1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the CERTEON OF05ZAT Plastic Gear Flow Sensor. This miniature flow rate sensor is designed for precise liquid flow measurement and is widely used in various industrial and commercial applications. It is a durable and high-precision instrument suitable for measuring non-corrosive, low-viscosity liquids.

2. Specifications
The OF05ZAT Gear Flow Sensor comes in various connection types, each with specific flow ranges and dimensions. Below are the general and specific parameters:
| Parameter | Specification | Parameter | Specification |
|---|---|---|---|
| Interface Size | G1/4 / G3/8 / G1/2 / G3/4 | Material | PPS |
| Inner/Outer Diameter | 8mm/12.5mm (G3/8), 10mm/20.5mm (G1/2), 16mm/26mm (G3/4) | Voltage Range | DC3.5-24V |
| Thread Length | 10mm (G1/4), 29mm (G3/8, G1/2), 18.7mm (G3/4) | Current | ≤10mA (DC5V) |
| Flow Range | 18-300L/H (G1/4), 30-1200L/H (G3/8, G1/2), 30-3000L/H (G3/4) | Accuracy | ±1% (varies by model) |
| Frequency Formula | F=(8.5 × Q) ±2% (G1/4), F=2.5 × Q (G3/8, G1/2), F=1.2 × Q (G3/4) | Pulse Unit | 0.54ML/P (G1/4) |
| Operating Temp | -10°C to 70°C (G1/4), ≤80°C (others) | Operating Humidity | 35%-90%RH (no condensation) |
| Max Pressure | ≤1.0MPa (G1/4), ≤1.2MPa (others) | Storage Temp | -25°C to +80°C |
| Storage Humidity | 25%-95%RH | Applicable Medium | Non-corrosive, low-viscosity liquids |



3. Product Overview
The CERTEON Gear Flow Sensor is constructed from high-quality PPS material, ensuring durability and resistance to various liquids. It incorporates a Hall sensor, imported from the USA, and features Japanese O-ring waterproof sealing with enhanced silicone protection at the cable outlet for reliable performance. The sensor is designed for high precision and sensitivity.


4. Setup and Installation
Before installation, ensure the chosen sensor model (G1/4, G1/2, G3/4, G3/8) matches your application's pipe size and flow requirements. The sensor should be installed in a section of the pipeline where the liquid flow is stable and free from turbulence. Observe the arrow on the sensor body, which indicates the correct direction of liquid flow. Install the sensor in alignment with this arrow to ensure accurate readings.

5. Wiring Instructions
The flow sensor uses a 3-wire connection for power and signal output. Follow the wiring diagram below for proper connection:
- Red (IN): Connect to the positive (+) terminal of your DC power supply (DC3.5-24V).
- Yellow (OUT): This is the signal output wire, providing an NPN pulse signal. Connect it to your measurement or control device.
- Black (GND): Connect to the negative (-) terminal of your DC power supply.

6. Operation
Once installed and wired correctly, the sensor will output a pulse signal proportional to the liquid flow rate. The frequency of this pulse (F) can be used to calculate the flow rate (Q) in L/min using the specific frequency formulas provided in the specifications section for your model. For example, for G1/2 and G3/8 models, F = 2.5 × Q (L/min).

7. Maintenance
To ensure the longevity and accuracy of your flow sensor, follow these maintenance guidelines:
- Liquid Purity: This sensor is designed for clean, non-corrosive, low-viscosity liquids. Avoid using it with liquids containing impurities, as this can affect performance and cause damage.
- Prevent Solidification: Ensure that the liquid being measured does not solidify within the sensor, especially in low-temperature environments. Liquid solidification can cause the internal rotor to stop, leading to inaccurate readings or damage, and is not covered under warranty.
- Regular Inspection: Periodically inspect the sensor for any signs of wear, leaks, or damage to the connections and housing.
- Cleaning: If necessary, clean the exterior of the sensor with a soft, damp cloth. Do not use harsh chemicals or abrasive materials.
8. Troubleshooting (FAQ)
- Q: What is the correct wiring method?
- A: Connect the red wire to positive (+), the black wire to negative (-), and the yellow wire is for the NPN pulse signal output.
- Q: Can this sensor measure liquids with impurities?
- A: No, it is not designed for liquids with impurities. Using it with such liquids may lead to inaccurate readings or damage.
- Q: What if the rotor stops due to liquid solidification?
- A: If the liquid solidifies and causes the internal rotor to stop turning, this is not considered a quality issue and will not be covered under after-sales service.
- Q: What types of liquids can it measure?
- A: It is mainly used for non-corrosive, low-viscosity liquids such as milk, chemicals, paints, and detergents. It is also suitable for water and various oils.
9. User Tips
- Select Correct Size: Always choose the appropriate connection type (G1/4, G1/2, G3/4, G3/8) based on your piping system and desired flow range for optimal accuracy.
- Power Supply: Utilize a stable DC3.5-24V power supply to ensure consistent performance.
- Liquid Compatibility: For best results and to prevent damage, only use the sensor with clean, non-corrosive, low-viscosity liquids.
- Flow Direction: Pay close attention to the flow direction arrow on the sensor during installation to ensure correct measurement.
10. Warranty and Support
For technical assistance, product support, or inquiries regarding specific warranty terms, please contact the manufacturer or your point of purchase. Ensure you have your product model number (OF05ZAT) and any relevant purchase information available when seeking support.