DIGITEN FL-308D

Contents

DIGITEN FL-308D G3/8" Water Flow Sensor Instruction Manual

Food Grade POM Flow Hall Sensor 0.3-10L/Min

1. Introduction

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the DIGITEN FL-308D G3/8" Water Flow Sensor. This sensor is designed for accurate measurement of liquid flow in various applications.

2. Specifications

The DIGITEN FL-308D Water Flow Sensor features a robust design with food-grade POM material, ensuring safety and durability for a wide range of uses.

DIGITEN FL-308D Water Flow Sensor with specifications and wiring diagram

Figure 1: DIGITEN FL-308D Water Flow Sensor with key specifications and wiring details.

Table 1: Technical Specifications
ParameterValue
Model NumberFL-308D
External Thread DiameterG3/8"
Interior Diameter5.5mm
External Diameter9.5mm
Flow Range0.3-10 L/min
Frequency FormulaF = 23.6 * Q (L/min)
Pressure RangeWater pressure ≤0.8 MPa
Working Voltage RangeDC 5-18 V
Error± 3%
Storage Temperature-25℃ to +80℃
Storage Humidity25% to 95% RH
Output WaveformSquare Wave, pulse signal
Cable Length15cm
MaterialFood Grade POM

3. Key Features

  • Compact Design: Light, nimble outline, small in size, and easy to install.
  • Durable Construction: Bearings are used in the rotating part for reliable performance.
  • Hall Effect Sensor: Integrated magnetic hall effect sensor provides an electrical pulse output with every revolution.
  • Sealed Electronics: The hall effect sensor is sealed from the water pipe, ensuring safety and dryness of the electronic components.
  • Food Grade Material: Constructed from Food Grade POM, suitable for applications involving potable water.

4. Setup and Installation

4.1 Wiring Instructions

The sensor uses a three-wire connection system:

  • Red Wire: Connect to VCC (+) (Positive power supply, DC 5-18V).
  • Black Wire: Connect to GND (Ground).
  • Yellow Wire: Connect to Signal Output (Pulse signal).

4.2 Mechanical Installation

  1. Flow Direction: Install the sensor in accordance with the flow direction indicated on the product. Incorrect installation will result in no signal output.
  2. Filtering: A filter screen must be installed at the inlet of the sensor to prevent particles and debris from entering and potentially damaging the sensor or affecting its accuracy.
  3. Connection: Connect the G3/8" external threads to your plumbing system. Ensure a watertight seal using appropriate thread sealant or PTFE tape.
  4. Orientation: While the sensor can be installed in various orientations, ensure the rotating part is free to move without obstruction.

5. Operating Principles

The FL-308D water flow sensor operates on the Hall effect principle. As water flows through the sensor, it rotates an internal impeller. A magnetic Hall effect sensor detects the rotation of this impeller and generates a series of electrical pulses. The frequency of these pulses is directly proportional to the water flow rate.

The relationship between frequency (F) and flow rate (Q) is given by the formula:

F = 23.6 * Q (L/min)

Where:

  • F is the output pulse frequency in Hz.
  • Q is the flow rate in Liters per minute (L/min).

By measuring the output pulse frequency, you can accurately calculate the instantaneous water flow rate.

6. Maintenance

Regular maintenance helps ensure the longevity and accuracy of your water flow sensor.

  • Filter Screen: Periodically inspect and clean the filter screen installed at the sensor's inlet. Clogged filters can restrict flow and affect measurement accuracy.
  • Impeller Inspection: If you suspect an issue, carefully inspect the internal impeller for any debris or obstructions that might hinder its rotation.
  • Cleaning: For external cleaning, use a soft, damp cloth. Do not use harsh chemicals or abrasive materials that could damage the POM housing.
  • Storage: If storing the sensor for an extended period, ensure it is clean, dry, and kept within the specified storage temperature and humidity ranges (-25℃ to +80℃, 25% to 95% RH).

7. Troubleshooting

Table 2: Troubleshooting Guide
ProblemPossible CauseSolution
No signal outputIncorrect wiringVerify wiring: Red to VCC(+), Black to GND, Yellow to Signal.
No signal outputIncorrect installation directionEnsure the sensor is installed according to the flow direction arrow.
No signal outputNo water flow or flow below minimum range (0.3 L/min)Check water supply and ensure flow rate is within the specified range.
Inaccurate readingsClogged filter screen or internal debrisClean or replace the filter screen. Inspect the impeller for obstructions.
Inaccurate readingsPressure exceeding maximum (0.8 MPa)Ensure water pressure is within the specified limits. High pressure can damage the sensor.
Intermittent signalLoose electrical connectionsCheck and secure all wiring connections.

8. User Tips

To maximize the utility and lifespan of your DIGITEN FL-308D Water Flow Sensor, consider the following tips:

  • Application Versatility: This sensor is highly versatile and can be integrated into various systems such as water heaters, coffee machines, water purifiers, drinking fountains, beverage machines, and campus smart card equipment for precise flow monitoring.
  • Pre-filtering: Always use a pre-filter to protect the sensor from sediment and particles, especially in systems with potentially unclean water sources.
  • Calibration: While factory calibrated, for highly critical applications, consider performing your own calibration against a known flow standard to fine-tune accuracy.
  • Data Logging: Pair the sensor with a microcontroller (e.g., Arduino, Raspberry Pi) to log flow data over time, enabling analysis of water consumption or system performance.

9. Warranty and Support

For any technical assistance, warranty claims, or support inquiries regarding your DIGITEN FL-308D Water Flow Sensor, please contact the DIGITEN Official Store or your authorized reseller. Ensure you have your purchase details and model number available when contacting support.

© 2023 DIGITEN. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.