (approx. 6 hours) |
| Save Capability | 100 records of DMM data, 10 records of OSC waveforms |
| Usage Environment | 0℃~+40℃, <75%RH |
| Outline Dimensions | 83 mm x 160 mm x 32mm (153mm x 75mm x 30mm) |
| Charging Standard | 5V/1A |
| Charging Port | Type-C |
| Observation Area | 49.0mm x 36.7mm (2.4 inches) |
| Input Resistance | About 5MΩ (Oscilloscope), 10MΩ (General) |


6.2 Multimeter Function Parameters
| Category | Range | Uncertainty |
|---|---|---|
| DC Voltage | 60mV/600mV, 6V/60V/600V/1000V | (0.75%rdg + 10dgt) |
| AC Voltage | 60mV/600mV, 6V/60V/600V/750V | (1.0%rdg + 10dgt) |
| DC Current | 600uA/6000uA, 60mA/500mA, 6A/10A | (1.2%rdg + 10dgt) |
| AC Current | 600uA/6000uA, 60mA/500mA, 6A/10A | (1.5%rdg + 10dgt) |
| Resistance | 600.0Ω ~ 60.00MΩ | (1.0%rdg + 5dgt) |
| Capacitors | 10nF ~ 100mF | (2%rdg + 10dgt) |
| Frequency | 5Hz ~ 100kHz (Merge voltage shift) 5Hz ~ 10MHz | (1.0%rdg + 5dgt) |
| Duty Cycle | 0.1% ~ 99.9% (Merge voltage shift) | (1.0%rdg + 5dgt) |
| Diode Test | Open circuit voltage is about 3V, max test current about 2mA | |
| On-off Test | Judging resistance: approximately <50 Ω | |
| Fuse | 500mA/250V, 10A/250V |

6.3 Oscilloscope Features
| Feature | Description |
|---|---|
| Simulation Bandwidth | DC ~ 8MHz (50mV/div ~ 200V/div) |
| Bandwidth | DC ~ 12MHz (20V/div ~ 20V/div) |
| Maximum Equivalent Sampling Rate | 50Msps |
| Number of Channels | 1 |
| Vertical Sensitivity Range | 500mV ~ 200V/div |
| Vertical Range Accuracy | ±(3% + 0.2/div) |
| Time Base Range | 200ns ~ 10s/div |
| Time Base Accuracy | ±(0.01% + 0.1/div) |
| Scan Mode | Auto/Normal/Single |
| Trigger Edge Selection | Rising/Falling edge |
| Automatic Settings | Automatic setting of time base and vertical range |
| Automatic Measurement Function | Vp-p, Vavg, Vrms, Hz |
6.4 Signal Source Features
| Feature | Description |
|---|---|
| Output Frequency | Sine wave: 100Hz~100kHz (fixed-point output in 1-2-5 steps) Square wave: 100Hz~20kHz (fixed-point output in 1-2-5 steps) Triangular wave: 100 Hz ~ 50kHz (fixed-point output in 1-2-5 step mode) |
| Output Amplitude | 5Vpp, 2.5Vpp, 2Vpp, 1.5Vpp, 1Vpp, 0.5Vpp, 0.4Vpp, 0.3Vpp, 0.2Vpp, 0.1Vpp, 0Vpp |
7. User Tips
- Probe Connection: Always ensure test probes are securely connected to the correct input terminals before taking any measurements to prevent damage to the device or inaccurate readings.
- Mode Selection: Double-check the functional range knob is set to the appropriate measurement mode for your task. Using the wrong mode can lead to incorrect results or potential hazards.
- Battery Management: For optimal performance and longevity, avoid completely draining the battery. Charge the device when the low battery reminder appears.
- Data Review: Utilize the data storage feature to record and review measurements, especially for intermittent signals or long-term monitoring.
- Environmental Conditions: Operate the device within the specified usage environment (0℃~+40℃, <75%RH) to ensure accuracy and prevent damage.
8. Warranty and Support
The TOOLTOP ET928 is designed for reliability and performance. For any technical assistance, warranty claims, or support inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase for warranty purposes.