1. Product Overview
The JIKONG JK-B2A8S20P Smart BMS (Battery Management System) is an intelligent protection board designed for large-capacity series lithium battery packs. It offers comprehensive management and protection features to ensure the safety and longevity of your battery system.
Key features include voltage acquisition, high-current active balancing, overcharge/over-discharge protection, overcurrent/over-temperature protection, coulomb meter, Bluetooth communication, and optional GPS and remote functions. This BMS is compatible with Li-ion, LiFePO4, and LTO battery types.
The protection board utilizes energy transfer active balancing technology with a continuous balancing current of 1A/2A, which significantly improves battery consistency, extends battery range, and delays aging. It is operated via a mobile APP available for both Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches.
The compact design and full functionality make it suitable for various applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage, base station backup power, and solar power stations.

2. Specifications
2.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 7.5-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30-70 | °C |
| Maximum Number of Collection Strings | 8 | String |
| Maximum Balancing Current | 1A / 2A | A |
| Maximum Charging Current | 200 | A |
| Maximum Discharge Current | 200 | A |
| Maximum Instantaneous Current | 400 | A |
| Maximum Internal Loop Resistance | 0.35 | mΩ |
| Protective Plate Size | 152.25 × 127.26 × 15.6 | mm |
| Finished Weight | 424 | g |
| Certifications | CE, FCC, RoHS |
2.2. Default Parameters (Example for LiFePO4)
| Parameter | LiFePO4 Default | Unit |
|---|---|---|
| Balancing Initial Voltage | 3 | V |
| Single Overcharge Voltage | 3.6 | V |
| Single Overcharge Protection Recovery | 3.55 | V |
| Monomer Undervoltage Protection | 2.6 | V |
| Monomer Undervoltage Protection Recovery | 2.65 | V |
| Automatic Shutdown Voltage | 2.5 | V |
| Trigger Balancing Differential Pressure | 0.01 | V |
| Charging Overtemperature Protection | 70 | °C |
| Charging Low Temperature Protection | -20 | °C |
| Short-circuit Protection Delay | 5 | µS |
3. Setup and Installation
3.1. Package Contents
Before installation, please verify that all components are present:

3.2. Wiring Diagram
The JK-B2A8S-20P series protection board is suitable for 3-8 series lithium battery packs. The wiring method varies depending on the number of cells in your battery pack. Always ensure correct connections to prevent damage.

3.3. Interface Definition
The BMS board features various ports for different functionalities:

A detailed pinout for the connectors is provided in the full user manual (PDF).
3.4. Device Activation
Before powering on the protection board, perform the following checks:
- Verify that the balance cable is properly connected.
- Ensure that the P- (charger/load negative) and B- (battery negative) connections are correct.
- Confirm that the protection board is securely fixed to the battery pack.
After confirming these steps, power on the protection board. The BMS does not have a power-on control switch and is designed for charging activation. This means the charger voltage must be at least 2V higher than the battery voltage to activate the BMS. Alternatively, the BMS can be activated via a display activation button or an additional switch if equipped.
4. Operation
4.1. APP Installation and Connection
The JIKONG BMS is controlled via a mobile application. To install the APP:
- For iOS: Search for "JIKONG BMS" in the APP STORE.
- For Android: Search for "JK BMS" in the Google STORE. Android Version 7 or higher is required.

To connect the APP to the BMS:
- Ensure Bluetooth is enabled on your mobile phone.
- Open the APP, click on the top left corner to search for devices.
- Select your device name to connect. The default password is 1234.
4.2. Smart Energy Working Modes
The BMS supports different working modes to optimize battery performance and longevity:

- Storage Mode: In transportation, offline, or wireless transmission off mode, the BMS enters storage mode, which does not consume battery pack current.
- Normal Working Mode: When the charger is inserted in storage mode and then removed, the BMS immediately returns to normal working mode, and all protection, equalization, and communication functions resume.
- Shutdown: To prevent power waste and battery damage during long periods of inactivity, the BMS has an automatic shutdown voltage. It automatically shuts down when a cell falls below this voltage.
- Standby Mode: When the battery pack is in a static state (no charge/discharge current and no equilibrium current), the BMS automatically enters standby mode after a set time (1-30 days, configurable).
4.3. Active Balancing
The active balancing feature transfers energy from high-voltage cells to low-voltage cells to maintain battery consistency. Users can set the balance trigger pressure difference (mV) in the APP. Balancing automatically activates when the difference between any two strings exceeds the set value and turns off when it falls below. The default balance current is 1A/2A, adjustable based on battery capacity (recommended not to exceed 0.2C of battery capacity). This function can be toggled on/off in the APP's BMS control page.
4.4. Heating Function (Optional)
For models with the heating function, the BMS can heat the battery at low temperatures using a resistance heater or heating film. This prevents charging/discharging issues due to reduced battery activity in cold conditions. The heating current is 20A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary safety measure.
4.5. Parallel Function (Optional)
The BMS supports battery pack parallel functionality for energy storage applications. This requires synchronous use with parallel modules. Ensure the "disable charging current limiting" function is turned off in the APP when using this feature.
4.6. ACC Detection Function (Optional)
This function enables discharge. It can be achieved by applying a voltage (20V-100V) between ACC+ and ACC- or by directly short-circuiting them. A charger detection function (C_detect+ and C_detect-) is also available for enabling charging.
4.7. Communication Functions (Optional)
The BMS supports optional CAN and RS485 communication. Users can select CAN or RS485 for multiplexed ports on the APP's BMS control page. Address and communication protocols can be configured based on requirements. Refer to the Jikong Protection Board communication protocol document for specific details.
4.8. Intelligent Sleep
The intelligent sleep function reduces the BMS's power consumption when the battery is in standby (charging/discharging current less than 1A for 26 consecutive hours). Users can enable or disable this function via the APP. To reactivate the BMS from sleep, use the button or connect a charger.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your JIKONG Smart BMS. This includes:
- Connection Checks: Periodically inspect all wiring connections (balance cables, P-, B-, etc.) to ensure they are secure and free from corrosion. Loose connections can lead to inaccurate readings or system malfunctions.
- Cleanliness: Keep the BMS board clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning.
- Software Updates: Check for updates to the JIKONG BMS mobile application to ensure you have the latest features and bug fixes.
- Parameter Review: Occasionally review the BMS parameters in the APP to ensure they are still appropriate for your battery configuration and usage patterns.
6. Troubleshooting
If you encounter issues with your JIKONG Smart BMS, refer to the following common problems and solutions:
6.1. Common Issues and Solutions
- BMS Does Not Turn On:
- Ensure the last "B+" line of the balance cable is connected to the positive pole of the battery.
- Start up after charging, ensuring the charger voltage is at least 4V higher than the battery pack voltage.
- Check if the charger has voltage output.
- Inaccurate Voltage Readings:
- Measure the actual total voltage of the battery pack with a multimeter.
- Enter this actual total voltage into the "voltage calibration" section on the APP's parameter setting page.
- Inaccurate Current Readings:
- Ensure that both B- and P- of the protection board are connected using two 7AWG wires in parallel. Incorrect wiring can lead to current errors.
- Measure the actual current of the battery pack with a clamp meter.
- Enter this actual current into the "current calibration" section on the APP's parameter setting page. Higher actual current during calibration generally leads to higher accuracy.
- Inaccurate Capacity Readings:
- The initial capacity estimated by the BMS when first powered on is often inaccurate.
- For accurate calibration, fully discharge the battery pack to its cut-off voltage, then fully charge it without interruption. The capacity will be calibrated during this process.
- Inconsistent Designed String Number with Actual String Number:
- Verify that the "unit quantity" (number of cells) is correctly set in the APP's parameter settings.
- If there is no voltage in two or more strings in the middle of the pack, check if the acquisition cable has come loose or is damaged.
6.2. Protection Features
The BMS includes several protection mechanisms to safeguard your battery:

- Overcharge Protection & Recovery: Prevents over-charging. The BMS will shut off charging if any cell voltage exceeds the set overcharge protection voltage. Charging resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection & Recovery: Prevents over-discharging. Discharge is cut off if any cell voltage falls below the set undervoltage protection voltage. Discharge resumes when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell falls below the automatic shutdown voltage.
- Overcurrent Protection & Recovery (Charge/Discharge): Prevents current from exceeding safe limits. If the current exceeds the set continuous current for a specified delay, the BMS will cut off charge/discharge. It recovers after a set time.
- Overtemperature Protection & Recovery (Charge/Discharge): Prevents damage from high temperatures. Charge/discharge is cut off if the temperature exceeds the set limit and resumes when it falls below the recovery temperature.
- Low Temperature Protection & Recovery (Charge): Prevents charging in cold conditions. Charging is cut off if the temperature falls below the set limit and resumes when it rises above the recovery temperature.
- Short Circuit Protection & Recovery: Automatically protects against short circuits. The BMS will cut off power if a short circuit is detected. Delay and recovery times are configurable.
- Alarm Function: The BMS supports an optional alarm function to alert users to safety risks such as overtemperature, overcharge, or overdischarge.
- Emergency Switch: In case of critical issues (over-temperature, over-discharge, over-charge, cell drop), activating the emergency switch via the APP provides 30 minutes of operation, allowing for safe handling of the situation.
7. User Tips
- Initial Setup: Always double-check all wiring connections, especially the B+ and B- terminals, before powering on the BMS for the first time.
- APP Connectivity: Users have reported good connectivity with the mobile app. Ensure your phone's Bluetooth is on and you're within range for reliable monitoring.
- Parameter Customization: Take advantage of the APP to customize parameters like balancing current, voltage thresholds, and temperature limits to perfectly match your specific battery type and application.
- Package Contents: The package typically includes all necessary cables and a switch, as confirmed by other users.
8. Warranty and Support
For detailed warranty information and further technical support, please refer to the official user manual PDF. This document provides comprehensive details on product usage, specifications, and troubleshooting beyond the scope of this summary.
User Manual (PDF): A detailed user manual in PDF format is available for download. This manual contains in-depth information on parameter settings, interface definitions, and advanced functionalities.
You can access the official user manual PDF here: JIKONG JK-BxA8S-20P User Manual (PDF)