1. Introduction and Overview

The SUMRY HGX Series 4KW Off-Grid MPPT Solar Hybrid Inverter is a versatile power solution designed to provide reliable, clean, and quiet AC energy for various applications, including home, office, and outdoor environments. This inverter features a pure sine wave output, a built-in MPPT solar charger, and the ability to operate without a battery, making it suitable for diverse off-grid setups.

SUMRY HGX Series 4KW Off-Grid MPPT Solar Hybrid Inverter front view
Front view of the SUMRY HGX Series 4KW Off-Grid MPPT Solar Hybrid Inverter, highlighting its key features.

Key features include:

  • 4KW Rated Power
  • 100/110/120VAC Input Voltage
  • 120VAC±5% AC Output Voltage
  • 110A Max. Charge Current
  • 5.6KW Max. PV Array Power
  • 55-280VDC MPPT Range @ Voltage
  • RS232/RS485 (standard) communication ports
  • LCD remote/Wi-Fi (optional) monitoring
  • Pure Sine Wave output
  • Ability to work without a battery (SBU mode: utility power, battery, and PV power complement each other)
  • Unique glass top cover design with 6.25-inch LCD display and touchable buttons
  • Smart battery charger design for optimized battery performance
  • Configurable AC/Battery input priority via LCD setting
  • Cold restart function
SUMRY HGX Series Inverter features overview
Overview of the inverter's features including silent fan, MPPT SCC, LCD display, touch buttons, tempered glass, optional WiFi, pure sine wave, and SBU mode.

2. Safety Information

Please read and understand all safety instructions before installing, operating, or servicing this inverter. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • All wiring must be performed by qualified personnel.
  • Ensure proper cable sizes are used for all connections to reduce risk of injury and ensure system safety and efficient operation.
  • Do not attempt to disassemble or repair the inverter yourself. Refer all servicing to qualified service personnel.
  • Keep the inverter away from flammable materials and ensure adequate ventilation to prevent overheating.
  • This inverter is designed for indoor use. Avoid exposure to rain, snow, or excessive moisture.
  • Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
Inverter protection features
The inverter includes multiple protection features: Overload Protection, Overheating Protection, High/Low Voltage Protection, Battery Protection, Short Circuit Protection, Overcurrent Protection, Anti-Reverse Protection, and Power Failure Protection.

3. Specifications

Refer to the table below for detailed technical specifications of the HGX 4KW inverter model.

SUMRY HGX Series 4KW Inverter Specifications Table
Detailed specifications for the 4000W inverter model.
HGX 4KW Inverter Specifications
FeatureSpecificationFeatureSpecification
Inverter Model4000WMax. PV Array Power5600W
Voltage100/110/120VACMPPT Voltage Range55-280VDC
Frequency Range50Hz/60HzMax. MPPT Efficiency99%
AC Output Voltage120VAC±5%Grid Nominal Output Voltage120Vac
Wave formPure Sine WaveDimension (D*W*H)400*250*89mm
Battery Voltage24VDCNet Weight8.5Kg
Max. charge current110ACommunication InterfaceRS485/RS232 (standard), LCD remote/WIFI (Optional)

The inverter is compatible with multiple battery types:

  • FLD (Flooded)
  • GEL (Gel)
  • LI (Lithium-iron phosphate)
  • LI (Lithium-ion)
  • SLD (AGM/Sealed)
  • USER (User custom Battery)
Battery compatibility types for the inverter
Diagram illustrating the various battery types compatible with the inverter.

4. Setup and Installation

WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

4.1 System Connection Diagram

General system connection diagram for SUMRY HGX Inverter
This diagram illustrates how the inverter connects to solar modules, a photovoltaic box, a generator, the utility grid, battery packs, and various home appliances, including optional Wi-Fi.

The inverter can be connected to various power sources and loads:

  • Solar Modules: Connect to the PV input terminals.
  • Generator: Can be used as an alternative AC input source.
  • Utility Grid: Provides AC input and can charge batteries.
  • Battery Packs: Connect to the battery input terminals.
  • Home Appliances: Connect to the AC output terminals.
Back panel connections of the inverter
Detailed view of the inverter's back panel connections: Battery input, AC output, RS485/RS232 communication port, AC input, PV input.

4.2 PV Connection

Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. PV Array MPPT Voltage range.
Solar panel series connection guide
Diagram showing how to connect solar panels in series to achieve the required voltage. Ensure total power does not exceed the inverter's maximum power.

Connecting solar panels in series will increase the voltage. This voltage needs to be between the inverter's PV voltage range (55-280VDC). Check the open circuit voltage of your solar panels first.

Please make sure that the total power of solar panels does not exceed the maximum power of the inverter (Loads < Inverter power).

Recommended PV cable dimensions: 6-8 mm².

PV Connection Wire Size and Torque Values
ModelWire SizeCable (mm²)Torque value (max)
3.0KW/4.0KW1 x 12AWG41.2 Nm
PV Module Selection Parameters
Inverter ModelMax. PV Array Open Circuit VoltagePV Array MPPT Voltage Range
3.0KW350Vdc55Vdc~280Vdc
4.0KW350Vdc55Vdc~280Vdc

Watch this video for a visual guide on unboxing and connecting the inverter:

Video demonstrating the unboxing and initial wiring of the SUMRY HGX Series Inverter, including connecting to a power strip for appliances.

5. Operating Instructions

The inverter features a 6.25-inch LCD display and touch buttons for easy operation and monitoring.

5.1 LCD Display and Indicators

Inverter LCD display and LED indicators
Diagram showing the LCD display, charging indicator, status indicator, fault indicator, and function touch buttons.
LED Indicator Messages
LED IndicatorMessages
AC/INV (Green Solid On)Output is powered by utility in Line mode.
AC/INV (Green Flashing)Output is powered by battery or PV in battery mode.
CHG (Green Solid On)Battery is fully charged.
CHG (Green Flashing)Battery is charging.
FAULT (Red Solid On)Fault occurs in the inverter.
FAULT (Red Flashing)Warning condition occurs in the inverter.

5.2 Function Keys

Function Key Descriptions
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5.3 Wi-Fi Monitoring (Optional)

The inverter supports Wi-Fi monitoring via the Smartess App (optional Wi-Fi module required). This allows you to monitor and control your inverter remotely.

Smartess App for Wi-Fi monitoring
Screenshot of the Smartess App interface for remote monitoring and control of the inverter.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SUMRY HGX Series Inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure ventilation openings are free from dust and debris.
  • Connections: Regularly check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
  • Environment: Ensure the inverter is installed in a well-ventilated area, free from direct sunlight, excessive heat, moisture, and corrosive substances.
  • Battery Health: If using batteries, monitor their health and charge levels according to the battery manufacturer's recommendations.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for your inverter model to ensure you have the latest features and bug fixes.

Caution: Always disconnect all power sources before performing any cleaning or maintenance to avoid electric shock.

7. Troubleshooting

This section provides guidance on common issues you might encounter with your inverter. For more complex problems, contact customer support.

  • No Power Output:
    • Check all input power sources (PV, battery, AC utility/generator) are connected and supplying power.
    • Verify that the inverter's ON/OFF switch is in the 'ON' position.
    • Check for any fault indicators on the LCD display or LED panel.
    • Ensure all circuit breakers are not tripped.
  • Low Power Output:
    • Inspect solar panels for shading or dirt.
    • Verify battery charge level if operating in battery mode.
    • Check PV array voltage is within the MPPT range (55-280VDC).
  • Fault Indicator On:
    • Refer to the LED Indicator Messages table in Section 5.1 to identify the type of fault or warning.
    • Common faults include overload, overheating, high/low voltage, and battery issues. Address the underlying cause as indicated.
    • If the fault persists after addressing the issue, contact technical support.
  • Wi-Fi Monitoring Issues:
    • Ensure the optional Wi-Fi module is correctly installed.
    • Verify your Wi-Fi network is active and the inverter is within range.
    • Check the Smartess App for connection status and troubleshooting tips.

8. User Tips

  • Battery-Free Operation: This inverter supports operation without a battery, relying solely on solar panels and/or utility/generator input. This can simplify your setup and reduce initial costs.
  • Optional Wi-Fi Module: For remote monitoring and control, consider purchasing the optional Wi-Fi module. This allows you to manage your inverter settings and view performance data via the Smartess App.
  • PV Panel Sizing: When connecting solar panels, ensure the total open circuit voltage (Voc) of your series-connected panels does not exceed the inverter's maximum PV array open circuit voltage (350Vdc for 4KW model) and stays within the MPPT voltage range (55-280Vdc). Also, ensure the total power of your solar panels does not exceed the inverter's maximum power rating.

9. Warranty and Support

The SUMRY HGX Series Inverter comes with a 1-year warranty. For warranty claims, technical support, or service inquiries, please contact your vendor or the SUMRY customer service directly.

Please have your product model number (HGX 4KW) and purchase information ready when contacting support.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.