MYAMi MPPT60A

Contents

MYAMi MPPT Solar Charge Controller User Manual

Model: MPPT60A

1. Introduction

This MYAMi MPPT Solar Charge Controller is designed for solar off-grid power generation systems to automatically regulate battery charging and discharging. It utilizes innovative Maximum Power Point Tracking (MPPT) technology to significantly improve the energy utilization efficiency of solar energy systems, achieving a conversion efficiency of up to 97%. The controller quickly scans the entire I-V curve to efficiently track the maximum power point of solar cell modules.

The controller supports a wide range of battery types, including lead-acid (sealed, colloidal, and open type) and lithium battery series. It features comprehensive self-test functions and electronic protection to prevent damage from installation errors and system failures. Its low voltage disconnect (LVD) function prevents over-discharge, extending battery life and improving overall system performance.

2. Product Features

2.1 Major Advantages

MYAMi MPPT Solar Charge Controller with 6 Major Advantages listed.

Image: MYAMi MPPT Solar Charge Controller highlighting its six major advantages.

  1. Comes with lithium battery activation function.
  2. Supports 0-230V ultra-wide voltage access.
  3. 12-96V battery universal compatibility.
  4. Large screen display for easy monitoring.
  5. Enables charging even on rainy days.
  6. Adjustable parameters for customized operation.

2.2 Multiple Protection Functions

MYAMi MPPT Solar Charge Controller illustrating 8-in-1 Multiple Protection features.

Image: Diagram showing the 8-in-1 multiple protection features of the MYAMi MPPT Solar Charge Controller.

The controller incorporates 8-in-1 protection features to ensure the safety and longevity of your solar system:

  • Over-Current Protection (OCP)
  • Fault Alarm
  • Over-Load Protection (OLP)
  • Under-voltage Protection
  • Over-Charging Protection
  • Short-Circuit Protection (SCP)
  • Over-voltage Protection
  • Over-Temperature Protection

3. Specifications

MYAMi MPPT Solar Charge Controller with detailed specifications table.

Image: MYAMi MPPT Solar Charge Controller with a table of its intelligent and efficient specifications.

FeatureSpecification
Model NumberMY-MPPT60A
ApplicationSolar System Controller
System Voltage Automatic Recognition12V/24V/36V/48V/60V/72V/84V/96V
Controller TypeMPPT
Rated/Maximum Charging Current60A
Charge Mode10-60A Setting
MPPT Efficiency97%
Battery Type CompatibilityLead acid (Sealed, Gel, Open), Phosphate, Ternary battery
DisplayLCD Display
Protection FeaturesOCP/OLP/SCP (Over-Current, Over-Load, Short-Circuit) and others
Is Smart DeviceNo
High-concerned chemicalNone
OriginMainland China
Dimensions (L x W x H)26.5cm x 18cm x 9.2cm
Weight2.8kg ±0.2kg

3.1 Input Maximum Power by System Voltage

System VoltageInput Maximum Power (W)
12V828W
24V1656W
36V2484W
48V3312W
60V4140W
72V4968W
84V5796W
96V6624W

4. Package Contents

MYAMi MPPT Solar Charge Controller packaging and contents.

Image: The MYAMi MPPT Solar Charge Controller shown with its retail packaging and included manual.

Upon opening the package, please verify that all items are present and in good condition:

  • MYAMi MPPT Solar Charge Controller (Model: MY-MPPT60A)
  • User Manual
  • (Other small accessories may be included, please check packaging)

5. Setup and Installation

Before installation, ensure the controller is placed in a well-ventilated area, away from direct sunlight, high temperatures, and moisture. Mount the controller vertically on a wall or suitable surface to allow for proper heat dissipation by the intelligent cooling fan.

5.1 Connection Diagram

Rear and bottom view of MYAMi MPPT Solar Charge Controller showing connection terminals and cooling fan.

Image: Rear and bottom view of the MYAMi MPPT Solar Charge Controller, indicating connection points for solar panels, battery, temperature sensor, and RS485 port, along with the intelligent cooling fan.

Follow the connection order below to prevent damage to the controller or system components:

  1. Connect the Battery: Connect the battery to the 'BATTERY' terminals (+ and -) on the controller. Ensure correct polarity. The controller will automatically recognize the system voltage (12V/24V/36V/48V/60V/72V/84V/96V).
  2. Connect the Solar Panels: Connect the solar panel array to the 'SOLAR PANEL' terminals (+ and -). Ensure correct polarity. The controller's MPPT algorithm will optimize charging.
  3. Connect the Temperature Sensor: Plug the temperature sensor into the 'TEMP' port. This sensor helps the controller adjust charging parameters based on battery temperature.
  4. RS485 Communication (Optional): If multi-machine communication or remote monitoring is desired, connect the RS485 cable to the 'RS485' port.

Important: Always connect the battery first, then the solar panels. Disconnect in the reverse order: solar panels first, then the battery.

6. Operating Instructions

MYAMi MPPT Solar Charge Controller, front view with display and buttons.

Image: Front view of the MYAMi MPPT Solar Charge Controller, showing the LCD display and control buttons.

The controller features an LCD display and several buttons for monitoring and adjusting parameters:

  • LCD Display: Shows real-time system status, including battery voltage, charging current, PV voltage, and error codes.
  • SET/BACK Button: Enters/exits the settings menu or goes back to the previous screen.
  • UP Button: Navigates up through menu options or increases parameter values.
  • DOWN Button: Navigates down through menu options or decreases parameter values.
  • CONFIRM Button: Confirms selections or saves parameter changes.

6.1 Basic Monitoring

Once connected, the LCD display will show the current operating status. You can cycle through different display screens using the UP/DOWN buttons to view various parameters such as PV voltage, battery voltage, charging current, and load status.

6.2 Parameter Adjustment

To adjust parameters (e.g., battery type, charging limits), press the SET/BACK button to enter the settings menu. Use the UP/DOWN buttons to navigate through options and the CONFIRM button to select. Adjust values with UP/DOWN and save with CONFIRM. Refer to the detailed instructions in the included physical manual for specific parameter settings for different battery types.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your MYAMi MPPT Solar Charge Controller:

  • Cleaning: Periodically clean the controller's exterior with a dry cloth to remove dust and dirt. Ensure the cooling fan and vents are free from obstructions.
  • Connection Checks: Annually, inspect all wiring connections (battery, solar panels, temperature sensor, RS485) to ensure they are tight and free from corrosion. Loose connections can cause overheating or system malfunctions.
  • Environmental Conditions: Ensure the controller remains in a dry, well-ventilated environment within its specified operating temperature range.
  • Firmware Updates: Check the manufacturer's website periodically for any available firmware updates that may improve performance or add features.

8. Troubleshooting

The controller's LCD display will show fault alarms or error codes if an issue occurs. Refer to the table below for common issues and their potential solutions:

Problem/AlarmPossible CauseSolution
No Display/No PowerBattery not connected or low voltage.Check battery connections and ensure battery voltage is above the minimum operating threshold.
Over-Current Protection (OCP)Excessive current draw from the load or charging.Reduce load, check for short circuits in wiring, or verify solar panel input is within limits.
Over-Load Protection (OLP)Connected load exceeds controller's rated capacity.Reduce the connected load or replace with a higher-rated controller.
Short-Circuit Protection (SCP)Short circuit detected in load or wiring.Identify and clear the short circuit.
Over-Charging ProtectionBattery voltage exceeds the set overcharge limit.Verify battery type and charging parameters are correctly set.
Under-voltage ProtectionBattery voltage has dropped below the low voltage disconnect (LVD) threshold.Charge the battery. Reduce load or increase solar input.
Over-voltage ProtectionInput voltage from solar panels is too high.Check solar panel configuration and ensure PV open circuit voltage (Voc) does not exceed controller limits.
Over-Temperature ProtectionController internal temperature is too high.Ensure adequate ventilation, clear any obstructions from the cooling fan, or reduce ambient temperature.
Charging on Rainy DaysReduced charging efficiency.This is normal due to lower solar irradiance. The controller is designed to optimize charging even in low light conditions.

If the problem persists after attempting these solutions, please contact customer support.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact the MYAMi Official Store directly. Ensure you have your product model number (MY-MPPT60A) and purchase details ready when seeking support.

10. Application Scenarios

MYAMi MPPT Solar Charge Controller in an application scenario with solar panels.

Image: MYAMi MPPT Solar Charge Controller depicted in a typical off-grid solar power generation setup with solar panels on a rooftop.

The MYAMi MPPT Solar Charge Controller is versatile and mainly used in various off-grid applications, including:

  • Off-grid power generation systems
  • Monitoring systems
  • Solar home systems
  • Telecommunications infrastructure
  • Forest fire protection applications
  • Solar street light systems
  • Recreation Vehicles (RVs)
  • Boats
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.