1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your SUGON 8620DX-PRO Hot Air Rework Station. Designed for precision work in mobile phone repair and general electronics, this station features high power, microcomputer temperature control, and a user-friendly interface. Please read this manual thoroughly before use to ensure optimal performance and safety.
2. Safety Precautions
WARNING: Failure to follow these safety instructions may result in electric shock, fire, or serious injury.
- Always follow the instructions in this manual. Do not use the de-soldering station for unspecified purposes.
- The air outlet and surrounding areas become extremely hot during operation. Exercise extreme caution to prevent burns.
- When not in use, ensure the handle is correctly placed on its designated rack. Never place it directly on the workbench or other surfaces. After use, allow the station to cool below 100°C (sleep mode) before turning off the power switch.
- Keep the air outlet clear of any obstructions.
- Do not place sharp objects on the air outlet hose, as this may cause damage.
- Maintain a minimum distance of 2mm between the air outlet and the target item during operation.
- Different wind nozzles may result in slightly different temperatures. Select the appropriate nozzle for your application.
- Unplug the power cord if the de-soldering station will not be used for an extended period.
- Handle the de-soldering station with care. Avoid tapping the handle or violently shaking the unit.
- Regularly inspect and maintain the station. Do not use it if it is damaged, especially if the power cable or air gun handle wire is compromised.
- Do not operate the station with wet hands or in wet conditions to prevent short circuits or electric shock.
- DO NOT use this station near flammable gases or other combustible substances. After use, ensure the station is cooled and stored away from such materials.
- Be aware that walls, ceilings, floors, and other surfaces may contain combustible materials. When working in such areas, continuously move the hot air de-soldering handle to prevent localized overheating, which could ignite materials.
- This product is not a toy. Keep out of reach of children. Do not allow children to operate or touch the station.
3. Key Features
- Four Working Channels: CH1, CH2, CH3, and CH4 allow for quick switching between preset air volume and temperature settings. Each channel's settings can be customized and stored.
- Digital Display: Clear display of set temperature, real-time temperature, and air volume for precise adjustments.
- Magnetic Switch Control: The handle automatically enters sleep mode when placed on its rack, facilitating real-time operation and energy saving.
- Automatic Sleep Function: Parameters can be set even when the unit is in sleep mode.
- Brushless Eddy Current Fan: Provides a wide range of adjustable air volume (1-200 levels) suitable for various applications.
- Rapid Heating: Achieves target temperature quickly (approx. 3 seconds) with stable and precise temperature control, unaffected by air volume.
- Automatic Cooling: Features a large air volume cooling function to extend the lifespan of the heating element and protect the hot air handle.
- Temperature Self-Calibration: Allows users to calibrate the temperature for accuracy.
- Multiple Protection Functions: Ensures safe and reliable operation.
4. Component Overview
Familiarize yourself with the main components and controls of your SUGON 8620DX-PRO rework station:


5. Setup and Initial Use
5.1. Nozzle Installation and Disassembly
The wind nozzle can be customized. Always ensure the station is cool and powered off before changing nozzles.
- Installation: Align the selected air nozzle with the air outlet steel pipe of the handle. Use the air nozzle puller on the side of the machine to align and press the nozzle into place. You should hear a "snap" sound when it's securely fastened. Verify the nozzle is clamped tightly before use.
- Disassembly: Remove the air gun handle from its stand. There is a clamping slot between the steel pipes of the wind mouth. Place the handle through this slot onto the air nozzle removal plate (located at the bottom of the handle frame). Hold the handle frame with one hand and gently pull the handle back to remove the nozzle. Alternatively, insert the handle with the nozzle into an empty position of the air nozzle puller, move it to the right to block the U-shaped card slot, and then pull up the handle by hand to extract the air nozzle.
Note: Allow the nozzle to cool down completely before attempting to change it to prevent burns.
5.2. Initial Power On
- Place the desoldering station on a flat, stable workbench.
- Connect the power cord securely to the station and a suitable power outlet.
- Turn on the power switch.
- Remove the hot air gun handle from its holder. The system will enter normal operating mode, and the temperature display will show "SETTING/TEMP" and "ACTUAL/TEMP".
6. Operation
6.1. Temperature and Air Volume Settings
- Temperature Adjustment:
- To increase temperature: Press the "TEMP ▲" button once to increase by 1°C. Press and hold for rapid increase.
- To decrease temperature: Press the "TEMP ▼" button once to decrease by 1°C. Press and hold for rapid decrease.
- Air Volume Adjustment:
- To increase air volume: Press the "AIR ▲" button once to increase by 1 level. Press and hold for rapid increase.
- To decrease air volume: Press the "AIR ▼" button once to decrease by 1 level. Press and hold for rapid decrease.
6.2. Channel Memory (CH1-CH4)
The station features four memory channels (CH1, CH2, CH3, CH4) to store your preferred temperature and air volume settings for different tasks.
- Saving Settings: After adjusting the temperature and air volume to your desired values, press and hold the corresponding channel button (e.g., "CH1") for a few seconds until the settings are saved.
- Recalling Settings: To recall saved settings, simply press the desired channel button (e.g., "CH1") once. The station will automatically adjust to the stored parameters.
6.3. Sleep Mode and Power Off
- Entering Sleep Mode: When the hot air gun handle is placed back into its holder, the system automatically initiates a large air volume cooling process. Once the actual temperature drops below 100°C, the station enters sleep mode. The display will show "Temperature drop" followed by "---".
- Waking from Sleep: To wake the station, simply lift the hot air gun handle from its holder.
- Power Off: For extended periods of non-use, always turn off the main power switch.
Tip: For optimal heating element lifespan and IC chip safety, use the lowest effective temperature and highest practical air volume for your task.
6.4. Additional Functions
- Temperature Unit Conversion: Double-press the "SET" (multifunction) button to switch between Celsius (°C) and Fahrenheit (°F).
- Buzzer Setting: Press and hold the "SET" (multifunction) button for two seconds to toggle the buzzer sound on or off.
- Temperature Calibration: With the unit powered off, press and hold the "SET" (multifunction) button for two seconds, then turn on the power switch. This enters the temperature calibration interface. Use the "AIR +/-" buttons to adjust the correction temperature. Press the "SET" button again to exit calibration and return to normal operation.
7. Maintenance
7.1. Replacing the Heating Element
WARNING: Always ensure the station is cool and powered off before replacing the heating element to prevent burns and electric shock.

- Loosen the handle anti-scalding sheath on the hot air gun handle and remove it.
- Unscrew the three screws that secure the steel pipe (which contains the heater element).
- Carefully remove the old heating element.
- Install the new heating element and reassemble the handle by reversing the steps.
Note: The steel pipe of this product may show slight yellowing after prolonged use at 500°C. This is a normal aging phenomenon and does not affect performance.
7.2. Regular Checks
- Regularly inspect the power cable and hot air gun handle wire for any signs of damage. Do not use the station if any damage is found.
- Keep the air outlet and nozzles clean to ensure optimal airflow.
8. Troubleshooting
The station's display may show specific codes to indicate potential issues:
- "HEA" Displayed: Indicates a problem with the heating element of the de-soldering station. Inspect the heating body and related components.
- "TMP" Displayed: Indicates a problem with the sensor part of the de-soldering station. Inspect the sensor and related components.
- "FAN" Displayed: Indicates a fault with the fan. Inspect the fan and related components.
If you encounter any of these error codes or other issues, please contact customer support for assistance.
9. Specifications
| Feature | Specification |
|---|---|
| Model Number | 8620DX-PRO |
| Power (8620DX-PRO) | 1300W |
| Power (8610DX) | 1000W |
| Power Supply | AC220V 50Hz/60Hz, AC110V 50Hz/60Hz |
| Temperature Range | 100°C - 500°C (212°F - 932°F) |
| Air Volume Level (8620DX-PRO) | 1-200 levels |
| Air Volume Level (8610DX) | 1-120 levels |
| Overall Dimensions (L*D*H) | 188mm × 245mm × 135mm |
| Net Weight | 5.5 KG |
| Gross Weight | 6.6 KG |
| Origin | Mainland China |
| Certification | CE |
| Temperature Control Type | Microcomputer |
| Application | Mobile Phone Repair, Electronics Rework |
10. User Tips
- Nozzle Selection: Always choose the correct nozzle size for the component you are working on. Smaller nozzles provide more concentrated heat, while larger ones distribute heat over a wider area.
- Preheating: For sensitive components or larger boards, consider preheating the PCB to reduce thermal stress and improve soldering/desoldering results.
- Cleaning: Keep your nozzles and the hot air gun clean. Residue can affect airflow and heating efficiency.
- Practice: If you are new to hot air rework, practice on scrap boards to get a feel for temperature and airflow settings before working on critical components.
11. Warranty and Support
Specific warranty details for this product are not provided in this manual. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer's authorized service center. Always provide your product model number (8620DX-PRO) and purchase date when seeking support.