1. Introduction

The ANENG GN702 is a compact and intelligent digital LCR tweezer bridge designed for precise testing of electronic components. It features an OLED display for clear readings and is powered by a long-lasting lithium polymer battery. This smart tweezer automatically identifies resistors, capacitors, and inductors, offering a wide measurement range and high accuracy. Its portable design and flexible, detachable gold-plated measuring tips make it ideal for various SMD and other LCR parameter measurements in electronic maintenance, circuit board repair, and DIY projects.

ANENG GN702 Smart Tweezer highlighting key features like lithium battery charging, automatic identification, multiple measurable parameters, set calibration, and data retention.
Figure 1: ANENG GN702 Digital LCR Smart Tweezer with key features.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and undamaged:

  • 1 x Packing Box
  • 1 x User Manual (this document)
  • 1 x Storage Bag
  • 1 x Tweezers Bridge (Main Unit)
  • 1 x Charging Cable (Type-C)
Contents of the ANENG GN702 package including the device, manual, charging cable, storage bag, and packing box.
Figure 2: Included accessories with the ANENG GN702.

3. Product Overview

Familiarize yourself with the components and controls of your ANENG GN702 Smart Tweezer:

Diagram of the ANENG GN702 Smart Tweezer with numbered labels for its parts: 1. Type-C interface, 2. Charging indicator, 3. OLED display, 4. Power/Function/Settings button, 5. Frequency/Menu Navigation button, 6. HOLD/Voltage/Menu Navigation button, 7. Forceps head, 8. Measuring arm.
Figure 3: ANENG GN702 labeled parts and dimensions.
  1. Type-C interface: For charging the device.
  2. Charging indicator: Shows charging status (red for charging, blue for full).
  3. OLED display: High-contrast screen for displaying measurement results and settings.
  4. Button 1 (Top): Short press to turn on, long press to turn off. In measurement interface, short press to switch function/settings interface. Short press function to exit.
  5. Button 2 (Middle): In measurement interface, short press to switch frequency. In settings interface, long press to enter/exit, short press to move down menu.
  6. Button 3 (Bottom): In measurement interface, short press HOLD to retain data. Long press to switch to measure voltage. In settings interface, short press to move up menu.
  7. Forceps head: The tip of the tweezers for contacting components.
  8. Measuring arm: The main body of the tweezers that holds the forceps head.

4. Specifications

The following table details the technical specifications and measurement ranges of the ANENG GN702:

FunctionRange100Hz Accuracy1KHz Accuracy10KHz AccuracyMeasuring Range
R Resistance1MΩ - 10MΩ5%±55%±5---Automatic transmission: 10mΩ~10MΩ
Resistance gear: 10mΩ~10MΩ
1KΩ - 1MΩ1%±50.5%±51%±5
1Ω - 1KΩ1%±50.5%±50.5%±5
10mΩ - 1Ω3%±53%±53%±5
C Capacitor1mF - 20mF5%±55%±5---Automatic transmission: 50PF~5mF
Capacitor file: 1PF~20mF
1uF - 1mF2%±52%±52%±5
1nF - 1uF2%±50.5%±50.5%±5
1pF - 1nF---5%±55%±5
L Inductance1H - 60H5%±55%±5---Automatic transmission: 5uH~60H
Inductance file: 1uH~60H
1mH - 1H2%±52%±52%±5
10uH - 1mH2%±50.5%±50.5%±5
1uH - 10uH---5%±55%±5
Frequency100Hz, 1KHz, 10KHzDiodeYes
Voltage0.3V, 0.6VOn/off gearYes
Weight36gData retentionYes
Calibration settings0Ω~10MΩ, OPENAutomatic rangeYes
Language selectionChinese, EnglishLow power promptYes
Screen orientationLeft, right.Battery typeLithium battery 3.7V
Volume settings0%~100%Automatic shutdownClosed, 5 minutes to 120 minutes
Backlight brightness10%~100%Screen displayOLED display

Note: The parameters are for reference only, and the actual measurement of the specific equipment shall prevail.

5. Setup

5.1 Charging the Device

The ANENG GN702 is powered by a built-in lithium polymer battery. Before first use or when the low power prompt appears, charge the device using the provided Type-C charging cable.

  • Connect the Type-C end of the charging cable to the Type-C interface (1) on the device.
  • Connect the USB-A end of the charging cable to a standard USB power adapter (not included).
  • The charging indicator (2) will show a red light while charging.
  • Once fully charged, the indicator light will turn blue.
ANENG GN702 being charged via a Type-C cable, showing red light for charging and blue light for full charge.
Figure 4: Charging the ANENG GN702 with Type-C cable.

5.2 Assembling the Forceps Head

The gold-plated tweezers head is detachable for flexible use in various application scenarios. Ensure it is securely attached before use.

Diagram showing flexible assembly of the gold-plated tweezers head.
Figure 5: Flexible assembly of the tweezers head.

6. Operating Instructions

6.1 Power On/Off

  • To Power On: Short press Button 1.
  • To Power Off: Long press Button 1.

6.2 Automatic Identification Mode

The ANENG GN702 features intelligent automatic identification. Simply turn on the device and touch the component with the forceps head. The device will automatically detect the component type (resistor, capacitor, inductor, or diode) and display its value.

Hand holding ANENG GN702 performing SMD patch test, demonstrating automatic identification of components.
Figure 6: Automatic identification for SMD patch testing.

6.3 Manual Mode and Settings

You can manually switch between different measurement gears and ranges, and access various settings:

  • Switching Functions/Settings: Short press Button 1 in the measurement interface.
  • Switching Frequency: Short press Button 2 in the measurement interface.
  • Entering/Exiting Settings: Long press Button 2.
  • Navigating Menu: Short press Button 3 to move up, short press Button 2 to move down.
  • Data Hold: Short press Button 3 in measurement mode to hold the displayed value.
  • Measure Voltage: Long press Button 3 to switch to voltage measurement mode.
Diagram showing language selection, auto-identification, charge jack, flexible assembly, and automatic shutdown features.
Figure 7: Device settings and features.

6.4 Specific Measurement Types

The ANENG GN702 can measure various electronic components:

  • Resistance (Ω): Automatically identified. Contact the two ends of the resistor with the tweezers.
  • Capacitance (C): Automatically identified. Contact both ends of the capacitor. Remember to discharge capacitors before testing.
  • Inductance (L): Automatically identified. Contact both sides of the inductor.
  • Diode: Press Button 1 to manually switch to the diode gear. Align the diode with the positive and negative electrodes for testing. The device can only measure between 0.1V and 0.6V.
  • Continuity (Buzzer): Press Button 1 to switch to the buzzer gear. Test on and off. A beep indicates continuity.
Illustrations of measuring Resistance, Diode, Capacitor, Buzzer, and Inductance with the ANENG GN702.
Figure 8: Multifunctional measurement capabilities.

6.5 Video Demonstration

Watch this video for a visual guide on how to use the ANENG GN702 for various measurements:

Video 1: Demonstration of ANENG GN702 features and measurement techniques.

7. User Tips

  • Capacitor Discharge: Always remember to discharge capacitors before testing to prevent damage to the device or inaccurate readings.
  • Capacitor Health Check: For capacitors, pay attention to the D-value (Dissipation Factor). A normal capacitance D-value is typically less than 1. If it is greater than 1, the capacitor may be faulty or broken.
  • Transformer Quality: When measuring inductors, especially transformers, a Q-value (Quality Factor) less than 1 often indicates a defective transformer.
  • SMD Component Handling: The fine tips of the tweezers are excellent for handling and testing small Surface Mount Devices (SMD) components directly on circuit boards.
  • Electrical Knowledge: This is a technical product. A certain degree of electrical knowledge is recommended for optimal use and interpretation of results.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in its provided storage bag in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge it regularly, even if not in use for extended periods.
  • Tip Care: The gold-plated tips are delicate. Handle them with care and ensure they are clean for accurate measurements.

9. Troubleshooting

  • Device Not Turning On: Ensure the battery is charged. Connect the charging cable and check if the charging indicator lights up.
  • Inaccurate Readings:
    • Check if the component is properly contacted by the tweezers.
    • Ensure the tips are clean and free from debris.
    • Verify that the correct measurement mode or frequency is selected if not using auto-identification.
    • Perform calibration if necessary (refer to settings menu).
  • No Display/Flickering Display: The OLED display might be affected by extreme temperatures. Ensure the device is used within its operating temperature range. If the issue persists, contact support.
  • Device Not Responding: Try turning the device off and on again. If unresponsive, allow the battery to fully discharge and then recharge.

If you encounter persistent operational problems or do not understand how to use the product, please contact ANENG customer service for assistance.

10. Warranty and Support

ANENG is committed to providing high-quality products. For any quality issues or operational problems not covered in this manual, please contact ANENG customer service. They will provide you with satisfactory solutions in a timely manner.

You can also refer to the official user manual (PDF) for more detailed information: View User Manual (PDF)

ANENG's professional after-sales team contact information and policies regarding quality issues, replacement/refund requests, product not operating properly, product use questions, and artificially damaged products.
Figure 9: ANENG After-Sales Support Information.

11. Frequently Asked Questions (FAQ)

Q: Can this equipment measure the ESR of electric capacitors?
A: Yes, this LCR Smart Tweezer can measure capacitance and its associated parameters (like D-value), which can help in assessing the Equivalent Series Resistance (ESR) of capacitors. A D-value greater than 1 often indicates a faulty capacitor.

Related Documents - GN702

Preview ANENG GN702 LCR Tweezers Bridge Tester User Manual and Specifications
Comprehensive user manual for the ANENG GN702 LCR Tweezers Bridge Tester, detailing specifications, safety precautions, usage instructions, calibration, and maintenance.
Preview ANENG GN703 LCR Bridge Tweezers Tester User Manual
Comprehensive user manual for the ANENG GN703 LCR Bridge Tweezers Tester, detailing its features, specifications, operation, and troubleshooting for accurate resistance, capacitance, inductance, continuity, diode, and frequency measurements.
Preview ANENG AN8205C Digital Multimeter Operator's Instruction Manual
Comprehensive operator's instruction manual for the ANENG AN8205C Digital Multimeter, covering safety information, specifications, operating instructions for various measurements, and maintenance.
Preview ANENG SZ305 Digital Multimeter Operator's Instruction Manual
This manual provides comprehensive safety information, operation instructions, specifications, and maintenance details for the ANENG SZ305 Digital Multimeter, a compact, hand-held, and battery-operated electronic measuring instrument.
Preview ANENG MH15 高精度绝缘电阻测试仪使用说明书
ANENG MH15是一款高精度绝缘电阻测试仪,提供多种测量功能,包括直流/交流电压、电阻、通断、二极管和绝缘电阻。本手册详细介绍了仪器的操作、安全信息和技术规格。
Preview ANENG C08 Automotive Electrical Circuit Tester User Manual
Detailed user manual for the ANENG C08 automotive electrical circuit tester, covering features, functions, and operation for safe and effective circuit diagnostics. Includes instructions for voltage, resistance, diode, and continuity testing.