PowMr POW-HVM4.2M-24V-N

Contents

POW-HVM4.2M-24V-N Solar Inverter User Manual

Model: POW-HVM4.2M-24V-N

1. Introduction

This multi-functional hybrid solar inverter integrates a high-efficiency photovoltaic inverter with intelligent battery management technology. It is designed to provide a stable power supply, reducing grid dependence, suitable for both urban and remote areas. Featuring multiple power supply modes, easy button operation, and an LCD screen for monitoring, this product offers green, stable, and sustainable power management.

Front view of the POW-HVM4.2M-24V-N Solar Inverter
Figure 1: Front view of the POW-HVM4.2M-24V-N Solar Inverter.

2. Safety Information

Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure all wiring is performed by qualified personnel.
  • Do not attempt to repair the unit yourself. Refer to qualified service personnel.
  • Keep the inverter away from flammable materials and ensure adequate ventilation.
  • Ensure proper grounding of the unit.
  • Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
  • Observe the warning label on the unit: "Do not connect the battery after the utility is turned on."
Close-up of the power switch and warning label on the inverter
Figure 2: Power switch and warning label.

3. Product Overview

The POW-HVM4.2M-24V-N is a robust hybrid solar inverter constructed from durable aluminum alloy. It features a clear LCD display and intuitive button controls for easy configuration and monitoring.

3.1 Key Features

  • High-quality Material: Made of durable and rustproof aluminum alloy for long service life.
  • Stable Performance: 4200W high-power pure sine wave output for various home and office loads.
  • Multiple Output Modes: Configurable modes including solar priority, utility priority, and SBU mode.
  • Safety Guarantee: Equipped with overload and over-temperature protection, and a buzzer alarm with code display for fault diagnosis.
  • Configurable Parameters: Input voltage range and battery charging current can be configured via the LCD display.
  • Thoughtful Battery Setting: Compatible with 24V liquid-rich lead-acid and lithium batteries, featuring a battery equalization mode to maintain battery capacity and extend life.
  • Excellent Heat Dissipation: Heat dissipation holes and a built-in fan prevent overheating.

3.2 Components and Connections

The inverter features various ports for connecting solar panels, batteries, AC input, and AC loads.

Bottom view of the inverter showing all connection ports
Figure 3: Bottom view showing connection ports.

Connection Ports:

  • AC IN: Alternating Current Input (Utility Grid)
  • MAIN OUT: Main Alternating Current Output
  • SECOND OUT: Second Alternating Current Output
  • BMS: Battery Management System communication port
  • WIFI: Wi-Fi communication port
  • RS485: Serial communication port
  • RS232: Serial communication port
  • BATTERY (+/-): Battery connection terminals
  • PV IN (+/-): Photovoltaic (Solar Panel) Input terminals

3.3 LCD Display and Control Buttons

The LCD display provides real-time operational status and allows for parameter configuration using the control buttons.

Close-up of the LCD display and control buttons (ESC, UP, DOWN, ENTER)
Figure 4: LCD display and control buttons.

Buttons:

  • ESC: Exit or go back.
  • UP: Navigate up or increase value.
  • DOWN: Navigate down or decrease value.
  • ENTER: Confirm selection or enter menu.

4. Setup

Proper installation is crucial for the safe and efficient operation of your solar inverter. It is highly recommended that installation and wiring be performed by a certified electrician or solar professional.

4.1 Unpacking and Inspection

  1. Carefully unpack the inverter and all accessories.
  2. Inspect the unit for any physical damage. If damage is found, contact your supplier immediately.
  3. Verify that all items listed in the package contents are present.

4.2 Mounting the Inverter

  • Choose a suitable location for wall-mounting. The location should be dry, well-ventilated, and protected from direct sunlight, rain, and dust.
  • Ensure there is sufficient clearance around the inverter for proper airflow and heat dissipation.
  • Use appropriate screws and anchors to securely mount the inverter to a sturdy wall surface.
Image showing the dimensions of the inverter for mounting reference
Figure 5: Inverter dimensions for mounting.

4.3 Wiring Connections

WARNING: All wiring must be done with power disconnected from all sources (PV, battery, AC input). Incorrect wiring can cause severe damage to the inverter, batteries, and connected appliances, and poses a risk of electric shock.

  1. Battery Connection: Connect the battery cables to the BATTERY (+/-) terminals. Ensure correct polarity. Refer to the warning: "Do not connect the battery after the utility is turned on."
  2. PV Input Connection: Connect the solar panel cables to the PV IN (+/-) terminals. Observe correct polarity and ensure PV input voltage is within the specified range.
  3. AC Input Connection (Optional): If connecting to the utility grid, connect the AC input cable to the AC IN (L, N) terminals.
  4. AC Output Connection: Connect your loads to the MAIN OUT (L, N) and SECOND OUT (L, N) terminals.
  5. Communication Ports: Connect BMS, WIFI, RS485, or RS232 cables as required for monitoring or advanced control.
  6. Grounding: Ensure the inverter is properly grounded according to local electrical codes.

5. Operating Instructions

5.1 Powering On/Off

  1. Power On: After all connections are securely made and verified, turn on the battery breaker first, then the PV array breaker (if applicable), and finally the AC input breaker (if applicable). Press the power button on the side of the inverter. The LCD display will light up.
  2. Power Off: Reverse the power-on sequence. First, turn off the AC output breaker, then the AC input breaker, followed by the PV array breaker, and finally the battery breaker. Press and hold the power button until the unit shuts down.

5.2 LCD Display and Settings

The LCD display provides real-time information about the system status, including input voltage, output voltage, battery charge, and load percentage. Use the ESC, UP, DOWN, and ENTER buttons to navigate through menus and configure settings.

  • Monitoring: The default screen displays key operational parameters.
  • Parameter Configuration: Access the settings menu to adjust parameters such as:
    • Output mode (Solar Priority, Utility Priority, SBU Mode)
    • Input voltage range for home appliances or personal computers
    • Battery charging current
    • Battery equalization settings

5.3 Operating Modes

  • Solar Priority: The inverter prioritizes solar power to charge batteries and supply loads. Utility power is used only when solar power is insufficient.
  • Utility Priority: The inverter prioritizes utility power to supply loads and charge batteries. Solar power is used as a backup.
  • SBU Mode (Solar-Battery-Utility): Solar power is the primary source for loads and battery charging. If solar power is insufficient, battery power is used. If both solar and battery power are low, utility power is used.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter and ensure the ventilation openings are free from dust and debris. Use a dry, soft cloth. Do not use liquid cleaners.
  • Connection Check: Annually inspect all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
  • Battery Inspection: If using liquid-rich lead-acid batteries, check electrolyte levels and specific gravity regularly. Ensure battery terminals are clean and free of corrosion.
  • Environmental Check: Ensure the operating environment remains within the specified temperature range (-10-50℃) and is free from excessive humidity.

7. Troubleshooting

The inverter is equipped with a buzzer alarm and code display to help identify faults. Refer to the user manual for a complete list of error codes and their solutions.

SymptomPossible CauseSolution
Inverter not turning onNo battery power, loose connections, power button not pressed.Check battery connections and charge, ensure all breakers are on, press power button.
No AC outputOverload, short circuit, battery low, output mode setting.Reduce load, check for short circuits, charge battery, verify output mode settings.
Buzzer alarm sounds with error codeInternal fault, over-temperature, overload, battery issue.Note the error code, refer to the detailed manual for specific code meaning and troubleshooting steps. Ensure proper ventilation.
PV input not charging batteryPV panels not connected, insufficient sunlight, PV voltage out of range, MPPT fault.Check PV connections, ensure adequate sunlight, verify PV voltage, consult manual for MPPT issues.

8. User Tips

  • AC Input Necessity: While this is an off-grid inverter, the AC input (utility grid) is not strictly necessary for operation if you have sufficient solar and battery capacity. However, it provides a reliable backup and charging source, especially during prolonged periods of low solar irradiance. The inverter can be configured to prioritize solar, battery, or utility power based on your needs.
  • Battery Equalization: Utilize the battery equalization mode periodically, especially for liquid-rich lead-acid batteries, to maintain cell balance and extend battery lifespan.
  • Monitoring: Regularly check the LCD display for system status and any warning indicators to ensure optimal performance and prevent potential issues.

9. Specifications

Product label with detailed specifications for the inverter
Figure 6: Product label with detailed specifications.
CategoryParameterValue
GeneralModelPOW-HVM4.2M-24V-N
ColorGrey and Black
Operating Temperature Range-10-50℃ / 14-122℉
MaterialAluminum Alloy
Screen TypeLCD
Mount TypeWall-mounted
PV InputNominal Operating Voltage240Vdc
Vmax PV500Vdc
PV Input Voltage Range60-450Vdc
Imax PV18A
Full Load MPPT Range240-450Vdc
Maximum PV Input Power6200W
Maximum Solar Charging Current120A
GRID/AC OutputNominal Output Voltage220/230/240Vac
Feed-in Grid Voltage Range195-253Vac
Feed-in Grid Frequency Range50±1Hz
Nominal Output Current18.2A
Power Factor Range>0.99
Maximum Conversion Efficiency(DC/AC)97%
Nominal Operating Frequency50/60Hz
Two Load Output PowerFull Load4200W
Maximum Main Load4200W
Maximum Second Load1400W
Main Load Cut-Off Voltage26Vdc
AC InputNominal Operating Voltage230Vac
Maximum Input Current30A
Nominal Operating Frequency50/60Hz
Surge Power8400VA
Maximum AC Charging Current100A
BatteryBattery Voltage24Vdc
Maximum Battery Current175A
PhysicalProduct Size (L*H*W)42.5 x 50.5 x 18.5 cm / 16.7 x 19.88 x 7.28 in
Package Size46.5 x 32.5 x 16 cm / 18.3 x 12.8 x 6.3 in
Gross Weight9 kg / 19.84 lbs

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Package Contents:

  • 1 x Hybrid Solar Inverter
  • 1 x English User Manual
The inverter shown next to its included user manual
Figure 7: Inverter and included user manual.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.