1. Introduction
This manual provides essential information for the installation, operation, and maintenance of your SUMRY Hybrid Solar Inverter SP Series. This multi-function inverter/charger combines the functions of an inverter, MPPT solar charger, and battery charger to offer uninterruptible power support in a portable size. It is designed to provide reliable power for various applications, utilizing solar power, battery power, and utility grid power.
2. Key Features
- Pure sine wave inverter output.
- Programmable supply priority for PV, battery, or Grid.
- High PV input voltage range (55-450VDC).
- Built-in Max 110A MPPT solar charge controller (for 3.6KW & 6.2KW models).
- Compatible with lithium-ion batteries.
- Supports BMS communication with lithium batteries.
- Smart battery charge design to optimize battery life.
- Comprehensive protection against overload, high temperature, and inverter output short circuit.
- Cold start function for reliable operation.
- Intelligent fan speed adjustment for efficient cooling.
- WIFI & GPRS available for iOS and Android monitoring (optional).
3. Specifications
The following table details the specifications for the SP-7000 model:
| Category | Parameter | SP-7000 (6.2KW) |
|---|---|---|
| Input | Voltage | 230VAC |
| Selectable Voltage Range | 170-280VAC (for personal computers) 90-280VAC (for home appliances) | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| Output | Rated Power | 7000VA/6200W |
| AC Voltage Regulation (Batt.Mode) | 230VAC±5% | |
| Surge Power | 14000VA | |
| Wave form | Pure Sine Wave | |
| Battery & AC Charger | Battery Voltage | 48V |
| Floating Charge Voltage | 54VDC | |
| Overcharge Protection | 61VDC | |
| Maximum Charge Current | 80A | |
| Solar Charger | MAX. PV Array Power | 6000W |
| MPPT Range@Operating Voltage | 55-450VDC | |
| Maximum PV Array Open Circuit Voltage | 450VDC | |
| Maximum Charging Current | 110A | |
| Physical | Dimension D*W*H(mm) | 423*310*106mm |
| Net Weight (kgs) | 8.0kg | |
| Communication Interface | RS232/RS485 (Standard) GPRS/WIFI (Optional) | |
| Maximum Efficiency | 98% | |
| Output Type | SINGLE | |
| Operating Environment | Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature | -10°C to 55°C | |
| Storage Temperature | -15°C to 60°C |
Note: Ensure the power rating is higher than the appliance you want to apply. You should purchase a larger model (at least 10% to 20% more than the maximum load). If you want to run more than one appliance at the same time, you should refer to the total wattage. To run inductive loads for a long time, you should buy a pure sine wave inverter.
4. Product Overview
Familiarize yourself with the components and controls of your inverter.

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons (ESC, UP, DOWN, ENTER)
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- RS-232 communication port
- Safety (Earth) ground
- Circuit breaker
5. Mounting the Unit
Consider the following points before selecting where to install the inverter:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
6. Wiring and Connections
Proper wiring is crucial for safe and efficient operation. Refer to the diagrams below for correct connections.
6.1. Battery Connection
Connect all battery packs as shown in the chart. Note that 1.8KW models support 12VDC systems, and 3KW models support 24VDC systems. For the 6.2KW model, a 48VDC system is required.

6.2. System Diagram
The inverter supports operation with or without a battery connected, depending on solar power and AC power availability. The system can power loads from PV energy, the battery, or the grid.

Operation with battery connected: Solar power and AC power are available. The inverter prioritizes solar, then battery, then grid.
Solar Power and AC Power not available: The inverter can still power loads from the battery or generator if connected.
Video: Product Connections and Usage Demonstration
This video demonstrates the unboxing, connection of PV input, AC input/output, and battery terminals, and powering various household appliances like a fan, kettle, smartphone, and laptop using the inverter.
7. Operating Instructions
7.1. Operation and Display Panel
The inverter features an LCD display, LED indicators, and function keys for monitoring and control.

| LED Indicator | Color | Messages |
|---|---|---|
| AC / INV | Green | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG | Green | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| FAULT | Red | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
7.2. LCD Function Description
The LCD provides detailed information about the inverter's status and operation.

- PV input
- AC input
- Input voltage, input frequency, PV voltage, battery voltage, charger current
- Setting programs
- Flashing with warning code, lighting with fault code
- Output voltage, output frequency, load percent, load in VA, load in watt and discharging current
- Load level
- DC/AC inverter circuit is working
- Battery level
- Utility charger circuit is working
- Unit connects to the PV panel
- Unit connects to the mains
- Load is supplied by utility power
- Unit alarm is disabled
- Overload
8. User Tips
- This inverter model (SP-7000) requires a battery to function. It cannot operate without a battery connected.
- The maximum PV array power supported is 6000W. When connecting 550W solar panels, you can connect approximately 10-11 panels (6000W / 550W ≈ 10.9). Always ensure the total wattage and voltage of your solar array remain within the inverter's specified limits.
- The inverter provides an AC output of 220-240V. If you need to power 110VAC equipment, a separate step-down transformer (220V to 110V) will be required.
- For optimal performance and longevity, ensure the inverter is installed in a well-ventilated area with adequate clearance for heat dissipation.
9. Troubleshooting
This section provides solutions to common issues you might encounter with your inverter.
9.1. Common Issues and Solutions
- Inverter not turning on: Check battery connections, ensure the power switch is on, and verify battery voltage is within the operating range.
- No AC output: Check AC output connections, ensure no overload condition, and verify the inverter is not in fault mode (check FAULT LED).
- Battery not charging: Verify PV input connections and voltage, check AC input if charging from grid, and ensure the CHG LED is flashing or solid.
- Overload warning/fault: Reduce the connected load. The inverter has overload protection.
- High temperature warning/fault: Ensure adequate ventilation around the inverter. Check for blocked vents or insufficient clearance.
If the issue persists after attempting these solutions, please contact customer support.
10. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter and ensure ventilation openings are free from dust and debris. Use a dry cloth; do not use liquids.
- Connection Inspection: Regularly check all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion.
- Environmental Check: Ensure the installation environment remains within the specified temperature and humidity ranges.
- Battery Health: Monitor battery health and charge levels, especially for lead-acid batteries, to maximize their lifespan.
Always disconnect all power sources before performing any maintenance.
11. Safety Precautions
- Read all instructions and cautionary markings on the unit and in this manual before installation and operation.
- Do not disassemble the inverter. There are no user-serviceable parts inside. Refer servicing to qualified personnel.
- Ensure all wiring is performed by a qualified electrician and complies with local electrical codes.
- Do not install the inverter in direct sunlight, near heat sources, or in areas with excessive moisture or flammable materials.
- Always wear appropriate personal protective equipment (PPE) when working with electrical systems.
- Ensure proper grounding of the inverter.
- Keep children away from the inverter and its connections.
12. Warranty and Support
Your SUMRY Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use conditions.
For technical assistance, troubleshooting, or warranty claims, please contact the SUMRY Official Store's professional engineer team. They are available to answer and solve your problems during pre-sale and after-sale periods.