1. Introduction
The KILEWS KTM-150 is a high-precision digital torque meter designed for accurate measurement of torque in various applications, particularly with electric batch torque testers. It features a clear digital display for easy reading and simple operation. This manual provides essential information for the safe and effective use, maintenance, and troubleshooting of your KTM-150 device.

2. Safety Precautions
Please read and understand the following safety precautions before operating the device to ensure safe and correct usage:
- Always read the instruction manual thoroughly before using the device.
- Do not exceed 120% of the permissible load capacity of the device.
- Avoid using the device for any impact measurements.
- If the LCD display turns off after 10 minutes, turn the power OFF and then ON again to reset it.
3. Product Components and Overview
The KTM-150 comes with essential accessories for various torque testing needs. Familiarize yourself with the main unit and its components.


Key Components:
- Data Output (USB)
- Power Switch
- Charging Indicator (LED Red)
- AC Charging Port
- Analog Output
- Fixed Knob
- Clear Button
- Memory/Output Button
- Average Function Button
- Measurement Mode Selection Button
- Test Base
- Function Setting Key
- Measurement Unit Switching Key
- Up Key
- Down Key
- NG Light (No Good)
- GOOD Light
- LCD Display
- System Reset (RESET)
4. Setup
4.1 Initial Charging
Before first use, ensure the device is fully charged. Connect the AC charger to the AC Charging Port (4) and a power outlet. The Charging Indicator (3) will illuminate. Refer to the specifications for charging time.
4.2 Power On/Off
To power on the device, toggle the Power Switch (2) to the 'ON' position. To power off, toggle it to 'OFF'.
4.3 Attaching Test Base and Accessories
Secure the Test Base (11) to the main unit. Select the appropriate buffer accessories (as shown in Figure 2) for your specific measurement needs and attach them to the test base. Ensure they are firmly seated.
5. Operating Instructions
5.1 Basic Measurement
- Power on the device using the Power Switch (2).
- Select the desired measurement unit using the Measurement Unit Switching Key (13). Available units typically include kgf.cm, Lbf.in, and N.m.
- Place the object to be tested onto the Test Base (11) or attach it using appropriate accessories.
- Apply torque to the object. The LCD Display (18) will show the real-time torque value.
- The GOOD (17) or NG (16) lights may illuminate based on pre-set torque limits (if configured).
5.2 Setting Functions and Modes
Use the Function Setting Key (12) to enter the setting menu. Navigate through options using the Up Key (14) and Down Key (15). The Measurement Mode Selection Button (10) allows switching between different measurement modes (e.g., peak hold, track mode, first peak mode).
5.3 Data Management
- Memory/Output (8): This button is used to save measurement data or output it.
- Average Function (9): Use this button to calculate the average of multiple measurements.
- Data Output (USB) (1): Connect the device to a computer via the USB port to transfer stored measurement data.
5.4 Resetting the Device
If the device malfunctions or the LCD display turns off, use the System Reset (RESET) (19) button or turn the power OFF and ON again.
6. Specifications
The following table details the technical specifications for the KILEWS KTM series, including the KTM-150 model:

| Parameter | KTM-250 | KTM-150 | KTM-15 | KTM-6 | KTM-50S |
|---|---|---|---|---|---|
| Measurement Range (lbf.in) | 3.0~217.0 | 1.5~130.0 | 0.15~13.00 | 0.02~8.0 | 0.5~50.0 |
| Measurement Range (kgf.cm) | 3.0~250.0 | 1.5~150.0 | 0.15~15.00 | 0.02~7.0 | 0.5~43.4 |
| Measurement Range (N.m) | 0.30~25.00 | 0.15~15.00 | 0.015~1.500 | 0.2~80.0 (cN.m) | 0.05~4.90 |
| Accuracy | ±0.5% | ||||
| Power Source | 4.8VDC (Ni-MH rechargeable battery 1.2V x 4 cell 1650mAh) | ||||
| Charging Time | 8 hours | ||||
| Battery Life (Full Charge) | Approx. 12 hours | ||||
| Battery Cycle Life | Rechargeable 300+ times | ||||
| External Dimensions (mm) | 229X102X80 (H) | 160X210X45 (H) | 230X125X65 (H) | 230X125X65 (H) | 230X125X65 (H) |
| Weight (kg) | 2.7 | 2.0 | 1.8 | 1.8 | 1.8 |
| Special Charger Input | AC100V-240V 50/60Hz | ||||
| Special Charger Output | DC12V 400mA | ||||
| Accessories (KTM-150) | Spring Test Fixture x3 (AJ-150 / AJ-50 / AJ-15K) | ||||
7. Maintenance
7.1 Cleaning
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents that could damage the casing or display.
7.2 Storage
Store the torque meter in its original case (Figure 5) in a dry, dust-free environment when not in use. Avoid extreme temperatures and humidity.

7.3 Battery Care
To prolong battery life, avoid fully discharging the battery frequently. Recharge the device when the battery indicator is low. If storing for extended periods, charge the battery to about 50% and recharge every few months.
8. Troubleshooting
- Device does not power on:
- Check if the battery is charged. Connect the charger and try again.
- Ensure the power switch is fully in the 'ON' position.
- LCD display turns off during operation:
- This is a normal power-saving feature if inactive for 10 minutes. Turn the power OFF and ON again to reset.
- Inaccurate readings:
- Ensure the correct measurement unit is selected.
- Verify that the load does not exceed 120% of the permissible load.
- Avoid impact measurements.
- Consider recalibration if issues persist (contact support).
- Data transfer issues:
- Ensure the USB cable is securely connected to both the device and the computer.
- Check computer's device manager for proper driver installation.
9. User Tips
- For repetitive tasks, utilize the average function to get a more consistent torque value.
- Regularly transfer data via USB to keep records and analyze trends.
- Always use the appropriate test base and accessories for the specific type of fastener or object being measured to ensure accuracy and prevent damage.
10. Warranty and Support
For technical support, service, or warranty inquiries, please contact KILEWS customer service or your local distributor. You may also reach out via the following contact information:
- WhatsApp: +8615074050449
- Email: b15773036137@163.com
Please have your model number (KTM-150) and any relevant purchase information ready when contacting support.