1. Introduction
The PowMr Hybrid Solar Inverter is a multi-functional inverter/charger, combining functions of an inverter, MPPT solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display allows user-configurable and easily accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
This inverter is designed for off-grid solar power systems, providing a pure sine wave output suitable for various electronic devices. It is available in 2KW (12V battery system) and 3.2KW (24V battery system) variants.
2. Important Safety Instructions
Please read all instructions and cautionary markings on the unit and its accessories before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Electrical Safety: All wiring must be performed by qualified personnel. Ensure proper grounding. Do not operate the inverter if it appears damaged.
- Battery Safety: Work with batteries carefully. Wear eye protection and protective clothing. Batteries can produce explosive gases. Do not smoke or allow sparks or flames near batteries.
- Ventilation: Install the inverter in a well-ventilated area to prevent overheating. Maintain adequate clearance around the unit for airflow.
- Environment: Avoid installing the inverter in direct sunlight, near heat sources, or in areas with excessive moisture, dust, or corrosive substances.
- Maintenance: Disconnect all power sources (AC, PV, Battery) before performing any maintenance or cleaning.
3. Product Features
- Pure sine wave inverter.
- Built-in MPPT solar charge controller with up to 140A maximum charge current.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Auto restart while AC is recovering.
- Overload, over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Optional WIFI/GPRS remote monitoring capability.

4. Package Contents
Upon unpacking, please ensure all items are included and undamaged:
- PowMr Hybrid Solar Inverter Unit
- User Manual
- (Potentially) Communication cables (e.g., USB, RS232, or WIFI module)
If any items are missing or damaged, please contact your vendor immediately.
5. Setup and Installation
5.1 Physical Installation
Choose a suitable location for the inverter. It should be:
- Mounted vertically on a wall or sturdy surface.
- Indoors, protected from direct sunlight, rain, and moisture.
- Well-ventilated, with at least 20 cm (8 inches) clearance on all sides for proper heat dissipation.
- Away from flammable materials and corrosive gases.
- Within the recommended operating temperature range of -10°C to 50°C.
5.2 Wiring Connections
All wiring must comply with local and national electrical codes. It is highly recommended that a qualified electrician performs the installation.

- Grounding: Connect the inverter's ground terminal to a reliable earth ground.
- Battery Connection: Connect the battery cables to the BATTERY terminals (+ and -) on the inverter. Ensure correct polarity. For 12V models, use a 12V battery bank; for 24V models, use a 24V battery bank.
- PV Input Connection: Connect the solar panel array to the PV IN terminals (+ and -). Ensure the PV input voltage (VOC) is within the 30V-150V range and does not exceed 150V.
- AC Input Connection: Connect the AC utility grid or generator to the AC IN (L and N) terminals.
- AC Output Connection: Connect your loads to the AC OUT (L and N) terminals.
- Communication Port (COMM): Connect optional communication devices (e.g., WIFI module) to this port for remote monitoring.
Caution: Double-check all connections for tightness and correct polarity before proceeding. Incorrect wiring can damage the inverter and connected equipment.
5.3 Initial Power-up Sequence
- Ensure all wiring is secure and correct.
- Turn on the battery breaker/switch.
- Turn on the PV array breaker/switch.
- Turn on the AC input breaker (if connecting to utility/generator).
- Turn on the inverter's power switch (located on the rear panel).
- Observe the LCD display for normal operation and any error messages.
6. Operating Instructions
6.1 LCD Display and Buttons
The inverter features an LCD display and four buttons for operation and configuration:
- ESC: Exit current menu or setting.
- UP: Scroll up through menu options or increase a setting value.
- DOWN: Scroll down through menu options or decrease a setting value.
- ENTER: Confirm selection or enter a submenu.
The LCD displays real-time system information such as battery voltage, PV input voltage, AC input/output voltage, load percentage, and operational status.
6.2 Configurable Settings
Use the buttons to navigate the LCD menu and adjust various parameters to suit your system requirements. Key configurable settings include:
- Output Source Priority: Set whether the inverter prioritizes solar, utility, or battery power for supplying loads.
- Charger Source Priority: Define whether solar or AC utility is the primary source for charging batteries.
- Battery Type: Select the type of battery connected (e.g., AGM, Flooded, Lithium) for optimal charging.
- Maximum Charging Current: Adjust the total charging current (AC + Solar) to protect your batteries.
- AC Input Voltage Range: Configure the acceptable AC input voltage range to protect sensitive loads or allow for wider utility fluctuations.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter, especially the ventilation openings, to prevent dust buildup. Use a dry cloth. Do not use liquid cleaners.
- Connection Checks: Annually inspect all wiring connections (battery, PV, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
- Environmental Check: Ensure the installation environment remains within specified temperature and humidity ranges.
- Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal conditions as per battery manufacturer guidelines.
8. Troubleshooting
If the inverter is not operating correctly, refer to the following common issues before contacting support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not turn on | Battery not connected or low voltage; Inverter switch off; Loose connections | Check battery connections and voltage; Turn on inverter switch; Tighten all connections |
| No AC output | Overload; Short circuit; Over temperature; Battery low | Reduce load; Check for short circuits; Allow inverter to cool; Charge battery |
| PV charging not working | PV panels not connected; Low PV voltage; PV polarity reversed | Check PV connections; Ensure PV voltage is within MPPT range (30-150V); Verify PV polarity |
| Error code on LCD | Specific system fault | Refer to the detailed error code section in the full manual (if available) or contact support. |
9. Specifications
| Feature | Specification |
|---|---|
| Model Name | POW-HVM2KW-12V / POW-HVM3.2KW-24V |
| Rated Power | 2000W (2KW model) / 3200W (3.2KW model) |
| Battery Voltage | 12VDC (2KW model) / 24VDC (3.2KW model) |
| AC Output Voltage | 220-240VAC |
| AC Output Frequency | 50Hz/60Hz (Auto sensing) |
| Max. PV Array Open Circuit Voltage (VOC) | 150VDC |
| MPPT Range @ Operating Voltage | 30 ~ 150VDC |
| Max. Solar Charging Current | 140A |
| Max. AC Charging Current | 80A |
| Operating Temperature | -10°C to 50°C |
| Weight | 7.5 KG |
| Certifications | CE, RoHS, FC |

10. User Tips
- Lithium Battery Compatibility: This inverter is compatible with lithium batteries. Ensure you select the correct battery type setting in the inverter's menu for optimal charging and discharge performance.
- Output Power Management: The inverter has a rated output power (2KW or 3.2KW). Avoid exceeding this rating to prevent overload protection shutdowns. If you need to limit power consumption, manage your connected loads accordingly.
- Remote Monitoring: Consider utilizing the optional WIFI/GPRS module for remote monitoring of your system's performance and status, which can be very convenient for off-grid setups.
11. Warranty and Support
The PowMr Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal operating conditions.
For technical support, warranty claims, or service inquiries, please contact your original point of purchase or the PowMr official support channels. Please have your product model and serial number ready when contacting support.