SUMRY SP Series

Contents

SUMRY SP Series Hybrid Solar Inverter

Instruction Manual

Models: SP-2200, SP-3200, SP-4200, SP-7000

1. Introduction and Overview

The SUMRY SP Series Hybrid Solar Inverter is a multi-functional inverter/charger designed to provide uninterruptible power support for various applications. It combines the functionalities of an inverter, an MPPT solar charger, and a battery charger into a compact unit. This inverter is capable of operating off-grid, producing a pure sine wave output, and supports 24VDC or 48VDC battery systems with 220V/230VAC output.

Key features include a wide MPPT operating voltage range (55-450VDC), high maximum charging current (up to 110A depending on model), and compatibility with lithium batteries. It also offers comprehensive protection features and optional Wi-Fi monitoring for enhanced control and convenience.

2. Safety Information

WARNING: Please read and understand all instructions and warnings before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • Ensure all connections are secure and properly insulated to prevent electrical hazards.
  • Do not attempt to disassemble or repair the inverter yourself. Refer all servicing to qualified personnel.
  • Keep the inverter away from flammable materials, moisture, and direct sunlight.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Always disconnect all power sources (PV, battery, and AC) before performing any maintenance or wiring.
  • This inverter is designed for specific voltage and power ratings. Do not exceed these limits.
  • Proper grounding is essential for safe operation.

3. Product Features and Highlights

  • Pure Sine Wave Output: Provides high-quality power suitable for sensitive electronics.
  • Integrated MPPT Solar Charge Controller: Maximizes power harvest from solar panels.
  • Battery Charger Function: Efficiently charges batteries from AC utility or generator.
  • Configurable AC/Solar Input Priority: Allows users to set preferred power source.
  • Auto Restart: Automatically restarts while AC is recovering.
  • Cold Start Function: Enables the inverter to start directly from batteries without AC input.
  • Comprehensive Protection: Includes overload, overheating, high/low voltage, short circuit, overcurrent, anti-reverse, and power failure protection.
  • Communication Ports: Equipped with RS232/RS485 for monitoring and control.
  • Optional Wi-Fi Module: Allows remote monitoring and control via a mobile application (iOS/Android).
  • Wide Compatibility: Works with various household appliances.

4. Product Overview

4.1 Physical Components

The following diagram illustrates the main components and connection points of the SUMRY SP Series Hybrid Solar Inverter:

Diagram of SUMRY SP Series Inverter components

Figure 1: Inverter Physical Components

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons (ESC, UP, DOWN, ENTER)
  6. Power on/off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. RS-232 communication port
  12. Safety (Earth) ground
  13. Circuit breaker

4.2 LCD Display and Function Keys

The LCD display provides real-time information about the inverter's status and allows for configuration. The function keys enable navigation and selection within the menu.

Diagram of LCD display and function keys

Figure 2: LCD Display and Function Keys

LED IndicatorColorMessages
AC / INVGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5. Setup and Installation

Professional installation is highly recommended for safety and optimal performance.

5.1 Mounting the Unit

Consider the following points before selecting where to install the inverter:

Diagram showing mounting clearances for the inverter

Figure 3: Inverter Mounting Guidelines

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

5.2 Wiring Connections

Ensure all wiring is done by a qualified electrician and adheres to local electrical codes.

Rear view of inverter showing connection terminals

Figure 4: Inverter Rear Connections

The video below demonstrates the connection process for the inverter:

Video 1: Product demonstration and connection guide.

5.2.1 Battery Connection

Connect all battery packs as shown in the diagram below. Ensure correct polarity.

Battery connection diagram for 12V and 24V systems

Figure 5: Battery Connection Diagram

  • 1.8KW models support 12VDC systems.
  • 3KW models support 12VDC systems.
  • 3.2KVA/24V models support 24VDC systems.
  • 6.2KW/48V models support 48VDC systems.

5.2.2 System Diagram

The inverter can operate in various configurations, including with or without a battery connected, and can prioritize solar power or grid power.

System diagram showing inverter operation with and without battery

Figure 6: System Operation Diagram

  • Operation with battery connected: Solar Power and AC Power are available. The inverter will manage charging and discharging to provide continuous power.
  • Operation without battery connected: The inverter can power loads directly from PV energy or the grid when solar power and AC power are available. If both are not available, the system will not operate.

6. Operating Instructions

6.1 Powering On/Off

  1. Ensure all connections (battery, PV, AC input/output) are correctly made and secure.
  2. Turn on the circuit breaker (if installed).
  3. Press and hold the Power On/Off switch on the inverter until the LCD display illuminates.
  4. To power off, press and hold the Power On/Off switch until the display turns off, then disconnect all power sources.

6.2 Basic Operation and Monitoring

  • The LCD display will show real-time information such as input voltage, output voltage, battery voltage, charging current, load level, and operational status.
  • Monitor the LED indicators (AC/INV, CHG, FAULT) for quick status checks as described in Section 4.2.
  • Use the UP and DOWN buttons to scroll through different display screens to view various parameters.

6.3 Setting Programs

The inverter allows users to configure various operating parameters through the LCD display. Refer to the detailed user manual for specific program settings.

  1. Press the ENTER button to enter the setting mode.
  2. Use the UP and DOWN buttons to navigate through the available settings.
  3. Press ENTER to select a setting, then use UP/DOWN to change the value.
  4. Press ENTER again to confirm the new value.
  5. Press ESC to exit the setting mode.

6.4 Wi-Fi Monitoring (Optional)

If your inverter is equipped with the optional Wi-Fi module, you can monitor and control it remotely via a smartphone application.

Wi-Fi monitoring feature with QR codes for app download

Figure 7: Wi-Fi Monitoring Setup

  1. Connect the Wi-Fi module to the inverter's communication port.
  2. Download the SmartESS app for iOS or Android by scanning the QR codes provided in the image or searching your app store.
  3. Follow the in-app instructions to connect your inverter to the Wi-Fi network and register it for remote monitoring.

7. Specifications

The following table provides detailed specifications for different models within the SUMRY SP Series:

Table of product parameters for SUMRY SP Series inverters

Figure 8: Product Parameters Table

ModelSP-2200SP-3200SP-4200SP-7000
Rated Power2200VA/1800W3200VA/3000W4200VA/3800W7000VA/6200W
MAX. PV Array Power2000W3000W6000W6000W
Surge Power4400VA6400VA8000VA14000VA
MAX. Charging Current80A80A110A110A
Battery Voltage12V24V24V48V
MPPT Range@Operating Voltage55-450VDC
MAX. Efficiency98%
Dimension D*W*H (mm)405*286*98mm405*286*98mm423*290*100mm423*310*106mm
Net Weight (kgs)4.5kg5.0kg7.0kg8.0kg

Important Notes:

  • Ensure the power rating of the inverter is higher than the appliance you intend to power.
  • It is recommended to purchase a model with at least 10% to 20% more capacity than your maximum expected load.
  • If you plan to run multiple appliances simultaneously, refer to their total combined wattage.
  • For running inductive loads (e.g., motors, refrigerators) for extended periods, a pure sine wave inverter like this one is essential.

8. Troubleshooting

If you encounter issues with your inverter, follow these general troubleshooting steps:

  • Check all connections: Ensure battery, PV, and AC connections are tight and correctly polarized.
  • Verify power sources: Confirm that solar panels are receiving adequate sunlight and that the AC utility/generator is providing power.
  • Examine LCD display: Look for any error codes or fault indicators. Refer to the detailed user manual for a list of error codes and their meanings.
  • Check LED indicators: Observe the FAULT LED. If it's solid red or flashing, a fault or warning condition exists.
  • Reduce load: If an overload fault occurs, disconnect some appliances to reduce the load on the inverter.
  • Battery voltage: Ensure your battery voltage is within the acceptable operating range for your inverter model. Low battery voltage can trigger shutdowns.
  • Ventilation: Confirm that the inverter's ventilation openings are not blocked and that it's operating within the recommended ambient temperature range.

If the problem persists after performing these checks, contact customer support or a qualified technician.

9. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your inverter:

  • Cleaning: Periodically clean the exterior of the inverter and ensure that the ventilation openings are free from dust and debris. Use a soft, dry cloth. Do not use liquid cleaners.
  • Connection Checks: Annually inspect all electrical connections (battery, PV, AC) for tightness and signs of corrosion. Tighten any loose connections.
  • Environmental Conditions: Ensure the inverter remains in a clean, dry, and well-ventilated area, away from extreme temperatures and humidity.
  • Battery Maintenance: Follow the manufacturer's recommendations for your specific battery type (e.g., lead-acid, lithium) regarding charging, discharging, and periodic checks.

10. User Tips

  • Battery-less Operation: The SUMRY SP Series inverter can indeed operate without a battery connected, drawing power directly from solar panels or the utility grid. This is useful for systems where battery storage is not required or desired.
  • Sizing for Appliances: Always ensure the inverter's rated power is sufficient for your appliances. If running multiple devices, sum their wattages and add a buffer (10-20% extra capacity) to account for startup surges, especially for inductive loads like refrigerators or pumps.
  • Remote Monitoring: Utilize the optional Wi-Fi module and SmartESS app for convenient remote monitoring of your system's performance, battery status, and energy production from your smartphone.

11. Warranty and Support

The SUMRY SP Series Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.

For technical assistance, troubleshooting beyond the scope of this manual, or warranty inquiries, please contact the SUMRY Official Store or your authorized dealer. Provide your product model number and a detailed description of the issue to expedite support.

© 2024 SUMRY. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.