GEYA SUL181h

Contents

GEYA SUL181h Mechanical Timer Switch User Manual

Model: SUL181h

Brand: GEYA

1. Product Overview

The GEYA SUL181h is a mechanical 24-hour programmable timer switch designed for DIN rail mounting. It provides reliable time control for various electrical applications, allowing for automatic switching ON and OFF of connected devices. This timer switch features a wide operating voltage range of 100-240V and a built-in battery for power reserve, ensuring continued operation even during power outages.

GEYA SUL181h Mechanical Timer Switch front view

Figure 1: GEYA SUL181h Mechanical Timer Switch

2. Specifications

AttributeValue
Model NumberSUL181h
TheoryMechanical
UseTimer Switch, Automatic Cycle
Operating VoltageAC 100-240V 50-60Hz
Rated Frequency50/60Hz
Power Consumption2.5VA
Contact Capacity16A / 250VAC (Resistive Load)
Lamp Load Capacity1000W
Inductive Load Capacity3A / 250VAC (cos=0.6)
Contact Resistance< 50MΩ
Insulation Resistance> 100MΩ
Operating Temperature-10°C to +55°C
Accuracy< 2S/day at 25°C
Full Timing Range24 hours
Minimum Setting Unit30 Minutes
Setup Times48 times (30 minutes/time)
Working Reserve Time150 hours (after recharging 24 hours)
Installation ModeDIN rail mounting
CertificationCE

Dimensions

GEYA SUL181h Timer Switch Dimensions

Figure 2: Dimensions of SUL181h (Unit: mm)

3. Installation

The GEYA SUL181h timer switch is designed for DIN rail mounting. Ensure all power is disconnected before installation. Electrical equipment should only be installed and assembled by qualified electricians.

Wiring Connection

Follow the connection diagram carefully. Connect the power supply (UE) to the appropriate terminals and the load to the output terminals. The operating voltage is 100-240V AC, 45-60Hz.

GEYA SUL181h Timer Switch Connection Diagram

Figure 3: Connection Diagram for SUL181h

Wiring Details:

  • Connect the live (L) and neutral (N) wires of the 100-240V AC power supply to the input terminals as indicated.
  • Connect the load (e.g., a lamp) to the output terminals. Ensure the load's power requirements do not exceed the timer switch's contact capacity.
  • Always double-check all connections for tightness and correctness before restoring power.

4. Operating Instructions

The SUL181h timer switch allows for both manual override and programmable 24-hour operation.

Manual Control ON/OFF (Override Control)

To manually control the switch, turn the control axis in the direction of the arrow by one notch. This will switch the device ON or OFF. The manual control is automatically overridden by the next scheduled automatic program sequence.

Manual Control ON/OFF Diagram

Figure 4: Manual Control ON/OFF

Permanent ON/OFF

To set permanent control, move the hand lever to 'Perm'. This enables permanent ON or OFF. Turning the hand lever to 'Auto' terminates the permanent control, and the automatic program sequence resumes. The actual switch position is maintained until the next counteracting command of the automatic program sequence is triggered. An immediate correction can be carried out by means of the manual control (override control).

Permanent ON/OFF Diagram

Figure 5: Permanent ON/OFF Control

24-Hour Programming

The timer allows for 24-hour programming with a minimum setting unit of 30 minutes and up to 48 ON/OFF times per day. To program, push the segments on the dial inwards for the desired ON periods and leave them outwards for OFF periods. Each segment represents 30 minutes.

24-hour Programming Diagram

Figure 6: 24-Hour Programming

5. Maintenance

The GEYA SUL181h timer switch requires minimal maintenance. Keep the device clean and free from dust and moisture. Periodically check the wiring connections to ensure they are secure. No user-serviceable parts are inside. For any repairs, contact a qualified technician.

6. Troubleshooting

  • Device not switching ON/OFF as programmed: Check the program settings on the dial. Ensure the current time is correctly set. Verify the manual override switch is in the 'Auto' position.
  • No power to the device: Check the main power supply and all wiring connections. Ensure the operating voltage is within the specified range (100-240V).
  • Timer not keeping accurate time: The device has a working reserve time of 150 hours after 24 hours of recharging. If the device has been without power for an extended period, allow it to recharge for 24 hours while connected to power.
  • Overheating: Ensure the load connected does not exceed the maximum contact capacity.

7. User Tips

  • For optimal performance, ensure the timer is installed in a location with stable temperature and humidity, within the specified operating temperature range.
  • When setting the current time, rotate the dial clockwise until the correct time aligns with the indicator.
  • Use the manual override function sparingly to avoid confusion with programmed settings.
  • Consider the type of load (resistive vs. inductive) when connecting devices to ensure it stays within the timer's capacity.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.