1. Introduction
This manual provides essential information for the safe and effective use of the YHDC PE3013-M 1.9VA Encapsulated Safety Isolating Transformer. Please read this manual thoroughly before installation and operation to ensure proper functionality and safety.

2. Product Features
The YHDC PE3013-M transformer is designed with advanced technology and high-quality materials, offering reliable performance for various power applications. Key features include:
- Encapsulation: Vacuum epoxy resin encapsulated for durability, high temperature aging resistance (100°C / 6 hours), and a long working life of 20 years with high dielectric strength.
- Core Material: Utilizes high-quality H18 laminated silicon steel for low temperature rise and high efficiency.
- Housing: Made from PBT engineering plastic, which is environmentally friendly, flame retardant, and maintains its shape up to 120 degrees Celsius.
- Design: Features a reasonable structure for convenient installation, low noise operation, strong seismic resistance, and is sealed for waterproof and moisture-proof protection.
- Coil: Adopts single crystal copper enamelled wire.
- Manufacturing Process: Encapsulated using a German epoxy resin vacuum process, ensuring improved heat conduction to the housing and a uniform heat gradient.

3. Technical Specifications
Below are the detailed technical specifications for the PE3013-M transformer:
| Parameter | Value |
|---|---|
| Mounting Type | PCB |
| Flame Resistance | UL94-V0 |
| Insulation Class | B |
| Operation Temperature | -30°C ~ +70°C |
| Work Frequency | 50Hz ~ 60Hz |
| Dielectric Strength (Pri./Sec.) | 3.75KV 50Hz 1min 5mA |
| Dielectric Strength (Sec./Sec.) | 500V 50Hz 1min 5mA |
| Primary Voltage | 110V/220V/230V/380V |
| Primary Voltage Range | ±10% |
| Voltage Regulation | ≤32% |
| Power | 1.9 VA |
| Temperature Rise | ≤15°C |
| No-load Loss | ≤0.4 W |
| Weight | 79 g |
| Dimensions (L x W x H) | 32.5mm x 27.5mm x 23.9mm (±0.5mm) |
Standard Output Parameter Table (Factory test is based on full-load voltage)
| Secondary Voltage | Secondary No-load Voltage | Secondary Full-load Current | ||
|---|---|---|---|---|
| Single | Double | Single | Double | |
| 6V | 8V | 2×8V | 317mA | 2×158mA |
| 7.5V | 10.5V | 2×10.5V | 253mA | 2×127mA |
| 9V | 12.5V | 2×12.5V | 211mA | 2×106mA |
| 12V | 16.5V | 2×16.5V | 158mA | 2×79mA |
| 15V | 21.5V | 2×21.5V | 127mA | 2×63mA |
| 18V | 26V | 2×26V | 106mA | 2×53mA |
| 24V | 33V | 2×33V | 79mA | 2×40mA |

4. Setup and Installation
The PE3013-M transformer is designed for PCB (Printed Circuit Board) mounting. Follow these guidelines for proper installation:
- Pin Orientation: Refer to the schematic diagram (Figure 3) for correct primary (PRI) and secondary (SEC) pin assignments. Primary pins are typically 1-5, and secondary pins are 7-9 (single output) or 7-8 and 9-10 (double output).
- PCB Layout: Ensure your PCB design accommodates the transformer's dimensions (32.5mm x 27.5mm x 23.9mm) and pin spacing (5mm, 10mm, 5mm as shown in Figure 3).
- Soldering: Use appropriate soldering techniques to securely attach the transformer pins to the PCB. Ensure good solder joints for reliable electrical connection.
- Ventilation: Although designed for low temperature rise, ensure adequate ventilation around the transformer on the PCB to prevent heat buildup, especially in enclosed spaces.
- Voltage Selection: Select the appropriate primary voltage (110V, 220V, 230V, or 380V) and secondary output voltage (6V to 24V, single or double) based on your application requirements.
5. Operating Instructions
Once installed, the PE3013-M transformer operates by converting AC input voltage to the desired AC output voltage. No specific user interaction is required during normal operation.
- Input Voltage: Ensure the applied primary voltage matches the transformer's rated primary voltage (110V, 220V, 230V, or 380V) within the ±10% tolerance.
- Output Load: Do not exceed the specified full-load current for the selected secondary voltage to prevent overheating and potential damage.
- Environmental Conditions: Operate the transformer within the specified temperature range of -30°C to +70°C.
6. Maintenance
The PE3013-M transformer is designed for long-term, maintenance-free operation due to its robust encapsulated design. However, periodic checks are recommended:
- Visual Inspection: Periodically inspect the transformer and surrounding PCB area for any signs of physical damage, discoloration, or loose connections.
- Cleaning: If necessary, gently clean the exterior of the transformer with a dry, soft cloth. Avoid using liquids or abrasive cleaners.
- Environmental Control: Ensure the operating environment remains within the specified temperature and humidity limits to maximize the transformer's lifespan.
7. Troubleshooting
If you encounter issues with your PE3013-M transformer, consider the following common troubleshooting steps:
- No Output Voltage:
- Check the input power supply to ensure it is active and within the specified voltage range.
- Verify all connections (primary and secondary) are secure and correctly soldered.
- Inspect for any visible damage to the transformer or PCB traces.
- Incorrect Output Voltage:
- Confirm the input voltage is stable and matches the transformer's rating.
- Ensure the load connected to the secondary side is not exceeding the maximum rated current. Excessive load can cause voltage drop.
- Overheating:
- Check if the ambient temperature is within the operational limits.
- Ensure proper ventilation around the transformer.
- Verify the load is not exceeding the transformer's power rating (1.9VA).
If problems persist, consult a qualified technician or contact YHDC customer support.
8. User Tips
- For applications requiring precise voltage, consider adding a voltage regulator circuit after the transformer's secondary output.
- When designing your PCB, ensure sufficient clearance between the transformer and other heat-sensitive components.
- Always double-check the wiring before applying power to prevent damage to the transformer or connected devices.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official YHDC website or contact your authorized distributor. Keep your purchase receipt as proof of purchase.