PowMr Hybrid Solar Inverter Charger User Manual

Models: POW-HVM2H-12V-N, POW-HVM3.2H-24V-N

1. Introduction

This PowMr Hybrid Solar Inverter Charger is a multi-function device that combines the capabilities of an inverter, solar charger, and battery charger. It is designed to provide uninterruptible power support in a compact size. The unit features a comprehensive LCD display and user-configurable button operations for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage, making it adaptable to various applications.

1.1 Key Features

  • Pure sine wave inverter output.
  • Configurable input voltage range for home appliances and personal computers via LCD settings.
  • Configurable battery charging current based on applications via LCD settings.
  • Configurable AC/Solar Charger priority via LCD settings.
  • Compatible with mains voltage or generator power.
  • Automatic restart when AC power is restored.
  • Built-in protection against overload, over temperature, and short circuit.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Optional WIFI/GPRS module for remote monitoring.
  • Compatibility with various battery types, including lithium-ion and lead-acid batteries.

1.2 Basic System Architecture

The inverter/charger forms the core of a complete power system. It typically integrates with PV modules (solar panels) and can connect to a generator or utility grid. This setup allows the inverter to power various home or office appliances, including motor-type loads like refrigerators and air conditioners.

Hybrid Power System Diagram for 2KVA 12V Inverter
Figure 1: Hybrid Power System Diagram (2KVA 12V model example)
Hybrid Power System Diagram for 3.2KVA 24V Inverter
Figure 2: Hybrid Power System Diagram (3.2KVA 24V model example)

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION – To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION – Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable sizes. It is very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Product Overview

The front panel of the inverter features an LCD display, indicators, and function buttons for monitoring and control. The rear and side panels provide connection ports for AC input/output, PV input, and battery input, along with a power on/off switch.

Product Overview Diagram with Labeled Components
Figure 3: Product Overview with Labeled Components

3.1 Component Identification

  1. LCD Display
  2. Status Indicator
  3. Charging Indicator
  4. Fault Indicator
  5. Function Buttons
  6. Power On/Off Switch
  7. AC Input
  8. AC Output
  9. PV Input
  10. Battery Input
  11. Communication Port (RS-232)
Various views of the PowMr Solar Inverter Charger
Figure 4: Product Views (Front, Side, Rear)

4. Installation

4.1 Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that no damage occurred during transit. The package should contain the inverter unit and a user manual.

4.2 Preparation

Before connecting any wiring, remove the bottom cover of the unit by unscrewing two screws.

4.3 Mounting the Unit

When selecting a mounting location, consider the following:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install the inverter at eye level for easy readability of the LCD display.
  • Ensure proper air circulation for heat dissipation. Allow approximately 20 cm clearance to the sides and 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • The recommended installation position is vertically on a wall.
  • Keep other objects and surfaces clear as shown in the diagram to guarantee sufficient heat dissipation and space for wiring.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two screws. M4 or M5 screws are recommended.

4.4 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for typical amperage and required fuse/breaker size.

WARNING! All wiring must be performed by qualified personnel.

WARNING! Use appropriate cables for battery connection to ensure system safety and efficient operation.

ModelWire SizeCable (mm²)Torque Value (max)
2.0KVA 12V1 x 4AWG222 Nm
3.2KVA 24V1 x 6AWG142 Nm

Battery Connection Steps:

  1. Remove 18 mm of insulation sleeve for positive and negative conductors.
  2. Suggest using bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into the battery connectors of the inverter and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure correct polarity at both the battery and the inverter/charger, and that conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
Battery Connection Diagram for 2KVA 12V and 3.2KVA 24V Inverters
Figure 5: Battery Connection Diagram

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).

4.5 AC Input/Output Connection

CAUTION!! Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. Recommended AC breaker specs: 10A for 2.0KVA and 32A for 3.2KVA.

CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel.

WARNING! Use appropriate cables for AC input connection to ensure system safety and efficient operation.

Suggested Cable Requirement for AC Wires:

ModelGaugeTorque Value
2.0KVA 12V14 AWG0.5~0.6 Nm
3.2KVA 24V12 AWG1.2 Nm

AC Input/Output Connection Steps:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Ensure the PE protective conductor (Ground, yellow-green) is connected first.
  4. Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws.

WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.

4.6 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING! Use appropriate cables for PV module connection to ensure system safety and efficient operation.

PV Module Selection Parameters:

  • Open Circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
  • Open Circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.

Inverter Model PV Array Specifications:

INVERTER MODEL2.0KVA/3.2KVA
Max. PV Array Open Circuit Voltage400Vdc
PV Array MPPT Voltage Range30Vdc~400Vdc
SOLAR INPUT (Min in serial: 4 pcs, max. in serial: 12 pcs)Q'ty of PanelsTotal Input Power
4 pcs in serial4 pcs1000W
6 pcs in serial6 pcs1500W
8 pcs in serial8 pcs2000W
10 pcs in serial10 pcs2500W

PV Module Wire Connection Steps:

  1. Remove 10 mm of insulation sleeve for positive and negative conductors.
  2. Suggest using bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive (+) of the connection wire to positive (+) of the PV input connector. Connect negative (-) of the connection wire to negative (-) of the PV input connector. Recommended tool: 4mm blade screwdriver.

4.7 Final Assembly

After connecting all wirings securely, replace the bottom cover by screwing in the four screws.

5. Operation

5.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the case) to turn on the unit.

5.2 Operation and Display Panel

The front panel features an LCD display, three indicators (Status, Charging, Fault), and four function keys (ESC, UP, DOWN, ENTER) to show operating status and input/output power information.

Inverter Front Panel with LCD and Buttons
Figure 6: Inverter Front Panel

LED Indicator Messages:

LED IndicatorColorMessages
AC / INVGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.

Function Keys:

Function KeyDescription
ESCTo exit setting mode.
UPTo go to previous selection.
DOWNTo go to next selection.
ENTERTo confirm the selection in setting mode or enter setting mode.

5.3 LCD Display Icons

The LCD display provides detailed information about the inverter's status. Icons indicate input source, configuration programs, fault information, output information, and battery status.

Input Source Information:

  • AC Icon: Indicates the AC input.
  • PV Icon: Indicates the PV input.
  • INPUTBATT Display: Shows input voltage, input frequency, PV voltage, charger current (for 2.0KVA models), charger power, and battery voltage.

Configuration Program and Fault Information:

  • Setting Programs Icon: Indicates the setting programs.
  • Warning/Fault Codes Icon: Indicates warning and fault codes. Flashing for warnings, solid for faults.

Output Information:

  • OUTPUTBATTLOAD Display: Shows output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.

Battery Information:

  • CHARGING Icon: Indicates battery level (0-24%, 25-49%, 50-74%, 75-100%) in battery mode and charging status in line mode.
  • In AC mode, it will present battery charging status.

Mode Operation Information:

  • Mains Icon: Indicates unit connects to the mains.
  • PV Panel Icon: Indicates unit connects to the PV panel.
  • BYPASS Icon: Indicates load is supplied by utility power.
  • Utility Charger Icon: Indicates the utility charger circuit is working.
  • DC/AC Inverter Icon: Indicates the DC/AC inverter circuit is working.

Mute Operation:

  • Mute Icon: Indicates unit alarm is disabled.

5.4 LCD Setting

To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to select setting programs, and "ENTER" to confirm or "ESC" to exit.

Key Settings:

  • Program 00: Exit Setting Mode
  • Program 01: Output Source Priority (Utility first, Solar first, SBU priority)
  • Program 02: Maximum Charging Current (10A, 20A, 30A, 40A, 50A, 60A, 70A, 80A)
  • Program 03: AC Input Voltage Range (Appliances, UPS)
  • Program 05: Battery Type (AGM, Flooded, User-Defined)
  • Program 06: Auto Restart when Overload Occurs (Enable/Disable)
  • Program 07: Auto Restart when Over Temperature Occurs (Enable/Disable)
  • Program 09: Output Frequency (50Hz, 60Hz)
  • Program 10: Output Voltage (220V, 230V, 240V)
  • Program 12: Setting Voltage Point Back to Utility Source (Various voltage options for 2.0KVA 12V and 3.2KVA 24V models)
  • Program 13: Setting Voltage Point Back to Battery Mode (Various voltage options for 2.0KVA 12V and 3.2KVA 24V models)
  • Program 16: Charger Source Priority (Solar first, Solar and Utility, Only Solar)
  • Program 18: Alarm Control (Alarm on/off)
  • Program 19: Auto Return to Default Display Screen (Enable/Disable)
  • Program 20: Backlight Control (Backlight on/off)
  • Program 22: Beeps while Primary Source is Interrupted (Alarm on/off)
  • Program 23: Overload Bypass (Enable/Disable)
  • Program 25: Record Fault Code (Enable/Disable)
  • Program 26: Bulk Charging Voltage (C.V voltage) (Various voltage options for 2.0KVA 12V and 3.2KVA 24V models)
  • Program 27: Floating Charging Voltage (Various voltage options for 2.0KVA 12V and 3.2KVA 24V models)
  • Program 29: Low DC Cut-off Voltage (Various voltage options for 2.0KVA 12V and 3.2KVA 24V models)
  • Program 30: Battery Equalization (Enable/Disable)
  • Program 31: Battery Equalization Voltage (Various voltage options for 2.0KVA 12V and 3.2KVA 24V models)
  • Program 33: Battery Equalized Time (5min to 900min)
  • Program 34: Battery Equalized Timeout (5min to 900min)
  • Program 35: Equalization Interval (0 to 90 days)
  • Program 36: Equalization Activated Immediately (Enable/Disable)

5.5 Operating Mode Description

The inverter operates in several modes, each with specific characteristics:

  • Standby Mode / Power Saving Mode: The inverter is not actively providing output but can charge batteries. In power saving mode, the inverter output will turn off if the connected load is very low or not detected.
  • Line Mode: The unit provides output power from the mains and charges the battery. If "solar first" is selected and solar energy is insufficient, solar and utility power will combine to provide load and charge the battery.
  • Battery Mode: The unit provides output power from the battery and PV power. PV energy can supply power to loads and charge the battery simultaneously.
  • Fault Mode: Errors caused by internal circuit issues or external factors like over temperature or short circuits. PV energy and utility can still charge batteries in this mode.

5.6 Battery Equalization Description

The equalization function helps reverse negative chemical effects in batteries, such as stratification and sulfation, which can reduce battery capacity. It is recommended to equalize batteries periodically.

How to Apply Equalization Function:

First, enable the battery equalization function in monitoring LCD setting program 30. Then, you can apply this function by either:

  1. Setting the equalization interval in program 35.
  2. Activating equalization immediately in program 36.

When to Equalize:

In float stage, when the set equalization interval is reached or equalization is activated immediately, the controller will enter the Equalize stage.

Equalize Charging Time and Timeout:

During the Equalize stage, the controller charges the battery until it reaches the equalization voltage. Constant-voltage regulation then maintains this voltage. The battery remains in this stage until the set equalized time is reached. If the battery voltage does not reach the equalization voltage within the timeout period, the charge controller will extend the time until it does. If the voltage is still low after the timeout, equalization will stop, and the unit will return to the float stage.

6. Maintenance

6.1 Anti-Dust Kit (Optional)

The inverter comes with a pre-installed anti-dust kit from the factory. This kit helps keep dust out of the inverter and enhances product reliability in harsh environments. The inverter automatically detects this kit and adjusts its internal thermal sensor to regulate internal temperature.

Clearance and Maintenance Steps:

  1. Remove the screws securing the dustproof case.
  2. Carefully remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. After cleaning, re-assemble the dust-kit back into the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

Intelligent Cooling Fan Diagram
Figure 7: Intelligent Cooling Fan (ensures efficient energy conversion)

7. Troubleshooting

This section provides guidance for common issues. If problems persist, contact customer support.

7.1 Fault Reference Code

Fault CodeFault EventWhat to Do
01Fan is locked when inverter is off.Return to repair center.
02Over temperature.Check air flow, ambient temperature.
03Battery voltage is too high.Check battery connections and settings.
04Battery voltage is too low.Re-charge or replace battery.
05Output short-circuited or over temperature detected by internal converter components.Check wiring, remove abnormal load.
06Output voltage is too high.Return to repair center.
07Overload time out.Reduce connected load.
08Bus voltage is too high.Return to repair center.
09Bus soft start failed.Return to repair center.
51Over current or surge.Restart unit. If error persists, return to repair center.
52Bus voltage is too low.Restart unit. If error persists, return to repair center.
53Inverter soft start failed.Restart unit. If error persists, return to repair center.
55Over DC voltage in AC output.Restart unit. If error persists, return to repair center.
57Current sensor failed.Restart unit. If error persists, return to repair center.
58Output voltage is too low.Restart unit. If error persists, return to repair center.
59PV voltage is over limitation.Restart unit. If error persists, return to repair center.

7.2 Warning Indicator

Warning CodeWarning EventAudible Alarm
01Fan is locked when inverter is on.Beep three times every second.
03Battery is over-charged.Beep once every second.
04Low battery.Beep once every second.
07Overload.Beep once every 0.5 second.
10Output power derating.Beep twice every 3 seconds.
15PV energy is low.Beep twice every 3 seconds.
E9Battery equalization.None.

8. Specifications

8.1 Line Mode Specifications

INVERTER MODEL2.0KVA-12V3.2KVA-24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

8.2 Inverter Mode Specifications

INVERTER MODEL2.0KVA-12V3.2KVA-24V
Rated Output Power2000VA/1600W3200VA/3000W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency94%
Overload Protection5s@ >150% load; 10s@ 100% ~ 150% load
Surge Capacity2 * rated power for 5 seconds
Nominal DC Input Voltage12Vdc24Vdc
Cold Start Voltage11.5Vdc23.0Vdc
Low DC Warning Voltage (@load < 50%)11.0Vdc22.0Vdc
Low DC Warning Voltage (@load > 50%)10.5Vdc21.0Vdc
Low DC Warning Return Voltage (@load < 50%)11.5Vdc22.5Vdc
Low DC Warning Return Voltage (@load > 50%)11.0Vdc22.0Vdc
Low DC Cut-off Voltage (@load < 50%)10.2Vdc20.5Vdc
Low DC Cut-off Voltage (@load > 50%)9.6Vdc20.0Vdc
High DC Recovery Voltage14.0Vdc32Vdc
High DC Cut-off Voltage16.0Vdc33Vdc
No Load Power Consumption<25W<35W

8.3 Charge Mode Specifications

INVERTER MODEL2.0KVA-12V3.2KVA-24V
Utility Charging Mode
Charging Algorithm3-Step
AC Charging Current (Max)60Amp (@V I/P= 230Vac)60Amp (@V I/P= 230Vac)
Bulk Charging Voltage (Flooded Battery)14.629.2
Bulk Charging Voltage (AGM / Gel Battery)14.128.2
Floating Charging Voltage13.5Vdc27Vdc
MPPT Solar Charging Mode
Max. PV Array Power2000W3000W
Nominal PV Voltage240Vdc
PV Array MPPT Voltage Range30~400Vdc
Max. PV Array Open Circuit Voltage400Vdc
Max Charging Current (AC charger plus solar charger)80Amp

8.4 General Specifications

INVERTER MODEL2.0KVA-12V3.2KVA-24V
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage Temperature-15°C ~ 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D * W * H), mm357X273X95
Net Weight, kg4.64.8

9. User Tips

  • Battery Compatibility: This inverter is compatible with various battery types, including Lithium-ion, Flooded, Gel, Lead-acid, and AGM batteries. Ensure the correct battery type is selected in the LCD settings (Program 05) for optimal performance and charging.
  • Operation Without Battery: The inverter can function with photovoltaic panels only, without a battery connected, to supply power directly. It can also generate 230V output even without a battery connected, provided there is sufficient PV input or AC input.
  • WIFI Monitoring: If your model includes WIFI functionality, ensure the WIFI module is properly installed (it may be optional and not included in the standard package). Refer to the manual for instructions on how to activate and monitor your system via WIFI.
  • Solar Panel Configuration: For optimal performance, ensure your solar panels are configured correctly. For example, two 505W, 35V panels can be connected in series, provided the total voltage and current remain within the inverter's specified MPPT range (30-400VDC).
  • AC Source Connection: While the inverter can operate in various modes, connecting an AC source (utility or generator) provides additional charging capabilities and ensures continuous power supply, especially when solar input is insufficient.
  • Zero Export to Grid: For users interested in zero export to the grid, check the advanced settings or consult the full PDF manual for specific adjustments related to grid interaction.
  • Battery Capacity Settings: You can set high and low limits and delays for battery capacity in the LCD settings to control when the battery is connected to the inverter, optimizing battery life and system performance.

10. Warranty and Support

All PowMr products typically come with a 1-year warranty from the store. For any issues or support, please contact the seller or manufacturer directly.

10.1 Manufacturer Contact Information

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

For further detailed information, including advanced settings and comprehensive diagrams, please refer to the official user manual PDF available at: PowMr Hybrid Solar Inverter User Manual (PDF)