KeepLiNK 9-Port Multi-Gigabit Managed Ethernet Switch

Model: KP-9000-9XHML-X

Brand: keepLiNK

1. Introduction

The KeepLiNK KP-9000-9XHML-X is a 9-port Multi-Gigabit managed Ethernet switch designed to cost-effectively expand networks with high-speed capabilities. It features eight (8) 2.5G RJ45 ports and one (1) 10G SFP+ uplink port, housed in a durable metal case. This switch supports flexible deployment options, including desktop or wall mounting. Engineered for energy efficiency and silent operation, it provides reliable performance for various network environments. Advanced features like 802.1p traffic prioritization and jumbo frame support ensure seamless integration into complex network infrastructures.

Video: Overview of the KeepLiNK 9-Port Multi-Gigabit Managed Ethernet Switch.

2. Packing List

Please verify that all items are present in your package:

  • Device (KeepLiNK KP-9000-9XHML-X Switch)
  • AC power cord (provided for built-in power supply device)
  • Power adapter (provided for non built-in power devices)
  • Hanging ears and screws (provided for rack mounted device)
  • User manual
  • Certificate of conformity

3. Specifications

FeatureDescription
Model NumberKP-9000-9XHML-X
Brand NamekeepLiNK
Number of Interfaces10 (8 x 2.5Gb RJ45, 1 x 10Gb SFP+ Uplink)
Transmission Rate10000 Mbps (10Gbps)
Switch Capacity60Gbps
Communication ModeFull-Duplex & Half-Duplex
FunctionSNMP, VLAN Support, WEB Management, LACP, Flow Control, STP/RSTP, QoS
VLAN SupportYes
CertificationCE, FCC, RoHS
Dimensions (H x W x D)175 x 73 x 28 mm
Power InputDC 12V
OperationFan-less, Silent Operation
Energy EfficiencyEnergy Efficient Ethernet (IEEE802.3az)
Mounting OptionsDesktop, Wall Mount, Rack Mount
Key Features of KeepLiNK switch including port types, management, operation, mounting, and dimensions.

Image: Key Features and dimensions of the switch.

Rear view of the KeepLiNK switch showing the DC 12V power input.

Image: Rear view of the switch with DC 12V power input.

4. Safety Precautions

4.1 Precautions for Device Connection and Installation

  • Network Cable:
    • For 100Mbps RJ45 interfaces, use Cat5 or above Ethernet cable.
    • For 1000Mbps/2.5GE/5GE RJ45 interfaces, use Cat5e or above Ethernet cables.
    • For 10GE speed RJ45 interfaces, use Cat6a or above Ethernet cables.
  • Fiber Optic Cable:
    • Fiber optics and connectors must be used in conjunction with optical modules.
    • The bending radius of the optical fiber should not be less than 40mm.

4.2 Safety Precautions for Equipment Installation

  • Always ensure the power is OFF during installation.
  • The switch requires the correct power supply to function normally. Verify that the power supply voltage matches the voltage indicated on the switch.
  • Before powering on, ensure the power circuit is not overloaded to prevent operational issues or damage.
  • To avoid electric shock, do not open the casing of the switch while it is in operation, even if it appears inactive. Do not attempt to open it yourself.

4.3 Precautions for Equipment Installation Environment

  • Maintain a stable temperature and humidity to ensure long-term stable operation and extend service life. Extreme conditions can cause insulation material leakage, deformation, and metal corrosion.
  • To prevent static electricity from affecting operation, regularly remove dust, maintain clean indoor air, ensure proper grounding, and facilitate smooth static electricity transfer.
  • To minimize electromagnetic interference, ensure the power supply system has anti-grid interference measures. Keep switches away from high-frequency, high-power, and high-current equipment.
  • For lightning protection, ensure the rack, power sockets, and ground are in good contact. Wiring should be reasonable to avoid internal induced lightning. For outdoor wiring, signal lightning protectors are recommended.

5. Installation

The switch supports multiple installation methods. Choose the method that best suits your environment.

5.1 Rack Mounted Installation

  1. Prepare the hanging ears and screws.
  2. Secure the hanging ears to both ends of the device using the provided screws.
  3. Push the device parallel to the tray into the cabinet.
  4. Secure the device to the cabinet using cabinet screws.

5.2 Desktop Installation

  • Place the switch on a flat and secure desktop surface.
  • Ensure the work environment provides sufficient ventilation and heat dissipation space around the device.
  • Attention: Do not place heavy objects on top of the switch.

5.3 Wall Mounting Installation

  1. Fix screws onto the wall according to the position of the wall mounting holes on the switch. Ensure a distance of 3mm ± 0.5mm between the screw nuts and the wall.
  2. Align the wall mounting holes on the device with the fixed screws for installation and secure fixation.

6. Operating Instructions

6.1 Product Indicator Lights

The indicator lights provide visual feedback on the switch's status and port activity.

SignDefinitionStatusDescription
PWR/PPower indicator lightGreen light always on/offPower is connected/not connected
AI PoEAI lightGreen light on/offAI PoE started/not started
SYS/NMS/S/NSystem lightGreen light on/offSystem working/system not started
100Mbps copper port Connection status indicator lightLeft light SpeedYellow light always on
Yellow light off
100M speed
10M speed
Right light Link/actGreen light always on
Green light off
Green light blink
Port connected
Port not connected
The port is connected and there is data transmission and reception
1000Mbps copper port Connection status indicator lightLeft light SpeedYellow light always on
Yellow light off
1000M speed
10/100M speed
Right light Link/actGreen light always on
Green light off
Green light blink
Port connected
Port not connected
The port is connected and there is data transmission and reception
2.5G copper port Connection status indicator lightLeft light SpeedYellow light on
Yellow light off or green light always on
2.5G speed
10/100/1000M speed
Right light Link/actGreen light always on
Green light off
Light blink
Port connected or 10/100/1000M speed
Port not connected
The port is connected and there is data transmission and reception
10G copper port Connection status indicator lightLeft light SpeedYellow light on
Green light on
Light blink
10G speed
5G speed
Data transmission and reception
Right light SpeedYellow light on
Green light on
Light off
Light blink
2.5G rate
1G rate
Port not connected
The port is connected and there is data transmission and reception
10G downlink fiber port Connection status indicator lightLink/actYellow light always on
Green light always on
Light off
Light blink
10G speed
1G rate
Port not connected
The port is connected and there is data transmission and reception
Optical port connection status indicator lightLink/actGreen light on
Green light off
Port connected
Port not connected

Note: The specific indicator lights are subject to the actual product.

Front view of the KeepLiNK 2.5Gb Managed Switch showing all ports and indicator LEDs.

Image: Front panel with ports and indicator lights.

6.2 DIP Switch Instructions

The DIP switches allow for quick configuration of certain features. The specific definitions may vary slightly based on the product version.

DIP Switch Definition for Non-PoE Switches

DIP switch specificationSequenceDefinition of DIP switchDescription
4 DIP Switch1ReserveReserve
2Extend250m long distance transmission (downlink port)
3Port IsolationPort isolation
4Storm ControlSuppress broadcast data

DIP Switch Definition for PoE Switches

DIP switch specificationSequenceDefinition of DIP switchDescription
4 DIP Switch1AI PoEAuto detect and reboot unresponsive PoE devices for recovery
2Extend250m long distance transmission (PoE port)
3Port IsolationPort isolation
4Storm ControlSuppress broadcast data
3 DIP Switch1Extend250m long distance transmission (PoE port)
2StandardNormal mode
3Port IsolationPort isolation
2 DIP Switch1Extend250m long distance transmission (PoE port)
2AI PoE/ReserveAI PoE/Reserve

6.3 WEB Management

This section applies to network management products. For first-time use:

  1. Connect the switch to your PC and ensure the device initialization is complete.
  2. Configure your PC's IP address to be in the same network segment as the switch's default IP address.
  3. Open a web browser on your PC and input http://192.168.1.168 in the address bar. Press Enter.
  4. At the network management login interface, enter the default username "admin" and password "admin" to log in.
Screenshot of the web management login interface for the switch.

Image: Web Management Login Interface.

6.4 Console Port Management

  1. Use a console port cable to connect the console port of your PC to the switch.
  2. Open terminal simulation software (e.g., PuTTY, Tera Term).
  3. Establish a connection, select the appropriate serial port, and configure the communication parameters as follows:
    • Transmission rate: 115200
    • Data bit: 8
    • Check digit: None
    • Stop bit: 1
    • Flow control method: None

6.5 PoE Powered Function (if applicable)

This feature is applicable to PoE switches only. Standard PoE power supply includes:

  • Protocol detection
  • Power pin sequence detection
  • Power output management
  • Anomaly protection
  • Link anomaly monitoring

The PoE power supply protocols supported are:

  • IEEE802.3af (15.4W)
  • IEEE802.3at (30W)
  • IEEE802.3bt (90W)

Standard PoE power supply pin sequences:

  • Standard PoE: 1,2+/3,6-
  • PoE++: 1,2,4,5+/3,6,7,8-

Standard PoE switches automatically detect and provide power to standard PoE devices. Non-PoE devices will not receive power but will still transmit data.

Diagram illustrating PoE power and data pins on an Ethernet port.

Image: PoE Power and Data Pin Diagram.

7. Maintenance

  • Cleaning: Regularly clean the exterior of the switch with a soft, dry cloth. Avoid using liquid or aerosol cleaners.
  • Ventilation: Ensure that the ventilation openings on the switch are not blocked to prevent overheating. Maintain adequate airflow around the device.
  • Power Supply: Use only the provided power adapter. Disconnect the power supply during electrical storms or when unused for long periods.
  • Cable Management: Keep network cables organized and free from kinks or excessive bending to maintain optimal performance and prevent damage.
  • Firmware Updates: Check the manufacturer's website periodically for firmware updates to ensure optimal performance, security, and access to new features.

8. Troubleshooting

  • No Power: Check if the power adapter is securely connected to both the switch and a working power outlet. Verify the power indicator light (PWR/P) is on.
  • No Link/Activity on Port: Ensure the Ethernet cable is properly connected to both the switch port and the connected device. Check the Link/Act LED for activity. Try a different cable or port.
  • Slow Network Speed: Verify that connected devices are operating at their expected speeds (e.g., 2.5G, 1G). Check cable types (Cat5e/Cat6a for higher speeds). Ensure there are no broadcast storms (check DIP switch settings if applicable).
  • Cannot Access Web Management: Confirm your PC's IP address is in the same subnet as the switch's default IP (192.168.1.168). Double-check the URL and login credentials (default: admin/admin).
  • PoE Device Not Powering On: Ensure the connected device is PoE compatible and meets the power requirements. Check the AI PoE light if applicable. Verify the PoE switch's DIP settings for PoE functionality.
  • Intermittent Connectivity: Check for loose cable connections. Ensure the switch is in a stable environment, free from excessive heat or electromagnetic interference.
  • Switch Unresponsive: Try power cycling the switch (disconnect power, wait 10 seconds, reconnect). If issues persist, perform a factory reset (refer to the manual for specific instructions, usually involving a reset button).

9. User Tips

  • Performance Verification: Use tools like iperf3 to test the actual throughput of your RJ45 ports and confirm multi-gigabit speeds.
  • Managed Features: Leverage the web management interface for advanced configurations like VLANs, LACP, and QoS to optimize your network. The VLAN configuration is similar to other common brands like TP-Link.
  • Plug and Play: For basic network expansion, the switch can often be used immediately without complex settings, especially if your network uses the default IP range.
  • Power Cycling: Avoid rapid power cycling of the device, as this may stress internal components.
  • VLAN Management: Be aware that VLAN management might be limited to VLAN 1, which could be a consideration for complex network segmentation.
  • Firmware: Note the firmware version and date (e.g., V100.9.9.1.7, June 7 2025) for future reference and updates.

10. Warranty and Support

10.1 After-sales Service Letter of Commitment

  • Within 7 Days of Sale: If the entire device fails, you may choose to repair, replace, or return it.
  • Within 7 Days to 1 Year of Sale: If a performance failure occurs, the entire machine can be repaired or replaced. This is based on the purchase invoice and proof of three guarantees (repair, replacement, refund).
  • Beyond 1 Year: After the one-year hardware warranty period, the cost of replacing hardware will be borne by the user. No additional costs will be added by our company.

10.2 Circumstances Without Warranty

The warranty does not cover equipment failure or damage under the following conditions:

  • Accessories supplied by other companies (e.g., power supply, adapter) are covered by their respective manufacturers' warranties.
  • The whole machine or parts have exceeded their warranty period.
  • Equipment failure or damage caused by unauthorized repair, alteration, or demolition by personnel not affiliated with our company.
  • Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, and inputting inappropriate voltage.
  • Failure or damage caused by the use of non-genuine or unpublished software.
  • Failures or losses caused by natural disasters (e.g., earthquakes, fires).

10.3 Other Service Commitments

  • We provide 24-hour after-sales support services.

11. Additional Resources

For a detailed user manual in PDF format, please refer to the official document: User manual (PDF).

© 2024 KeepLiNK. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.