1. Important Safety Instructions
Please save these instructions.
This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information.
| Icon | Description |
|---|---|
| WARNING | Indicates a potentially dangerous condition. Use extreme caution when performing this task. |
| CAUTION | Indicates a critical procedure for safe and proper operation of the controller. |
| NOTE | Indicates a procedure or function that is important to the safe and proper operation of the controller. |
1.1 General Safety Information
- Read all of the instructions and cautions in the manual before beginning the installation.
- There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
- Do NOT allow water to enter the controller.
- Make sure all connections going into and from the controller are tight.
1.2 Charge Controller Safety
- NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.
- Ensure input voltage does not exceed 160 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.
1.3 Battery Safety
- Use only sealed lead-acid, flooded, gel or lithium batteries which must be deep cycle.
- Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
- Be careful when working with large lead acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid.
- Carefully read battery manuals before operation.
- Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Recycle battery when it is replaced.
- Over-charging and excessive gas precipitation may damage the battery plates and activate material shedding on them. Too high of an equalizing charge or too long of one may cause damage. Please carefully review the specific requirements of the battery used in the system.
- Equalization is carried out only for non-sealed / vented/ flooded / wet cell lead acid batteries.
- Do NOT equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by battery manufacturer.
WARNING
Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to charge controller until the battery is connected.
Do NOT connect any inverters or battery charger into the load terminal of the charge controller.
Once equalization is active in the battery charging, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries when in equalization charging stage.
2. Product Overview
The PowMr 60A MPPT Solar Charge Controller is an advanced maximum power point tracking (MPPT) technology-based device designed for solar systems. It boasts a charge controller conversion efficiency of up to 97%.
2.1 Key Features
- MPPT 60A solar charge controller.
- 100% MPPT technology.
- Built-in DSP controller with high performance.
- Automatic switch for 12V/24V/36V/48V battery bank.
- 3-stage charging optimizes battery performance.
- Overcharge protection, Input PV polarity reverse protection, Output limited current protection, over-temperature protection.
- Troubleshooting promotion function.
- Suitable for battery types such as sealed lead acid, vented gel, and lithium battery, etc.
- Easy to be mounted.
Note:
The output terminal is for lamp only (12V system less than 60W, 24V/36V/48V system less than 100W), and it will be burnt if connecting to other loads. The output for battery has no polarity reverse protection.
2.2 Product Advantages

Image Description: A comparison highlighting the PowMr MPPT Controller's superior features including 99% efficiency, fast charging, support for 12V/24V/36V/48V batteries, and higher current/PV voltage limits (Max. PV 160VDC) compared to other controllers with lower efficiency and limited battery/voltage support.

Image Description: Diagram illustrating the 3-stage charging process (Equalize Charge, Boost Charge, Float Charge) for rapid, efficient, and safe charging of sealed lead-acid, vented Gel, and Lithium batteries, with peak conversion efficiency of 98% and high tracking efficiency up to 99%.

Image Description: Visual representation of the multi-function protection features including load short circuit, battery over discharge, battery reverse polarity, PV short circuit, PV over current alarm, battery overcharge, controller overheating, and load overload protection. Also shows internal components like Capacitance and Copper Coil Transformer.

Image Description: A detailed internal view of the PowMr MPPT Solar Charge Controller, highlighting the copper coil transformers and capacitors, indicating robust construction.
3. Installation and Setup
3.1 Dimensions

Image Description: A technical drawing showing the dimensions of the MPPT Solar Charge Controller: 21.4cm length, 11.5cm width, and 5cm height.
Notes: Please use only the provided screws. Using other screws may damage the internal PCB. Apply proper torque to push the screws into the casing to avoid damaging the internal PCB.
3.2 Wiring Instructions
Video Description: This video demonstrates the unboxing of the HHJ-60A MPPT Solar Charge Controller and provides a basic visual guide for connecting the battery to the controller.
- 1st step: Connect the batteries
Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (with the battery symbol). If the system is 12V, ensure your battery voltage is more than 12V for the controller to boot up. - 2nd step: Connect the solar panel
Ensure that the PV modules are protected from incident light and that the solar panel doesn't exceed the maximum permissible input current. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (with the PV modules symbol). - 3rd step: Connect loads
Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (with the lamp symbol). To avoid any voltage on the wires, connect the wire to the load before connecting to the controller. - 4th step: Final work
Tighten all cables connected to the controller and remove all debris around the controller (leaving a space of approx. 5.91 inches for ventilation).
3.3 Air Circuit Breaker Installation
We strongly recommend connecting a fuse directly to the battery to protect against any short circuit at the battery wiring. Solar PV modules create current whenever light strikes them. The current created varies with light intensity, but even at low light levels, full voltage is given by the modules. Therefore, protect the solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure the wire diameter is in accordance with the expected currents of the solar charge controller. Connections must always be made in the sequence described below.
| Models | Copper wires | Air circuit breakers |
|---|---|---|
| MPPT-60A | 6mm²x2PCS | 100A |
3.4 Wiring Diagram

Image Description: A comprehensive wiring diagram showing connections for PV Solar Panels, the MPPT Solar Charge Controller, Battery, DC Load, AC Load, and Inverter. It also indicates support for parallel connection of two 60A controllers to achieve 120A.
Reminder: It’s better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it’s the same way to connect wires.
- Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
- Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and controller.
- Turn on the air circuit breaker between controller and batteries.
- Turn on the air circuit breaker between controller and PV modules.
- The controller goes into the self-test mode. Its LCD displays the parameters if all is correct. And RUN lamp (under the fan inside of casing) will flash every one second. If the controller is not responsive, please read the full manual again for reinstalling or contact us for help.
4. Operation
4.1 LCD Display

Image Description: The LCD display interface of the controller, showing main interface parameters like PV voltage/output power, battery voltage/charging current, working mode/temperature, and fault code. It also illustrates the sub-interface for load timer, floating voltage, absorption voltage, battery type, and under-voltage disconnection voltage.
The LCD display provides real-time information about the system's status. The main interface shows PV voltage, output power, battery voltage, charging current, working mode, temperature, and any fault codes. The sub-interface allows access to settings for load timer, floating voltage, absorption voltage, battery type, and under-voltage disconnection voltage.
| Item | Description |
|---|---|
| 1 | PV voltage / Output power |
| 2 | Battery voltage / Charging current |
| 3 | Working mode / Temperature |
| 4 | Fault code |
4.2 Working Modes
| Mode | Description |
|---|---|
| 3.0 | Night mode, no charging |
| 4.0 | MPPT mode |
| 7.0 | Absorption mode |
| 8.0 | Floating mode |
4.3 Manual Settings
Reminder: The controller will work fine under default settings except for lithium batteries.
CAUTION! All steps must be carried out when the PV modules are disconnected from the controller.
- Step 1: D00 (Load Working Time)
Press the PRG button, then the LCD displays D00. This is for setting the load working time (Default is 24-hour). Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm. The output voltage is the same as the battery. The load is only for small DC loads less than 5A current. If no load, leave it. - Step 2: D01 (Floating Charging Voltage)
Press the UP button, the LCD shows 13.8 (default value). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. - Step 3: D02 (Absorption Charging Voltage)
Continue to press the UP button, the LCD shows 14.5. This is the highest absorption charging voltage for the battery. Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. - Step 4: D03 (Battery Discharge Protection)
Continue to press the UP button, the LCD shows 10.0. This is the protection value for battery discharge. Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. This means it's protected when a 12V battery is less than 10.0V, and there is no output power from OU+ and OU-. - Step 5: D04 (Battery Type)
Continue to press the UP button, the LCD shows 00.00, which is the default for acid batteries. If it's for a lithium battery, press ENT until numbers flash, then use UP/DOWN to choose 01. Long-press ENT to confirm. Step 2 (D01) is not useful when you choose 01 for lithium battery. The voltage set in step 3 (D02) will be the highest charging voltage for the lithium battery. - Step 6: D05 (Battery Voltage Calibration)
Continue to press the UP button, the LCD shows C+ "the currently detected battery voltage". This setting item is used to calibrate the battery voltage by adjusting the value, ensuring that the battery voltage detected by the controller matches the actual battery voltage.
CAUTION! This value is for one 12V battery. If there are many batteries in series, the controller will multiply them in proportion automatically, and the LCD only displays the voltage of one battery (e.g., for a 4x12V battery system, if you set 14.1V, the charge voltage will be 4x14.1V automatically, but the LCD only displays 14.1V).
Press ESC to exit the setting menu.
Reminder: When you set up all steps, please disconnect the battery. Reconnect the controller to see if all settings are successful. When all settings are OK, then connect PV modules to the controller.
5. Maintenance
- The controller contains no serviceable parts. Do NOT attempt to disassemble or repair the unit.
- Prevent water ingress into the controller.
- Regularly check and ensure all electrical connections are tight to prevent sparks and ensure optimal performance.
6. Troubleshooting and Protections
6.1 Troubleshooting Guide
| Code | Description | How to solve |
|---|---|---|
| 18 | Input PV voltage is low | Increase the PV voltage |
| 60 | Over-temperature protection | Fan will work and temperature reduction automatically |
| 63 | Battery voltage is high | Battery high voltage protection and wait for recovery |
| 65 | Battery voltage is low | Battery over-discharge and wait for recovery |
| 71 | Input PV voltage is high | Decrease the PV voltage |
| 73 | Over-charging current | Decrease the PV power |
6.2 Protections
- PV Over Current: The controller will limit charging power to its rated charge power. An over-sized PV array will not operate at maximum power point.
- PV Short Circuit: When a PV short circuit occurs, the controller will stop charging. Remove the short to resume normal operation.
- PV Reverse Polarity: Full protection against PV reverse polarity is provided, causing no damage to the controller. Correct the connection to start normal operation.
- Battery Over Voltage: If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system), 31.0V (for 24V system), 46.5V (for 36V system), or 62.0V (for 48V system), the controller will stop charging to protect the battery from overcharging damage. (Note: stopping charge means charging current is very low).
- Battery Over Discharge: When battery voltage drops to the set low voltage disconnect point, the controller will stop discharging to protect the battery from over-discharging damage.
- Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
- Load Short Circuit Protection: Once a load short circuit happens, the Load Short Circuit Protection will start automatically.
- Over Temperature Protection: The controller has built-in over-temperature protection.
7. Specifications
| Category | Parameter | Value (HHJ-60A) |
|---|---|---|
| Charging Mode | Type | 3-stage: constant current (MPPT), 4-stage: constant voltage, Floating |
| Max Efficiency | ≥98.1% | |
| PV Utilization | ≥99% | |
| Max. PV Input Power | 12V System | 720W |
| 24V System | 1440W | |
| 36V System | 2100W | |
| 48V System | 2800W | |
| Input Specification DC | 12V System | 20V~80V |
| 24V System | 37V~105V | |
| 36V System | 50V~160V | |
| 48V System | 72V~160V | |
| Battery Voltage Automatic Recognition | 12V System | DC9V~DC15V |
| 24V System | DC18V~DC29V | |
| 36V System | DC30V~DC39V | |
| 48V System | DC40V~DC60V | |
| Overcharging Protection Voltage | 60V | |
| Limited Current Protection | 61A | |
| Temperature | Temperature Protection | 75°C / 167°F |
| Fan-on Temperature | >45°C / 104°F | |
| Fan-off Temperature | <40°C / 95°F | |
| Physical Properties | Size (mm)/(in) | 214x115x50mm / 8.43x4.53x1.97in |
| Net Weight (Kg)/(lb) | 1.1 / 2.43 | |
| Gross Weight (Kg)/(lb) | 1.2 / 2.65 | |
| Enclosure | IP21 | |
| Environmental Conditions | Operating Temperature | -20°C ~ +55°C |
| Storage Temperature | -40°C ~ +75°C | |
| Electromagnetic Compatibility | Accord to EN61000, EN55022, EN55024 | |
8. Warranty and Support
8.1 Warranty Regulations
Any damaged unit caused by the user's failure to install, disassemble, or incorrect use of this product may void the warranty.
- Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (with authorization from the company).
- Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.
Notes: Disassembled privately, no warranty.
8.2 Contact and Support
If you have any questions or require support, please contact us first.
- Email: support@powmr.com
- Web: www.powmr.com
For additional information, you can refer to the official user manual PDF: PowMr MPPT Solar Charge Controller User Manual (PDF)
9. User Tips
- Corrosion Prevention: To prevent corrosion of internal components due to condensation, consider applying a protective coating or paint to the circuit board, especially if the unit is exposed to environments with significant temperature fluctuations.
- Optimizing Charging: The controller uses a 3-stage charging process (constant current, constant voltage, floating charge, bulk charge) for optimal battery performance. Ensure your battery type is correctly configured in the settings for efficient charging.
10. Content Included
- 1x MPPT Solar Charge Controller
- 4x Corner connections
- 4x Screws for controller casing
- 1x English manual