1. Introduction
The SALORIE Electric Cupping Massager is an intelligent negative pressure device designed for cupping, scraping (Gua Sha), and massage therapy. It combines adjustable suction, constant temperature heating, and red light microelectronics to provide deep physiotherapy and acupoint stimulation. This manual provides essential information for the safe and effective operation and maintenance of your device.

2. Product Features
- Intelligent Negative Pressure Cupping: Provides adjustable suction for effective cupping therapy.
- Scraping (Gua Sha) Function: Designed for traditional scraping therapy to promote circulation.
- Constant Temperature Heating: Offers 45-50℃ hot compress for warming and comfort.
- Red Light Microelectronics: Utilizes pulsed electrical frequency for relaxation and nerve stimulation.
- One-Key Pressure Relief: Ensures painless and comfortable removal of the device after cupping.
- 12 Adjustable Levels: Both suction strength and heating intensity can be adjusted across 12 levels.
- Automatic Shutdown: Device automatically turns off after 20 minutes of continuous use for safety and battery conservation.
- Durable Battery Life: Designed for extended use with power failure protection.
- Models:
- DS-A15: Features stainless steel ball heating.
- DS-A12: Features infrared heating.

3. Package Contents
Upon opening the package, please ensure all items are present and in good condition:
- 1x Electric Cupping Device
- 5x Filter Sponges
- 1x USB Charging Cable (Type-C)
- 1x English User Manual (this document)

4. Setup
4.1 Charging the Device
- Locate the Type-C charging port on the top of the device.
- Connect the provided USB charging cable to the device and a suitable USB power adapter (not included).
- The LED display will indicate charging status. Ensure the device is fully charged before first use.

4.2 Inserting the Filter Sponge
- Ensure the device is turned off.
- Locate the central opening at the bottom of the device.
- Insert one of the provided filter sponges into this opening. The filter sponge helps prevent clogging and ensures continuous suction.

5. Operating Instructions
5.1 Power On/Off
- Press and hold the Power button (usually marked with a circle and a line) for a few seconds to turn the device on or off. The LED display will light up when powered on.
5.2 Adjusting Suction Strength
- Once powered on, press the '+' or '-' buttons to adjust the suction strength. There are 12 levels of suction.
- For scraping, it is recommended to start with the 1st gear suction.
5.3 Adjusting Heating Intensity
- Press the heating button (often marked with wavy lines or 'SSS') to activate the heating function.
- Use the '+' or '-' buttons to adjust the heating intensity across 12 levels. The device provides a constant temperature of 45-50℃.

5.4 Cupping Therapy
- Apply a small amount of essential oil or massage cream to the skin area where you intend to perform cupping.
- Place the device firmly on the skin. The suction will begin.
- Adjust the suction level as desired.
- To release the device, press the one-key pressure relief button (often marked with a wave or similar symbol). This ensures painless removal.

5.5 Scraping (Gua Sha) Therapy
- Apply essential oils to the skin area.
- Set the suction to the 1st gear.
- Move the massager quickly and continuously across the skin. Avoid leaving it in one spot for too long to prevent excessive suction marks.
- The device features eight steel ball heads (for DS-A15) for smooth rolling during scraping.

5.6 Red Light Microelectronics
- The device incorporates red light microelectronics that transmit pulsed electrical frequencies to the skin, aiding in relaxation. This function operates automatically when the device is in use.

5.7 Automatic Shutdown
- The device is equipped with a 20-minute automatic shutdown feature to prevent overuse and conserve battery.
5.8 Video Demonstration
6. Safety Precautions
- Scraping Treatment Time: The first scraping treatment should be shortened. For individuals who are weak, the scraping time should be less than 20 minutes.
- Optimal Scraping Duration: The best scraping time for each body part is 3 to 5 minutes.
- Interval Between Treatments: Allow 5 to 7 days between two scraping treatments on the same body part.
- Hydration: Drink a cup of hot (warm) boiled water after scraping to replenish body fluids and promote metabolism.
- Avoid Cold Water: Do not touch cold water for 24 hours after scraping.
- Bathing After Scraping: Wait 1 to 6 hours after scraping before bathing, depending on the severity of the marks:
- Mild scraping marks: Wait 1 hour.
- Moderate scraping marks: Wait 3 hours.
- Severe scraping marks: Wait more than 6 hours.
- Contraindications: The device should NOT be used by individuals who are critically ill, pregnant, have skin diseases, or are extremely full or hungry.
7. Maintenance
7.1 Cleaning the Device
- After each use, ensure the device is turned off and unplugged.
- Wipe the contact surface and the body of the device with a soft, damp cloth.
- Do not immerse the device in water or use harsh chemicals for cleaning.
7.2 Replacing Filter Sponges
- The filter sponge should be regularly checked and replaced when it appears dirty or worn to maintain optimal suction and hygiene.
- Gently remove the old sponge and insert a new one as described in Section 4.2.
8. Troubleshooting
- Device not turning on: Ensure the device is fully charged. If not, connect it to the charger.
- Weak or no suction: Check if the filter sponge is correctly inserted and clean. Ensure the device makes full contact with the skin. Adjust the suction level using the '+' button.
- Device stops unexpectedly: The device has a 20-minute automatic shutdown feature. If it stops before 20 minutes, check the battery level.
- Scraping marks are too strong: Reduce the suction level and move the device faster across the skin. Remember that marks are normal and typically fade within 5-7 days.
- Device feels too hot: Adjust the heating intensity using the '-' button. The device is designed for a constant temperature of 45-50℃.
9. Specifications
| Parameter | Value |
|---|---|
| Product Colors | Dark Green, White, Black |
| Net Weight | Approx. 300g |
| Rated Voltage | 5V |
| Rated Power | 8W |
| Product Size (L x W x H) | 200mm x 90mm x 90mm (7.9in x 3.5in x 3.5in) |
| Suction Range | 0-120 kPa |
| Heating Temperature | 45-50℃ (Constant Temperature) |
| Automatic Shutdown | 20 minutes |
| Operation Type | Electric-operated |
| Applicable People | Everyone (excluding contraindications) |

10. User Tips
- Pre-warm the skin: For better results and comfort, consider applying a warm towel to the area before using the massager.
- Use essential oils: Always use essential oils or massage cream to ensure smooth gliding during scraping and to enhance the cupping effect.
- Start low, go slow: Begin with the lowest suction and heating levels and gradually increase them to find what is comfortable and effective for you.
- Stay hydrated: Drinking water before and after your session can help with detoxification and overall well-being.
- Listen to your body: If you experience any discomfort or pain, reduce the intensity or stop using the device immediately.
11. Warranty and Support
For warranty information, returns, or technical support, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.