1. Introduction
The GVDA Digital Clamp Meter represents a new generation of high-performance, intelligent digital clamp meters. Designed for ease of use, efficiency, and safety, this device combines a wide range of functions to assist professionals and enthusiasts in various electrical measurements. It is capable of measuring AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, capacitance, temperature, diode, continuity, Non-Contact Voltage (NCV), and live wire detection.
This manual provides essential information for the safe and effective operation of your GVDA Digital Clamp Meter. Please read it thoroughly before use and keep it for future reference.
2. Safety Information
Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, and personal injury. Failure to follow these safety rules may result in severe injury or death.
- Ensure the meter is in good working condition before use.
- Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Always disconnect power to the circuit under test before making resistance, capacitance, or diode measurements.
- Do not operate the meter with the battery cover removed or loosened.
- Replace the battery as soon as the low battery indicator appears to ensure accurate readings.
- Do not use the meter if it appears damaged or if the insulation on the test leads is compromised.
- Always use the correct function and range for the measurement.
- Keep fingers behind the finger guards on the test probes during use.
3. Product Overview
The GVDA Digital Clamp Meter is designed with user-friendly controls and a clear display for efficient operation. Below is a diagram illustrating the main components of the device:

Key Components:
- NCV Probe: Used for non-contact voltage detection.
- Clamp: Opens to enclose a conductor for current measurement.
- Flashlight: Illuminates the work area.
- Trigger: Opens the clamp jaw.
- Power Button: Turns the device on/off.
- FUNC / AUTO Button: Switches between functions or activates Smart (AUTO) mode.
- MAX / MIN Button: Records maximum and minimum values.
- SEL / INRUSH Button: Selects measurement modes or activates Inrush Current measurement.
- Display: High-definition color LCD showing measurement readings and unit symbols.
- Black Meter Pen Socket: Connection point for the black test lead.
- Red Meter Pen Socket: Connection point for the red test lead.
- Alarm Indicator LED: Provides visual alerts during NCV and live wire detection.
- Data Hold / Flashlight Button: Freezes the current reading on the display or activates the flashlight.

4. Setup
4.1. Battery Installation
The GVDA Clamp Meter requires 3 x 1.5V AAA batteries (not included) for operation. To install or replace batteries:
- Ensure the device is powered off.
- Locate the battery compartment cover on the back of the meter.
- Use a screwdriver to open the battery cover.
- Insert three AAA batteries, observing the correct polarity (+/-).
- Replace the battery cover and secure it with the screw.

4.2. Test Lead Connection
For measurements requiring test leads (voltage, resistance, capacitance, diode, continuity, temperature), connect the red test lead to the 'INPUT' terminal and the black test lead to the 'COM' terminal.
The clamp meter features a convenient design for storing one test lead while using the other for single-probe measurements.

5. Operating Instructions
The GVDA Clamp Meter offers various measurement modes. Always select the appropriate mode for your task.
5.1. Power On/Off
Press the Power Button to turn the meter on. The display will show "CAL" during self-calibration, then switch to "Auto" mode. Press and hold the Power Button again to turn it off. The meter also features an auto power-off function to conserve battery life.
5.2. Smart (AUTO) Measurement
By default, the meter enters Smart (AUTO) mode upon power-on. In this mode, it automatically identifies and measures voltage, resistance, and continuity when test leads are connected. Current is measured using the clamp.

5.3. AC/DC Current Measurement
To measure AC or DC current (GD166B and GD168B models only for DC current):
- Select the current measurement function using the FUNC / AUTO or SEL / INRUSH button if not in auto mode.
- Press the Trigger to open the clamp.
- Enclose a single conductor with the clamp. Ensure only one wire is clamped for accurate readings.
- Slowly release the trigger until the clamp is completely closed.
- Read the current value on the display.


5.4. AC/DC Voltage Measurement
To measure AC or DC voltage:
- Connect the test leads to the appropriate terminals.
- Select AC or DC voltage mode using the FUNC / AUTO button.
- Touch the test probes to the points where voltage needs to be measured.
- Read the voltage value on the display.
5.5. Resistance, Capacitance, Diode, Continuity
To measure resistance, capacitance, test diodes, or check continuity:
- Connect the test leads.
- Use the FUNC / AUTO button to cycle through these modes.
- Apply the test probes to the component or circuit.
- Read the measurement or observe the continuity buzzer/diode drop.

5.6. NCV (Non-Contact Voltage) Measurement
To detect AC voltage without contact:
- Select NCV mode using the FUNC / AUTO button.
- Bring the NCV probe close to the conductor.
- The meter will indicate the presence of AC voltage with an audible beep and LED light. A slow beep and green LED indicate a weak field ("--L"), while a fast beep and red LED indicate a strong field ("--H").

5.7. Live Wire Detection
To detect live wires:
- Select Live mode using the FUNC / AUTO button.
- Touch the red test probe to the suspected live wire.
- The meter will indicate a live wire with an audible beep and LED light. A low beep and green LED indicate low voltage ("--L"), while a fast beep and red LED indicate high voltage ("--H").

5.8. Temperature Measurement
To measure temperature:
- Connect the thermocouple probe to the meter's input terminals.
- Select temperature mode using the FUNC / AUTO button.
- Place the thermocouple probe into the object or environment to be measured.
- Read the temperature value on the display in Celsius or Fahrenheit.

5.9. Flashlight
Press and hold the Data Hold / Flashlight Button for more than 2 seconds to turn the flashlight on or off. This feature is useful for working in dimly lit conditions.

6. Maintenance
- Cleaning: Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
- Storage: If the meter is not used for a long period, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- Calibration: The meter is factory calibrated. For professional use, periodic calibration by a qualified service center is recommended to maintain accuracy.
7. Troubleshooting
- No Display/Power On: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- "OL" Indication: This indicates an over-range condition. The measured value exceeds the selected range. Switch to a higher range or ensure the measurement is within the meter's capabilities.
- Inaccurate Readings: Ensure test leads are properly connected and not damaged. Verify the correct measurement function is selected. Check for external interference.
- Low Battery Indicator: Replace batteries immediately to ensure accurate measurements and proper operation.
8. Specifications
The GVDA Digital Clamp Meter comes in three models: GD166A, GD166B, and GD168B. Key differences include DC current measurement capability and specific features.

| Function | Range | Accuracy (GD166A) | Accuracy (GD166B) | Accuracy (GD168B) |
|---|---|---|---|---|
| DC Voltage | 600mV/6V/60V/600V | ±(0.5%+5) | ±(0.5%+5) | ±(0.5%+5) |
| AC Voltage | 600mV/6V/60V/600V | ±(0.8%+5) | ±(0.8%+5) | ±(0.8%+5) |
| DC Current | 60A/600A | ±(2.5%+5) | ±(2.5%+5) | |
| AC Current | 60A/600A | ±(2.5%+5) | ±(2.5%+5) | ±(2.5%+5) |
| Resistance | 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ | ±(1.0%+5) | ±(1.0%+5) | ±(1.0%+5) |
| Capacitance | 6nF/60nF/600nF/6µF/60µF/600µF/6mF/60mF | ±(4.0%+5) | ±(4.0%+5) | ±(4.0%+5) |
| Frequency | 100Hz/1kHz/10kHz/100kHz/1000kHz/10MHz | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
| Duty | 1%~99% | ±(3.0%+3) | ±(3.0%+3) | ±(3.0%+3) |
| Temperature | -40°C~1000°C / -40°F~1832°F | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
| Continuity | 600Ω | ✔ | ✔ | ✔ |
| Diode | ✔ | ✔ | ✔ | |
| NCV | ✔ | ✔ | ✔ | |
| Live | ✔ | ✔ | ✔ | |
| Counts | 6000 | 6000 | 6000 | 6000 |
| Analog bar | ✔ | ✔ | ||
| Data hold | ✔ | ✔ | ✔ | |
| Max/Min | ✔ | ✔ | ✔ | |
| Backlight | ✔ | ✔ | ✔ | |
| Flashlight | ✔ | ✔ | ✔ | |
| DCA ZERO | ✔ | ✔ | ||
| SMART FUNCTION (AUTO) | ✔ | ✔ | ✔ | |
| Low battery indication | ✔ | ✔ | ✔ | |
| Auto power off | ✔ | ✔ | ✔ | |
| True RMS | ✔ | ✔ | ✔ | |
| Power | 3xAAA (1.5V) batteries (not include) | |||
| Safety Rating | EN61010-1 CAT III 600V |



General Specifications:
- Display: 6000 Counts HD Colour LCD Display
- Over Range Indication: “OL”
- Input Polarity Indication: Displays “-” for negative input
- Low Battery Indication: Yes
- Auto Power Off: Yes
- True RMS: Yes
- Clamp Opening Size: 36mm
- Product Size: 199mm x 81mm x 32mm (GD166A/GD166B), 199mm x 76mm x 32mm (GD168B)
- Package Weight: Approximately 440g
- Safety Rating: EN61010-1 CAT III 600V
9. User Tips
- Model Differences: Be aware that model GD166A is an AC Clamp Meter and does not include DC current measurement. Models GD166B and GD168B are AC/DC Clamp Meters and can measure both AC and DC current. Always refer to the specifications for your specific model.
- Single Conductor for Current: When measuring AC or DC current with the clamp, ensure you only enclose a single live or neutral wire. Clamping two wires (e.g., live and neutral together) will result in a zero reading as the currents cancel each other out.
- Test Lead Care: Always store test leads properly to prevent damage to the insulation. Damaged leads can pose a safety hazard and affect measurement accuracy.
- Smart Mode Convenience: The Smart (AUTO) mode is excellent for general troubleshooting as it automatically detects the measurement type (voltage, resistance, continuity) when using test leads, simplifying operation.
10. Warranty and Support
This product comes with a manufacturer's limited warranty covering defects in materials and workmanship. Please refer to your purchase documentation for specific warranty terms and duration. For technical support, service, or warranty claims, please contact the seller or manufacturer directly.