BTMETER HP-1580-APP

Contents

User Manual: HOLDPEAK HP-1580-APP Laser Infrared Thermometer

Model: HP-1580-APP | Brand: BTMETER

1. Introduction

The HOLDPEAK HP-1580-APP is a non-contact infrared thermometer designed for safe and accurate temperature measurement across a wide range. It features adjustable emissivity, dual laser targeting, and Bluetooth connectivity for mobile app integration, allowing for advanced data logging and alarm settings. This manual provides essential information for the proper use and maintenance of your device.

HOLDPEAK HP-1580-APP Infrared Thermometer with carrying case and smartphone showing app interface

Figure 1: HOLDPEAK HP-1580-APP Infrared Thermometer with accessories.

2. Safety Information

WARNING: LASER RADIATION. DO NOT STARE INTO BEAM.

  • This device uses a Class 2 laser product with an output wavelength of 630-670nm.
  • Avoid direct eye exposure to the laser beam.
  • Do not point the laser at people or animals.
  • Do not use the device near explosive gases, vapor, or dust.
  • Keep the device away from children.

3. Package Contents

Please check the package for the following items:

  • 1 x HOLDPEAK HP-1580-APP Infrared Thermometer
  • 1 x User Manual
  • 1 x Storage Bag
  • 1 x Small Screwdriver
  • 1 x 9V Battery (pre-installed or included separately)

4. Setup

4.1. Battery Installation

  1. Locate the battery compartment cover on the handle.
  2. Use the provided small screwdriver to open the battery cover.
  3. Connect a 9V battery to the battery clip, ensuring correct polarity.
  4. Insert the battery into the compartment and close the cover securely with the screwdriver.

Video 1: Product overview, battery installation, and button functions.

This video demonstrates the unboxing, battery installation, and basic button functionalities of the HP-1580-APP thermometer.

5. Operating Instructions

5.1. Basic Operation

  1. Power On: Press the trigger to turn on the device. The LCD display will light up.
  2. Measurement: Aim the thermometer at the target surface. Press and hold the trigger. The temperature reading will appear on the display. Release the trigger to hold the reading.
  3. Distance to Spot Ratio (D:S): The HP-1580-APP has a D:S ratio of 30:1. This means that at a distance of 30 inches, the measurement spot diameter is 1 inch. Ensure you are within the appropriate distance for accurate readings.

5.2. Button Functions

The device features several buttons for various functions:

  • Trigger: Press to power on and initiate measurement. Release to hold the reading.
  • Laser Pointer Button (Laser icon): Press once to turn on the dual laser pointers for targeting. Press again to turn them off.
  • BL/UP Button (Backlight/Up arrow icon): Activates the backlight. In settings mode, it increases values or sets high alarm temperature.
  • T/DN Button (Temperature unit/Down arrow icon): Toggles between Celsius (°C) and Fahrenheit (°F). In settings mode, it decreases values or sets low alarm temperature.
  • MODE Button: Cycles through various display options: MAX (maximum temperature), MIN (minimum temperature), DIF (difference between MAX and MIN), AVG (average temperature), HAL (high alarm limit), LAL (low alarm limit), and REC (record mode).
  • E Button: Enters emissivity adjustment mode. Use the BL/UP and T/DN buttons to adjust the emissivity value (0.1 to 1.0).
Infrared thermometer features including backlit display, adjustable emissivity, MAX/MIN/AVG, data hold, dual laser, temperature warning, auto off, flashlight

Figure 2: Key features of the HP-1580-APP thermometer.

5.3. Emissivity Adjustment

Emissivity is crucial for accurate temperature readings. Different materials emit infrared energy differently. Refer to the included emissivity sheet or common values:

  • Asphalt: 0.90 to 0.98
  • Ice: 0.96 to 0.98
  • Wood: 0.90
  • Iron/Copper: 0.78 to 0.82
  • Water: 0.92 to 0.96

To adjust emissivity, press the 'E' button and use the 'BL/UP' and 'T/DN' buttons to set the desired value between 0.1 and 1.0.

Infrared thermometer display showing emissivity setting and a list of common materials with their emissivity values

Figure 3: Emissivity sheet and adjustable emissivity feature.

5.4. High/Low Temperature Alarm

You can set high and low temperature alarms. When the measured temperature exceeds the set limits, the device will alert you.

  1. Press the MODE button until HAL (High Alarm Limit) or LAL (Low Alarm Limit) is displayed.
  2. Use the BL/UP and T/DN buttons to set the desired alarm temperature.
Diagram showing how to set high and low temperature alarms on the thermometer, with visual indicators for low, normal, and high alarm states

Figure 4: High/Low Temperature Alarm setup and indicators.

6. Mobile APP Connection

The HP-1580-APP can connect to your smartphone via Bluetooth for enhanced functionality, including data logging and remote control.

  1. Download the App: Scan the QR code provided in the user manual or search for "AiLink" in the Google Play Store (Android) or Apple App Store (iOS).
  2. Enable Bluetooth: Ensure Bluetooth is enabled on your smartphone.
  3. Pair Device: Open the AiLink app. The app should automatically detect nearby devices. Select the HP-1580-APP from the list to connect.
  4. App Features: Once connected, you can view real-time temperature data, log measurements, set alarms, and adjust settings directly from your phone.
Smartphone screens showing the AiLink app interface for connecting, data logging, and settings, with QR codes for app download

Figure 5: AiLink App interface for connection, data log, and settings.

7. Specifications

FeatureSpecification
Temperature Range-50℃ to 1580℃ (-58℉ to 2876℉)
Accuracy±4% of reading (-50℃ to 0℃); ±2% of reading (≥0℃)
Object Distance Ratio (D:S)30:1
Resolution0.1℃ or 0.1℉
Adjustable Emissivity0.1 to 1.0
Laser Target PointerDual Laser
Response Time<250ms, 95% response
Weight313g
Dimensions212 x 95 x 62mm (8.4 x 3.7 x 2.4 in)
Power1 x 9V Battery
Repeatability1% of reading or 1℃
Data HoldYes
BacklightYes
MAX/MIN/AVG MeasurementYes
High/Low Temperature AlarmYes
Mobile APP ConnectionYes (Bluetooth)
Automatic ShutdownYes

8. User Tips

  • For best accuracy, ensure the target is larger than the measurement spot size. The further away you are, the larger the spot size.
  • Always adjust the emissivity setting to match the material being measured. Incorrect emissivity is a common cause of inaccurate readings.
  • Allow the thermometer to stabilize for at least 30 minutes when moving between environments with significant temperature differences (e.g., from cold outdoors to warm indoors).
  • The mobile app is excellent for monitoring temperature trends over time and setting precise alarms for critical applications.
  • Keep the lens clean for optimal performance.
Infrared thermometer measuring temperature of molten metal in a crucible

Figure 6: Example application of the thermometer for high-temperature measurement.

9. Maintenance

9.1. Cleaning

  • To clean the lens, use a soft cloth or cotton swab with water or medical alcohol.
  • Wipe the device casing with a damp cloth. Do not use abrasive cleaners or solvents.

9.2. Storage

  • Store the device in its carrying bag when not in use to protect it from dust and damage.
  • Remove the battery if the device will not be used for an extended period to prevent leakage.

10. Troubleshooting

ProblemPossible CauseSolution
No display/Device won't turn onLow or dead battery; Incorrect battery installationReplace the 9V battery; Ensure battery is installed with correct polarity.
Inaccurate readingsIncorrect emissivity setting; Distance too far from target; Lens is dirty; Device not stabilized to ambient temperature.Adjust emissivity for the target material; Move closer to the target (within D:S ratio); Clean the lens; Allow device to acclimate to ambient temperature.
"HI" or "LOW" displayedTemperature exceeds measurement range; Temperature exceeds set alarm limits.Ensure target temperature is within the device's range (-50℃ to 1580℃); Check and adjust high/low alarm settings if applicable.
Cannot connect to mobile appBluetooth is off on phone/device; App not installed or updated; Device too far from phone.Ensure Bluetooth is active on both devices; Download/update AiLink app; Keep phone close to the thermometer during pairing.

11. Warranty and Support

This HOLDPEAK HP-1580-APP Infrared Thermometer comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance, or warranty claims, please contact the seller or manufacturer directly. Please retain your proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.