1. Introduction
Thank you for choosing the VEVOR Portable Diesel Air Heater. This manual provides essential information for the safe and efficient operation, setup, and maintenance of your heater. Designed for versatility, this 12V/24V heater offers fast heating, low fuel consumption, and multiple control options, making it ideal for outdoor camping, RVs, garages, and other spaces requiring portable warmth.
This heater features an innovative CO alarm system and is compatible with various power sources, ensuring comfort and safety in diverse environments.

2. Important Safety Information
Please read and understand all safety warnings and instructions before using this product. Failure to follow these instructions may result in fire, explosion, electric shock, or other hazards.
2.1 Carbon Monoxide (CO) Alarm System
- The heater is equipped with an innovative CO alarm system for continuous monitoring of carbon monoxide levels.
- An alert will be triggered at 300 ppm.
- The unit will automatically shut down if CO levels reach 500 ppm to prevent CO poisoning from incomplete combustion.
- Always ensure proper ventilation when operating the heater.

2.2 General Safety Features
- Overheat Protection: The heater includes overheat protection, activating at temperatures ≥ 464°F (240°C).
- Fuel Tank Gauge: A visible fuel tank gauge helps monitor fuel levels to prevent running dry.
- Leak-Proof Fuel Cap: Designed to prevent fuel leakage.
- Exhaust Pipe Protection: The exhaust pipe is designed with protection to minimize vulnerability.

2.3 Operation Warnings
- Always ensure the exhaust is vented outside to prevent carbon monoxide buildup.
- Do not block the air intake or outlet.
- Use only recommended diesel fuel.
- Keep flammable materials away from the heater.
- Do not operate the heater in enclosed, unventilated spaces.
3. Package Contents
Please check the package to ensure all items are present and undamaged. If any parts are missing or damaged, contact customer support.

For Model ZM2003 (2KW), the package typically includes:
- 1 x Diesel Air Heater Unit
- 1 x Exhaust Pipe
- 1 x Air Outlet Pipe
- 1 x Remote Control
- 1 x Muffler
- 4 x Exhaust Pipe Clamps
- 6 x Exhaust Pipe Hanger Screws
- 2 x Exhaust Pipe Hangers
- 1 x Air Purifier
- 10 x Base Fixing Screws
- 1 x Air Direction Rotating Joint
- 1 x Adapter
- 1 x DC12V Two-Pin Power Cable
- 1 x User Manual
- 1 x Quick Connector
- 1 x Exhaust Pipe Heat Insulation Sleeve
- 4 x Feet
- 1 x CO Module, Extension Cable
Note: Contents may vary slightly between models (e.g., ZM2003 2KW vs. CY5002 8KW). Refer to your specific model's packaging for exact details.
4. Specifications
| Feature | ZM2003 (2KW) | CY5002 (8KW) |
|---|---|---|
| Operating Voltage | DC12V-24V | DC12V-24V |
| Maximum Combustion Power | 2 kW | 8 kW |
| Net Weight | 15.7 lbs / 7.1 kg | 18.7 lbs / 8.50 kg |
| Applicable Altitude | Up to 9842.5 ft / 3000 m | Up to 9842.5 ft / 3000 m |
| Product Dimensions (L×W×H) | 13×5.5×12.6 in / 330×140×321 mm | 16.9×8.1×14 in / 430×205×355 mm |
| Combustion Efficiency | ≥90% | ≥90% |
| Fuel Consumption | 0.07-0.17 L/h | 0.18-0.35 L/h |
| Noise Level | ≤75 dB | ≤75 dB |
| Overheat Protection | ≥ 464°F / 240°C | ≥ 464°F / 240°C |
5. Setup and Installation
5.1 Placement
- Place the heater on a stable, level surface.
- Ensure adequate clearance around the heater for proper airflow and to prevent fire hazards.
- Always ensure the exhaust pipe is routed outside and away from any flammable materials or living spaces.
5.2 Power Connection
The VEVOR Diesel Air Heater offers versatile power options:
- DC 12V-24V Vehicle Power Supply: Connect directly to your vehicle's battery using the provided DC12V Two-Pin Power Cable.
- Mains Power (Garage Outlet): Use the included adapter and power cable to connect to a standard wall outlet.
- Portable Power Station: Connect to a compatible outdoor power station for mobile use.
The plug-and-play design simplifies connection, requiring no complex assembly.

5.3 Fuel Filling
- Ensure the heater is turned off and cooled down before refilling fuel.
- Use only clean diesel fuel.
- Monitor the fuel tank gauge to avoid overfilling.
- Securely close the leak-proof fuel cap after refilling.
5.4 Exhaust System Installation
- Connect the exhaust pipe and muffler as shown in the package contents diagram.
- Use the provided clamps and hanger screws to secure the exhaust system.
- Crucially, ensure the exhaust is vented completely outside the heated area to prevent carbon monoxide accumulation.
6. Operating Instructions
Your VEVOR Diesel Air Heater can be controlled via three intelligent methods:
6.1 Display Panel Control
- The integrated HD display panel allows for direct operation and real-time status updates.
- Use the buttons on the panel to power on/off, adjust temperature, and access settings.
6.2 Remote Control
- The included remote control allows you to operate the heater from a distance of up to 98 ft (30 m).
- Point the remote towards the heater's receiver and use the ON/OFF buttons to control the unit.
6.3 Bluetooth APP Control
- Download the dedicated VEVOR app on your smartphone.
- Pair your smartphone with the heater via Bluetooth (range up to 98 ft / 30 m).
- The app provides comprehensive control, including:
- Power On/Off
- Temperature Adjustment (6-level adjustable, 32°F~104°F / 0°C~40°C)
- Timer Function
- Preheating Function
- Overheat Protection monitoring
- Voice Broadcast


6.4 Quiet Operation
The heater is designed with a premium muffler and fuel pump to minimize noise, operating at ≤75dB, ensuring a warm and undisturbed environment.
7. Maintenance
Regular maintenance ensures the longevity and efficient operation of your diesel air heater.
- Cleaning: Periodically clean the exterior of the heater with a soft, damp cloth. Ensure the air intake and outlet are free from dust and debris.
- Fuel Filter: Check and clean or replace the fuel filter as needed to ensure clean fuel supply.
- Exhaust System: Inspect the exhaust pipe and muffler for any blockages or damage. Ensure all connections are secure.
- Storage: When not in use for extended periods, drain any remaining fuel, clean the unit, and store it in a dry, safe place.
8. Troubleshooting
If you encounter issues with your heater, refer to the following common problems and solutions:
- Heater not starting: Check power connections, ensure sufficient fuel, and verify that the CO alarm is not triggered.
- Low heat output: Ensure air intake/outlet are not blocked. Check fuel quality and filter.
- Unusual noise: Inspect the exhaust system for loose connections or obstructions.
- CO alarm triggered: Immediately ensure proper ventilation. Check for exhaust blockages or leaks. If the alarm persists, cease operation and seek professional assistance.
For persistent issues, please contact VEVOR customer support.
9. User Tips
- Always prioritize proper ventilation, especially when using the heater in enclosed spaces like RVs or tents, to prevent carbon monoxide buildup.
- Keep the fuel tank adequately filled to avoid interruptions during operation.
- Familiarize yourself with all three control methods (display panel, remote, app) for maximum convenience in different situations.
10. Warranty and Support
VEVOR provides a one-year warranty for this product, covering manufacturing defects and ensuring resolution for after-sales problems. For warranty claims, technical support, or any inquiries, please contact VEVOR customer service through their official channels.