1. Introduction and Overview
The SUMRY HGX Series 4KW Off-Grid MPPT Solar Hybrid Inverter is a versatile power solution designed to provide reliable, clean, and quiet AC energy for various applications, including home, office, and outdoor environments. This inverter features a pure sine wave output, a built-in MPPT solar charger, and the ability to operate without a battery, making it suitable for diverse off-grid setups.

Key features include:
- 4KW Rated Power
- 100/110/120VAC Input Voltage
- 120VAC±5% AC Output Voltage
- 110A Max. Charge Current
- 5.6KW Max. PV Array Power
- 55-280VDC MPPT Range @ Voltage
- RS232/RS485 (standard) communication ports
- LCD remote/Wi-Fi (optional) monitoring
- Pure Sine Wave output
- Ability to work without a battery (SBU mode: utility power, battery, and PV power complement each other)
- Unique glass top cover design with 6.25-inch LCD display and touchable buttons
- Smart battery charger design for optimized battery performance
- Configurable AC/Battery input priority via LCD setting
- Cold restart function

2. Safety Information
Please read and understand all safety instructions before installing, operating, or servicing this inverter. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- All wiring must be performed by qualified personnel.
- Ensure proper cable sizes are used for all connections to reduce risk of injury and ensure system safety and efficient operation.
- Do not attempt to disassemble or repair the inverter yourself. Refer all servicing to qualified service personnel.
- Keep the inverter away from flammable materials and ensure adequate ventilation to prevent overheating.
- This inverter is designed for indoor use. Avoid exposure to rain, snow, or excessive moisture.
- Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.

3. Specifications
Refer to the table below for detailed technical specifications of the HGX 4KW inverter model.

| Feature | Specification | Feature | Specification |
|---|---|---|---|
| Inverter Model | 4000W | Max. PV Array Power | 5600W |
| Voltage | 100/110/120VAC | MPPT Voltage Range | 55-280VDC |
| Frequency Range | 50Hz/60Hz | Max. MPPT Efficiency | 99% |
| AC Output Voltage | 120VAC±5% | Grid Nominal Output Voltage | 120Vac |
| Wave form | Pure Sine Wave | Dimension (D*W*H) | 400*250*89mm |
| Battery Voltage | 24VDC | Net Weight | 8.5Kg |
| Max. charge current | 110A | Communication Interface | RS485/RS232 (standard), LCD remote/WIFI (Optional) |
The inverter is compatible with multiple battery types:
- FLD (Flooded)
- GEL (Gel)
- LI (Lithium-iron phosphate)
- LI (Lithium-ion)
- SLD (AGM/Sealed)
- USER (User custom Battery)

4. Setup and Installation
WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
4.1 System Connection Diagram

The inverter can be connected to various power sources and loads:
- Solar Modules: Connect to the PV input terminals.
- Generator: Can be used as an alternative AC input source.
- Utility Grid: Provides AC input and can charge batteries.
- Battery Packs: Connect to the battery input terminals.
- Home Appliances: Connect to the AC output terminals.

4.2 PV Connection
Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. PV Array MPPT Voltage range.

Connecting solar panels in series will increase the voltage. This voltage needs to be between the inverter's PV voltage range (55-280VDC). Check the open circuit voltage of your solar panels first.
Please make sure that the total power of solar panels does not exceed the maximum power of the inverter (Loads < Inverter power).
Recommended PV cable dimensions: 6-8 mm².
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.0KW/4.0KW | 1 x 12AWG | 4 | 1.2 Nm |
| Inverter Model | Max. PV Array Open Circuit Voltage | PV Array MPPT Voltage Range |
|---|---|---|
| 3.0KW | 350Vdc | 55Vdc~280Vdc |
| 4.0KW | 350Vdc | 55Vdc~280Vdc |
Watch this video for a visual guide on unboxing and connecting the inverter:
5. Operating Instructions
The inverter features a 6.25-inch LCD display and touch buttons for easy operation and monitoring.
5.1 LCD Display and Indicators

| LED Indicator | Messages |
|---|---|
| AC/INV (Green Solid On) | Output is powered by utility in Line mode. |
| AC/INV (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
5.2 Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 Wi-Fi Monitoring (Optional)
The inverter supports Wi-Fi monitoring via the Smartess App (optional Wi-Fi module required). This allows you to monitor and control your inverter remotely.

6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your SUMRY HGX Series Inverter.
- Cleaning: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure ventilation openings are free from dust and debris.
- Connections: Regularly check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
- Environment: Ensure the inverter is installed in a well-ventilated area, free from direct sunlight, excessive heat, moisture, and corrosive substances.
- Battery Health: If using batteries, monitor their health and charge levels according to the battery manufacturer's recommendations.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for your inverter model to ensure you have the latest features and bug fixes.
Caution: Always disconnect all power sources before performing any cleaning or maintenance to avoid electric shock.
7. Troubleshooting
This section provides guidance on common issues you might encounter with your inverter. For more complex problems, contact customer support.
- No Power Output:
- Check all input power sources (PV, battery, AC utility/generator) are connected and supplying power.
- Verify that the inverter's ON/OFF switch is in the 'ON' position.
- Check for any fault indicators on the LCD display or LED panel.
- Ensure all circuit breakers are not tripped.
- Low Power Output:
- Inspect solar panels for shading or dirt.
- Verify battery charge level if operating in battery mode.
- Check PV array voltage is within the MPPT range (55-280VDC).
- Fault Indicator On:
- Refer to the LED Indicator Messages table in Section 5.1 to identify the type of fault or warning.
- Common faults include overload, overheating, high/low voltage, and battery issues. Address the underlying cause as indicated.
- If the fault persists after addressing the issue, contact technical support.
- Wi-Fi Monitoring Issues:
- Ensure the optional Wi-Fi module is correctly installed.
- Verify your Wi-Fi network is active and the inverter is within range.
- Check the Smartess App for connection status and troubleshooting tips.
8. User Tips
- Battery-Free Operation: This inverter supports operation without a battery, relying solely on solar panels and/or utility/generator input. This can simplify your setup and reduce initial costs.
- Optional Wi-Fi Module: For remote monitoring and control, consider purchasing the optional Wi-Fi module. This allows you to manage your inverter settings and view performance data via the Smartess App.
- PV Panel Sizing: When connecting solar panels, ensure the total open circuit voltage (Voc) of your series-connected panels does not exceed the inverter's maximum PV array open circuit voltage (350Vdc for 4KW model) and stays within the MPPT voltage range (55-280Vdc). Also, ensure the total power of your solar panels does not exceed the inverter's maximum power rating.
9. Warranty and Support
The SUMRY HGX Series Inverter comes with a 1-year warranty. For warranty claims, technical support, or service inquiries, please contact your vendor or the SUMRY customer service directly.
Please have your product model number (HGX 4KW) and purchase information ready when contacting support.