1. Introduction
The Erilles SK120X is a versatile DC-DC buck-boost converter designed for precise voltage and current regulation. It features a clear VA color LCD display, supports constant voltage (CV), constant current (CC), and constant power (CW) modes, and includes MPPT functionality for solar charging. This module is ideal for various applications requiring adjustable power output with multiple protection mechanisms.
Figure 1: Main display of the SK120X module.
Video 1: Product demonstration and feature overview of the SK120X.
2. Safety Information
- Always check the product before use to ensure it is in proper working condition.
- Use the product properly and according to the instructions provided.
- Keep the device away from fire, excessive heat, and sharp objects.
- Keep small parts away from children under 3 years of age.
- Do not disassemble the product unless explicitly instructed for maintenance or repair by qualified personnel.
- ATTENTION: Not suitable for children under three years.
- When connecting to an external temperature probe for MPPT solar charging, ensure correct polarity. Reversing positive and negative terminals of the battery will damage the device.
- Battery charging requires certain professional knowledge. Non-professionals are not allowed to charge directly to prevent fire and explosion.
3. Specifications
3.1. Product Parameters
| Parameter | Value |
|---|---|
| Product Name | CNC DC Step-up and Step-down Power Supply |
| Input Voltage | 6.0V ~ 36.00V |
| Output Voltage | 0V ~ 36.00V |
| Output Current | 0A ~ 6.000A |
| Output Power | 120W (up to 150W with optimal cooling) |
| Voltage Accuracy | ±0.5% + 1 word |
| Current Accuracy | ±0.5% + 3 words |
| Voltage Resolution | 0.01V |
| Current Resolution | 0.001A |
| Storage Data Groups | 10 groups (Cd0-Cd9) |
| Number of Buttons | 5 |
| Screen Size | VA Color LCD, >1.8 inches (38x29mm visual range) |
| Buzzer | Yes |
| Conversion Efficiency | Approx. 88% |
| Soft Start | Yes |
| MPPT Function | Supports MPPT solar charging |
| Output Ripple (Typical) | vpp-150mv |
| Product Size | 86mm x 50mm x 45mm |
| Certification | CE |
3.2. Protection Mechanisms
- Input Anti-Reverse Connection: Yes
- Output Anti-Backflow: Yes
- Input Undervoltage Protection (LVP): 5.5-36V adjustable, default 5.5V
- Output Overvoltage Protection (OVP): 0-38V adjustable, default 38V
- Output Overcurrent Protection (OCP): 0-6.2A adjustable, default 6.2A
- Output Over-Power Protection (OPP): 0-150W adjustable, default 125W
- Over-Temperature Protection (OTP): 0-110℃ adjustable, default 95℃
- Timeout Protection (OHP): 1 minute - 99 hours 59 minutes, default OFF
- Over Capacity Protection (OAP): 0-9999Ah adjustable, default OFF
- Over Energy Protection (OPH): 0-4200KWh adjustable, default OFF
Figure 2: Overview of the protection mechanisms displayed on the module.
4. Product Overview
The SK120X module features a compact design with an integrated injection-molded, flame-retardant shell and a double-layer buckle for secure circuit board fixation. It includes silicone buttons with indicator lights for comfortable and intuitive operation.
Figure 3: Display board design and physical features.
4.1. Components and Interfaces
- Input/Output Terminals: Clearly labeled IN+, IN-, OUT+, OUT- for power connections.
- NTC 3905B External Temperature Sensor Interface: For connecting an external temperature probe.
- Dual Inductance Design: Utilizes high-power, high-temperature resistant FeSiAl magnetic ring inductors.
- High-Quality Solid-State Capacitor: Ensures stable performance.
- Intelligent Temperature-Controlled Fan: With large-area ventilation heat sinks for efficient cooling.
- Output 2-stage Filtering: RC filtering for clean output.
Figure 4: Internal components and connection points.
4.2. Dimensions
Figure 5: Module dimensions and recommended panel cutout.
5. Setup
5.1. Basic Wiring
Connect your DC input power source to the IN+ and IN- terminals. Connect your load or device to the OUT+ and OUT- terminals. Ensure correct polarity for all connections.
5.2. MPPT Solar Charging Setup
For MPPT solar charging, connect your solar panel to the input terminals (IN+, IN-) and the battery to be charged to the output terminals (OUT+, OUT-). An external NTC temperature probe can be connected to the dedicated interface to support over-temperature protection for the battery. The battery icon will be displayed on the screen once connected.
Attention: This product does not have output reverse connection protection. Reversing the positive and negative terminals of the battery will damage the device. Battery charging requires certain professional knowledge. Non-professionals are not allowed to charge directly to prevent fire and explosion.
Figure 6: MPPT solar charging connection diagram.
5.3. Remote Control Pairing (for models with 433MHz kit)
The initial power-on requires pairing. During this process, the red light of the 433MHz receiver board will flash frequently. Press and hold any button on the remote control to initiate pairing. The red light will go out upon successful pairing.
Figure 7: Remote control receiver indicator description.
6. Operating Instructions
6.1. Button Functions Overview
Figure 8: Main module button functions.
- V-SET Button: Short Press to set voltage (CV). Long Press to enter or exit the data group UI.
- SW Button: Short Press to switch between input/output voltage or shift. Long Press to enter or exit the system settings UI.
- I-SET Button: Short Press to set current (CC). Long Press to enter or exit the data group settings UI.
- Encoder Button: Short Press to switch between output power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C) display in rotation. Long Press to turn on/off the key lock.
- Power Button (ON/OFF): Short Press to turn on/off the power output. Long Press to reset the capacity (Ah), energy (Wh), and time (h) UI.
6.2. Setting Voltage and Current
- On the main UI, short press the V-SET button to set the voltage. The LCD will display "SET" in the lower row, and "CV" will flash to indicate that the voltage setting position is selected and blinking.
- Then, short press the SW button or rotate the encoder to switch the voltage setting position. Adjust the value by rotating the encoder.
- After setting is complete, short press the V-SET button to exit and save.
- To set the current, short press the I-SET button, and the setting steps are the same as for voltage.
Figure 9: Instructions for setting voltage and current.
6.3. Quick Setting of Voltage or Current (FET Parameter)
In the system parameter settings UI, set the parameter FET to CV or CC. Rotate the encoder on the main UI to enter the voltage or current setting UI. Rotate the encoder to quickly set the voltage or current.
6.4. UI Function Details
When the power supply is ON, the display shows constant voltage (CV), output voltage, output current, power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C). Short pressing the Encoder button toggles between these displays.
When connected to an external temperature probe (10K 3950B NTC), it will automatically display the probe's temperature.
When the power is OFF, the set voltage and current are displayed, along with the external probe temperature.
Figure 10: Product UI function details.
6.5. Key Lock Function
On the main UI, press and hold the encoder button for 2 seconds to lock the set voltage and current to prevent accidental modification. A lock symbol will appear on the display. To unlock, press and hold the encoder button for another 2 seconds.
6.6. Data Group Function
The product supports 10 data groups (Cd0 to Cd9). Press and hold the V-SET button on the main UI to access the data group UI. You can press V-SET/I-SET briefly to switch between constant voltage (CV) and constant current (CC) settings within a data group. After confirming the data group, press and hold the V-SET/SW button or press the encoder button briefly to select the desired data group.
Figure 11: Data Group Parameter Settings UI.
Figure 12: Setting parameters within data groups.
6.7. System Parameter Settings
Press and hold the SW button on the main interface to enter the settings menu. Press V-SET briefly to select the next parameter, and press I-SET briefly to select the previous parameter. After completing the settings, press and hold the SW/encoder button to exit the settings.
Figure 13: System Parameter Settings menu.
6.8. Introduction to CV/CC/CW Functions
When the constant power function is not turned on, the power supply operates in constant voltage (CV) and constant current (CC) modes, automatically switching based on the load:
- Constant Voltage (CV): When the load current is less than the set constant current value, the power supply is in constant voltage mode. The output voltage is the set CV value, and the current is adaptive.
- Constant Current (CC): When the load current exceeds the set constant current value, the power supply automatically enters constant current mode. The output current is the set CC value, and the voltage is adaptive.
After the constant power function is turned on, the constant voltage value defaults to the maximum value, and the constant voltage value CV serves as the initial voltage (set to a reasonable value based on actual conditions). The power supply calculates the equivalent resistance R of the load using Ohm's law R=U/I. The corresponding voltage can be calculated based on the set constant power value using the power formula P=U²/R. At this point, the constant power point algorithm automatically follows, and the constant power is achieved.
To enable/disable Constant Power (CP) function:
- Press and hold SW on the main UI to enter system settings.
- Press I-SET/V-SET briefly to switch to the "CP" constant power switch option.
- Press ON to enable constant power and OFF to disable it.
- After enabling constant power, press I-SET briefly on the main interface to modify the value of constant power.
Figure 14: CV, CC, and CW function displays.
7. Remote Control (Optional)
The SK120X supports an optional 433MHz wireless remote controller and receiver module, as well as an IR remote control kit. These allow for convenient remote operation.
Figure 15: 433MHz Wireless Remote Controller and Receiver Module.
7.1. Remote Control Key Functions
Figure 16: Remote control key and function description.
7.2. Infrared Receiving Probe
The infrared receiving probe can be used in an upright position without affecting the signal. It allows the module to be connected to an infrared receiver module for remote control.
Figure 17: Infrared receiving probe.
8. Software Control
The SK120X supports serial communication and can be controlled via complementary commercial software. This software offers:
- Unlimited Device Connectivity: Supports multi-serial port communication, allowing up to 247 devices to be connected to a single serial port.
- Batch Control: Enables batch control of all devices under a specific account, including voltage, current, switches, and other parameters.
- Administrative Accounts: Management accounts can be added for more secure and controlled access to voltage and current settings.
The software is constantly being upgraded, and the interface is maintained as the latest version.
Figure 18: Commercial software interface for multi-device control.
8.1. Firmware Upgrade
The product supports firmware upgrades to obtain new functions. Currently, it supports firmware upgrade through the WiFi module. In the future, it will also be able to upgrade through multi-serial port host computer software.
Note: Do not power off during the product upgrade process. If the product upgrade fails, you can press and hold the power button to power on the product and force it into the upgrade mode.
Figure 19: Firmware upgrade interface.
9. Maintenance
- Keep the device clean and free from dust and moisture.
- Avoid exposing the module to extreme temperatures or direct sunlight for prolonged periods.
- Regularly check connections for tightness and signs of wear.
- If the fan becomes noisy or stops working, inspect for obstructions or contact support.
10. Troubleshooting
- No Power/Display: Check input voltage connections and ensure the input voltage is within the specified range (6.0V-36.00V).
- Output Not Stable: Verify load connections. Ensure the output power does not exceed 120W (or 150W with optimal cooling). Check for proper cooling.
- Protection Triggered (LVP, OVP, OCP, OPP, OTP): The display will indicate which protection mechanism has been activated. Identify and resolve the underlying issue (e.g., input voltage too low, output voltage too high, excessive current/power, overheating).
- Remote Control Not Responding: Ensure the remote control is paired correctly (refer to Section 5.3). Check battery in remote control. Ensure line of sight for IR remote.
- Firmware Upgrade Failure: Do not power off the device. Force it into upgrade mode by pressing and holding the power button during power-on, then attempt the upgrade again.
11. User Tips
- For precise voltage and current settings, utilize the encoder knob for fine adjustments after selecting the digit with the SW button.
- Save frequently used voltage/current settings into the 10 data groups (Cd0-Cd9) for quick recall.
- When using the MPPT solar charging feature, always monitor battery temperature, especially if an external probe is not used, to prevent overheating.
- Consider using the optional WiFi module for remote monitoring and control, which can be particularly useful in inaccessible setups.
12. Warranty and Support
This product is quality guaranteed. For any after-sales service or technical support, please contact the seller or manufacturer. Please refer to the official user manual PDF for additional detailed information and diagrams.
A user manual in PDF format is available for download: View User Manual (PDF)