SUSWE SU700

Contents

SUSWE SU700 Series Variable Frequency Drive User Manual

Model: SU700

Single-phase 220V Input to Three-phase 380V Output Frequency Converter

1. Introduction

Thank you for choosing the SUSWE SU700 series frequency converter. This manual provides essential information for the correct and safe use of this product. Please read it carefully before installation, operation, or maintenance, and keep it for future reference.

1.1 Safety Information and Notices

Safety notices in this manual are categorized as follows:

  • Danger: Indicates operations that, if not performed according to requirements, may cause serious injury or even death.
  • Attention: Indicates operations that, if not performed according to requirements, may cause medium or minor injury, or equipment damage.

It is crucial to operate this system strictly according to the safety notices provided. Any injury or loss resulting from non-compliance with these requirements is not the responsibility of the manufacturer.

2. Specifications

The SU700 series VFD is designed for motor speed control, converting single-phase 220V input to three-phase 380V output. It features high performance and comes with CE and FCC certifications.

2.1 Product Naming Rules

The model naming convention for the SU800/900 series (which includes SU700) is structured as follows:

SU800/900 - 2R2 - G3
  • Voltage Grade:
    • G1 = Input single-phase 220V, output three-phase 380V
    • G2 = Input single-phase 220V, output three-phase 220V
    • G3 = Input single-phase 380V, output three-phase 380V
  • Power Grade:
    • 0R75 = 0.75KW
    • 1R5 = 1.5KW
    • 2R2 = 2.2KW
    • ... and so on for higher power ratings.
Inverter Product Description and Naming Rules
Figure 2.1: Inverter Product Description and Naming Rules. This image illustrates the front, front side, and rear side views of the inverter, along with a diagram explaining the naming rules for the FK-700A series, including voltage and power grades.

2.2 General Specifications

Table 2.1: General Product Specifications
AttributeValue
Brand NameSUSWE
Model NumberSU700 (FK700 series)
TypeDC/AC Inverter (Variable Frequency Drive)
Input VoltageSingle-phase 220V
Output VoltageThree-phase 380V
Output Frequency50-60HZ
Output Power Range0.75KW - 22KW (Specific models: 11KW, 15KW, 18.5KW, 22KW)
Output Current (for 11KW model)25A
Weight (for 11KW model)3.1kg
Dimensions (for 11KW model)240.5 x 125 x 166 mm
OriginMainland China
CertificationCE, FCC, RoHS
Product Parameters for 11KW VFD
Figure 2.2: Detailed product parameters for the FK700B-11R0G1 (11KW) model, including input/output specifications, current, dimensions, and weight.
Frequency Converter Series Index Table
Figure 2.3: Comprehensive table listing various FK700 series frequency converter models, their power supply capacity, rated input/output currents, and adapted motor power (kW/HP) for single-phase 220V to three-phase 380V, single-phase 220V to three-phase 220V, and three-phase 380V to three-phase 380V configurations.
VFD Sizes by Power Rating
Figure 2.4: Visual comparison of VFD unit sizes corresponding to different power ratings (0.75KW-2.2KW, 4KW-7.5KW, 11KW-15KW, 18.5KW-22KW).

3. Installation

3.1 Main Circuit Terminals and Wiring

The main circuit terminals are used for power input and motor output connections. Ensure proper grounding for safety.

Table 3.1: Main Circuit Terminal Instructions
Terminal MarksNameInstruction
R, S, T/L, NPower supply input terminalsConnection point of three-phase 380V / single-phase 220VAC power supply
P+, PBBrake electric resistance connect terminalsConnect brake electric resistance
U, V, WFrequency converter output terminalsConnect three-phase motor
Grounding SymbolGrounding terminalsGrounding terminals

3.2 Wiring Method of Frequency Converter Control Circuit

The control circuit wiring for all 800/900 series inverters is identical. The diagram below illustrates a typical three-phase 380V converter wiring. The main loop terminals are indicated by a square, and control loop terminals by a circle.

Wiring Diagram for Frequency Converter Control Circuit
Figure 3.1: Wiring diagram for the frequency converter control circuit, showing connections for power input (RST), motor output (UVW), ground, and optional braking resistance. It also details the multifunctional digital input terminals (X1-X4, HDI), analog inputs (AI1, AI2), analog outputs (AO1, AO2), open collector output (Y1), high-speed pulse output (HDO), relay outputs (KIA, KIB, KIC), and RS485 communication (A+, B-).

3.3 Control Terminals Instruction

The control circuit terminals allow for various input and output signals. Refer to the detailed function instruction table for each terminal.

Table 3.2: Control Terminal Function Instruction (Partial)
CategoryTerminal SymbolTerminal NameFunction Instruction (Summary)
Power Supply10V - GNDOuter connect 10V power supply150mA supply for external electric potential devices (1kΩ ~ 5kΩ)
24V - COMOuter connect 24V power supply+24V supply for digital I/O and sensor (max 200mA)
Analog InputAI1-GNDAnalog quantity input terminal 1DC 0-10V / 0-20mA input, 22kΩ for voltage, 500Ω for current
AI2-GNDAnalog quantity input terminal 2DC 0-10V / 0-20mA input, 22kΩ for voltage, 500Ω for current
Analog OutputAO1-GNDAnalog quantity input terminal 10-10V voltage output, 0-20mA / 4-20mA current output
AO2-GNDAnalog quantity input terminal 20-10V voltage output (no current output function)
Digital InputX1-COMDigit input 1Digital inputs X1-X4, HDI (X5) can also be high-speed pulse input (up to 50KHz). Input voltage range: 5V-30V.
X2-COMDigit input 2
X3-COMDigit input 3
X4-COMDigit input 4
HDI-COM (X5)Digit input 5
CommunicationA+ B-RS485 communicationA+ is positive, B- is negative input of 485 communication signal
Digital OutputY1-COMCollector open circuit outputCollector open circuit output terminal
HDO-COMHigh speed pulse outputHigh-speed pulse output up to 50KHz
K1A-K1B-K1C, K2A-K2B-K2CElectric relay 1 & 2 terminalContact drive capacity: AC250V, 3A; DC 30V, 1A
VFD with Detachable Panel Removed
Figure 3.2: The VFD unit with its detachable operation panel removed, showing the connection port for the panel.
Internal Circuit Board of VFD
Figure 3.3: An internal view of the VFD's circuit board, highlighting the quality of components and design.

3.4 Signal Input Terminal Wiring Instruction

Analog voltage signals are susceptible to external interference. Therefore, it is recommended to use shielded cables, and keep cable lengths as short as possible, ideally not exceeding 20 meters. For analog signal sources, consider adding filter wave electric capacitors or iron-oxygen magnetism to areas where signals are severely disturbed.

4. Operation

4.1 Operation and Display Interface

The operating panel allows you to modify function parameters, monitor the VFD's working status, and control its operation (start/stop). The layout and function areas are shown below.

Human-Machine Interactive Button Panel
Figure 4.1: Schematic diagram of the operation panel, detailing the display screen, knob, programming key, incremental key, run key, shift key, stop key, decrement key, and various indicators for command, operation, forward/reverse, tuning/fault, frequency, current, and voltage.

4.2 Function Indicator Lamp Instruction

  • RUN: Extinguished means VFD is stopped; lit means VFD is running.
  • LOCAL/REMOTE:
    • Extinguished: Panel start-stop control.
    • Normally lighting: Terminal start-stop control.
    • Flashing: Communication start-stop control.
  • FWD/REV: Lit indicates forward operation.
  • TUNE/TC: Lit indicates torque control mode; slow flashing indicates tune status; quick flashing indicates failure status.

4.3 Unit Indicator Lamp

Table 4.1: Unit Indicator Lamp Meanings
IndicatorUnit
HzFrequency unit
ACurrent unit
VVoltage unit
RPM (Hz+A)Speed unit
% (A+V)Percentage

4.4 Digit Display Area

The 5-bit LED display shows the setting frequency, output frequency, various monitoring data, and alarm codes.

4.5 Keyboard Button Description

Table 4.2: Keyboard Button Functions
KeyKey NameFunction
PRGProgramming KeyEnter or exit Level I menu.
ENTERConfirm KeyEnter menu tableau, confirm parameter settings.
▲Increment KeyIncrement data or function code.
▼Decrement KeyDecrement data or function code.
◀Shift KeySelect display parameters or modify bit of parameter.
RUNRunning KeyStart operation under keyboard control.
STOP/RESStop/Reset KeyStop running operation; reset during failure alarm. Functionality may be restrained by P7-02.
MF.KMultiply Functions Select KeySelect function shift according to P7-01.

4.6 Operation Demonstration

Watch this video for a visual guide on how to operate the VFD for motor speed control.

Video 4.1: Demonstration of VFD motor speed control. This video shows the process of turning on the power, starting the converter, adjusting motor speed with the control knob, slowing down, and stopping the motor.

5. Parameter Settings

The SU700 series VFD offers a wide range of configurable parameters organized into various groups (F0, F1, P2, P3, P4, P5, P6, P7, P8, P9, PA, PB, PC, PD, PP, A5, b0, U0). These parameters control aspects such as basic running, motor characteristics, vector control, V/F control, input/output terminals, output terminals, start/stop control, keyboard/display, assist functions, failure/protection, PID functions, swing frequency, multi-section order, communication, control optimization, constant pressure water supply, and monitoring.

For a complete and detailed list of all parameters, their settings, and functions, please refer to the full user manual (PDF) available at: User Manual (PDF).

5.1 Key Parameter Groups Overview

  • F0 Group: Basic running parameters (e.g., G/P model, order source select).
  • F1 Group: Motor parameters (e.g., motor rated power, voltage, current, frequency, speed).
  • P2 Group: Vector parameters (e.g., speed ring ratio gain, shift frequency).
  • P3 Group: V/F control parameters (e.g., V/F curve setting, torque promote).
  • P4 Group: Input terminal parameters (e.g., terminal function select, filter wave time).
  • P5 Group: Output terminal parameters (e.g., HDO output mode, electric relay function select).
  • P6 Group: Start and stop control parameters (e.g., startup mode, accelerate/moderate methods).
  • P7 Group: Keyboard and display parameters (e.g., MF.K key function, LED running/stop display).
  • P8 Group: Assist function parameters (e.g., crawl running frequency, jump frequency).
  • P9 Group: Failure and protection parameters (e.g., motor overload protection, fault action selection).
  • PA Group: PID function parameters (e.g., PID setting source, ratio gain).
  • PB Group: Swing frequency, length, and counting parameters.
  • PC Group: Multi-section order and simple PLC parameters.
  • PD Group: Communication parameters (e.g., baud rate, data format, machine address).
  • PP Group: Function code management parameters (e.g., user password, parameter initialize).
  • A5 Group: Control optimize parameters (e.g., PWM modulate method, dead zone compensate).
  • b0 Group: Intelligent constant pressure water supply parameters.
  • U0 Group: Monitor parameters (read-only values for various operational states).

Important Note: Some parameters cannot be changed while the frequency converter is running, and some cannot be changed regardless of the state. Always refer to the PDF manual for specific parameter ranges, units, and related instructions.

5.2 Industry Application Macros (P0-29)

The VFD includes predefined macros (P0-29) to simplify configuration for common industrial applications. While these macros reduce the number of parameters to configure, it's important to understand that not all parameters are fully considered. If issues arise, specific parameter adjustments may be necessary based on your experience.

  • Restore Factory Parameter Macro (P0-29=10000): This macro restores the VFD to its ex-factory default values, excluding motor parameters. It is recommended to perform this reset before applying any other industry application macro.
  • Constant Pressure Water Supply Macro: This macro (e.g., P0-29=1 for single pump, P0-29=2 for one drag three, P0-29=3 for one drag five) is designed for efficient constant pressure water supply control. It offers strong pressure regulation, rapid response, and energy saving. It requires inputting sensor range and target pressure values.
  • Engraving Machine Macro (P0-29=400HZ:24000 transfer): This macro is for engraving machine applications, typically involving AI1 input for speed and X1 terminal for start/stop. It requires connecting a brake resistance and careful adjustment of over-voltage stall gain if brake over-voltage occurs.

6. Troubleshooting

The SU700 series frequency converter provides 24 types of warning information and protection functions. When a protection function is triggered, the VFD will stop output, and the display panel will show a failure code. Use the information below to diagnose and resolve common issues.

6.1 Failure Alarms and Policies

Table 6.1: Common Failure Alarms and Solutions (Partial)
Failure NameFailure CodePossible ReasonTreatment Policies
Inverter unit protectionErr11. Frequency converter output circuit short circuit
2. Too long motor and frequency converter wiring
3. Overheat module
4. Internal wiring loosen
5. Abnormal main control/drive board
6. Abnormal mutation module
1. Solve outer failure
2. Install reactor/output filter wave device
3. Check air channel, fan
4. Plug in all wiring well
5. Seek technical support
Accelerate over currentErr21. Output circuit grounding/short circuit
2. Incorrect control method/parameter identification
3. Too short accelerate time
4. Manual torque rise/unsuitable V/F curve
5. Lower voltage
6. Starting rotating motor/sudden load
7. Smaller VFD model selected
1. Solve outer failure
2. Process motor parameter identification
3. Increase accelerate time
4. Adjust torque rise/V/F curve
5. Adjust voltage to normal range
6. Select speed tracing start/restart
7. Cancel sudden load
8. Select bigger power grade VFD
Power on but no indicationN/A (Visual)1. No power grid voltage or too low
2. Switch power supply failure on drive board
3. Rectification bridge damaged
4. Control board/keyboard/wiring broken
1. Check input power supply
2. Seek factory service
3. Check bus line voltage
4. Pull and insert main board pin socket again

For a comprehensive list of all failure codes, reasons, and treatment policies, please refer to Chapter 6 of the full user manual (PDF).

7. User Tips

  • VFD Sizing: When selecting a VFD, if the motor power is small, it is recommended to choose a VFD one level higher in power. If the motor load is large, consider choosing a VFD two levels higher in power to ensure optimal performance and longevity. For example, an 11KW VFD is generally suitable for a 7.5KW motor.
  • Control Mode: The SU700 series is a vector frequency inverter, offering advanced vector control for precise motor speed and torque regulation.
  • Solar Conversion: This inverter can be adapted for solar applications. If you intend to use it as a solar inverter, please contact customer service to discuss the specific requirements and the process for replacing the standard module with a solar-compatible module.

8. Warranty

The frequency converter comes with an 18-month warranty from the date of manufacture (as indicated by the bar code on the product). This warranty covers failures or damages under normal use conditions.

8.1 Conditions for Maintenance Fees

A reasonable maintenance fee will be charged for repairs after 18 months, or within the 18-month period if the damage is due to:

  • User's failure to comply with the provisions of the manual.
  • Damage caused by fire, flood, abnormal voltage, etc.
  • Damage caused by applying frequency converters to abnormal functions.

Relevant service costs will be calculated according to the manufacturer's standard rates, or as per any existing contract.

Multiple Certification Testing
Figure 8.1: Certifications for the VFD, including CE, FCC, and RoHS, ensuring compliance with international quality and safety standards.

9. Support

For any technical support inquiries, questions regarding product functionality, or assistance with troubleshooting, please contact our customer service team. Our professionals are dedicated to providing the best possible service.

You can also refer to the full user manual (PDF) for detailed information on parameters and advanced settings: User Manual (PDF).

10. Frequently Asked Questions (FAQ)

Q: What type of control does this VFD use (vector or scalar)?
A: The SU700 series is a vector frequency inverter, offering advanced vector control for precise motor speed and torque regulation.
Q: Can an 11KW VFD be used for a 7.5KW motor?
A: Yes, an 11KW VFD can be used for a 7.5KW motor. It is often recommended to select a VFD with a slightly higher power rating than the motor, especially for applications with heavy loads or frequent starts/stops, to ensure optimal performance and longevity.
Q: Can this VFD be converted to a solar inverter?
A: Yes, this VFD can be adapted for solar inverter applications. Please contact customer service to discuss the specific requirements and the process for replacing the standard module with a solar-compatible module.