Introduction
The Sovol SH02 Filament Dryer is designed to keep your 3D printer filaments dry, ensuring optimal print quality and preventing common issues caused by moisture absorption. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your SH02 Filament Dryer.

The SH02 features a dual-spool capacity, a 150W PTC fast heater, enhanced sealing, one-key settings for various filament types, and smart safety protections.
Safety Precautions
- Please read this manual carefully before use.
- When not in use, always disconnect the power supply.
- When heating, do not touch the shell near the air outlet to prevent burns.
- Do not allow children to operate without adult supervision.
- Use the dryer on a flat, stable surface to prevent it from falling.
- If the power cord is damaged, it must be replaced by the manufacturer or its service agent to avoid hazards.
- Do not place flammable or explosive materials inside the box.
- The equipment circuit contains high-voltage parts. Do not disassemble or repair it yourself. Contact support if any abnormality occurs.
- When the same parameters are set for both chambers simultaneously, there might be a slight difference in temperature display.
Product Description and Parts
Familiarize yourself with the components of your Sovol SH02 Filament Dryer.

- Buckle Lock: Secures the lid.
- Screen: Digital display for settings and real-time monitoring.
- Filament Hole: Openings for filament to pass through.
- Moisture Vent: Allows moisture to escape.
- ON/OFF Switch: Power control.
- Power Cord Interface: Connection for the power cable.
- Filament Outlets: Can be inserted with PTFE tubing to prevent filament from contacting moisture in the air before printing.
- Moisture Outlet: Vent for releasing moisture.
Setup Instructions
1. Initial Setup
- Remove the four sealing plugs from the top cover of the drying box.
- Install the Teflon tubes into the air fittings. If filaments do not feed smoothly during use, ensure the Teflon tube is properly inserted.
- Insert the sharp end of the Teflon tube into the dry box cover about 15mm. Pass the filaments through the Teflon tube from the inside.
2. Power Connection and Filament Loading
- Plug in the power cord of the drying box and press the power switch above the outlet to activate the drying box.
- Open the top cover and place the filament spool(s) to be dried inside the chamber.
- Ensure the filament is placed in the proper orientation to avoid excessive friction between the filament and the filament hole. Incorrect filament delivery can cause stuttering or abnormal noise.
Operating Instructions
1. Control Panel and Screen Parameters
The control panel features several buttons and a digital display for monitoring and setting parameters.

Buttons (from top to bottom):
- Chamber Switching/Copy Key: Short press to switch between Chamber 1, Chamber 2, or dual-chamber simultaneous working mode. Long press (2S) to copy parameters from one chamber to another.
- Setting Selection Key/Auto Mode: Short press to switch parameters. Long press (2S) to enter/leave auto mode.
- Up Arrow: Increases selected value.
- Down Arrow: Decreases selected value.
- Start/End: Starts or ends the drying process.
Screen Parameters:
- Relative Humidity: Current humidity in the chamber.
- Materials: Selected filament type.
- Setting Temperature: Desired drying temperature.
- Current Temperature: Actual temperature in the cavity.
- Time: Countdown of remaining drying time.
- Working Status Icon: Constantly lit during drying.
2. Basic Operation
- After connecting power and pressing ON/OFF, the dryer automatically selects a chamber.
- Press the Start/End button to begin drying with default parameters (e.g., PLA 50°C for 8 hours).
- Use the Start/End button to control the drying process.
- To switch between different parameters within the same chamber, short press the Setting Selection Key. The selected parameter will blink. Adjust with Up/Down arrows. If no operation is performed for 10 seconds, current parameters are saved.
- After modifying parameters in one chamber, use the Chamber Switching Key to switch to another chamber and modify its parameters.
3. Button Expansion Functions
- Copy Parameters: Press Chamber Switching Key to select a chamber, then long press it for 2 seconds to copy its parameters to another chamber.
- Auto Drying Mode: Press Chamber Switching Key to select a chamber, then long press the Setting Selection Key for 2 seconds to enter AUTO mode. The screen will display "AUTO". In AUTO mode, the fan and heating module activate based on humidity thresholds. To exit, select the chamber and long press the Setting Selection Key for 2 seconds.
- Adjusting Parameters: After pressing the Setting Selection Key to select a parameter, use the Up/Down arrows to adjust the value. Wait 10 seconds for the system to confirm and save settings.
4. Filament Drying Parameter Reference
The SH02 has one-key temperature settings for various filament types. You can also manually adjust these.

| Filament | Drying Temperature | Drying Time |
|---|---|---|
| PLA | 50°C | 4-12h |
| PETG | 65°C | 4-8h |
| ABS | 80°C | 8-12h |
| TPU | 70°C | 4-8h |
| PVA | 50°C | 4-8h |
| ASA | 80°C | 8-12h |
| PA | 80°C | ≥12h |
| PP | 55°C | 4-8h |
| PC | 80°C | 8-12h |
| PET | 80°C | 8-12h |
When the drying box is working and the temperature inside the chamber reaches the preset target temperature, the intake and exhaust vents of the automatic dehumidifying module will open.
5. Storage Mode
The SH02 can be used to store dried filaments without power, maintaining their dryness.
- Remove the Teflon tubes and press the rubber plugs tightly into the filament holes.
- Press the Start/End button to end any active drying process. This will automatically close the moisture vents, ensuring a better seal. (Note: Pressing ON/OFF directly will not close the vents automatically, and the unit will not be sealed.)
- Close the lid of the chamber and fasten the buckle lock.
Maintenance
1. Cleaning the Drying Box Interior
Remove any filament residues from the chamber. This can be done with a brush or a small vacuum cleaner.
2. Keep the Workplace Clean
Ensure the area around the drying box is neat and free from dust and debris to prevent them from entering the drying chamber.
3. Desiccant Replacement
The SH02 uses desiccant to help absorb moisture. Replace it as needed.
- Turn off the power.
- Carefully open the desiccant compartment cover.
- Remove the old desiccant and place new desiccant into the tank.
- Ensure the flap of the cover aligns with its notch, then install the cover plate securely.
Troubleshooting
The SH02 features a self-monitoring program. If an abnormality occurs, the PTC heating block and fan will shut down, a buzzer alarm will sound, and an error code will display on the screen.
Exception Codes:
- F1: Fan rotates abnormally.
- F2: Fan Disconnect.
- H1: PTC heating block does not heat properly.
- H2: PTC heating block heats uncontrollably.
- N1: NTC thermistor short circuit.
- N2: NTC thermistor is blocked.
- G1: Temperature and humidity sensor reading abnormality.
- G2: Temperature and humidity sensor communication abnormality.
To clear an alarm: In the settings mode, press the Chamber Switching Key to select the chamber with the error code to eliminate the abnormal alarm status.
Note: Please contact after-sales support if you encounter persistent abnormal alarms.
Specifications
| Feature | Specification |
|---|---|
| Input Voltage | US Regulations: 100-120V 60Hz National/British/European Standard: 200-240V 50Hz |
| Rated Power | 400W |
| Filament Diameter | 1.75mm/2.85mm |
| Maximum Consumable Capacity | Four rolls (≤70mm width each) or One roll (≤150mm width) |
| Display Humidity Range | 0-99% |
| Display Temperature Range | 0-99°C |
| Work Temperature Range | 45°C-85°C |
| Machine Size (L*W*H) | 372mm * 288mm * 263mm |
| Equipment Weight | 3.4KG |
| Environmental Parameters | 5°C-40°C |
| Applicable Filament | PLA, ABS, PETG, TPU, PVA, ASA, PA, PP, PC, PET (and others) |
User Tips
- Fan Noise: Some users note the fan can be loud. Solutions to reduce fan noise may be found online.
- Humidity Sensor: The humidity sensor is generally accurate, showing changes when drying starts and when the chamber is opened.
- Automatic Shut-off: The dryer automatically turns off after the set drying time, which is a convenient feature.
- Coil Size: Be aware that very wide filament spools might not fit, or only one at a time.
- Ventilation: It can be beneficial to ventilate the chamber from time to time during longer drying cycles.
- Drying Effectiveness: Users report significant improvements in print quality after drying filaments with the SH02.
Warranty and Support
For warranty information, technical support, or any issues not covered in this manual, please contact Sovol customer service or visit their official website.
You can find additional resources and join the official user group by scanning the QR codes provided in the original user manual (Page 12 of the PDF manual: Sovol SH02 User Manual PDF).
Manufacturer: Shenzhen Liandianchuang Technology Co., Ltd
Email: info@sovol3d.com