REX PH100B

Contents

PH100B Digital PH Meter Instruction Manual

Model: PH100B

1. Introduction

This manual provides detailed instructions for the proper use and maintenance of the REX PH100B Digital PH Meter. The PH100B is a high-precision benchtop tester designed for accurate pH and mV measurements, featuring automatic calibration, 0.01 pH resolution, and an IP54 waterproof rating, making it suitable for various applications including hydroponics.

2. Safety Information

  • Always handle the pH electrode with care. The glass bulb is fragile.
  • Avoid direct contact with calibration buffers and samples, especially if they are corrosive or hazardous. Use appropriate personal protective equipment.
  • Ensure the power adapter is connected to a suitable power source (100-240V AC).
  • Do not immerse the meter unit in water, despite its IP54 rating, which indicates splash resistance, not full waterproofing.
  • Keep the device away from strong electromagnetic fields to prevent interference with readings.

3. Package Contents

Upon unpacking, please verify that all components are present:

  • PH100B Digital PH Meter Unit
  • pH Electrode (BNC connector)
  • Electrode Stand
  • AC Power Adapter (DC9V output)
  • User Manual (this document)

4. Product Overview

The PH100B meter features a large LCD display and intuitive controls for ease of use. Key components include:

PH100B Digital PH Meter with electrode and stand
Figure 1: PH100B Digital PH Meter with electrode and stand. The meter unit displays pH and temperature, with buttons for power, calibration, settings, and navigation. The electrode is connected via a BNC port and held by a stand.
  • Meter Unit: Main device housing the electronics, display, and control buttons.
  • LCD Display: 6.0-inch screen showing pH/mV readings, temperature, and status indicators.
  • Control Buttons:
    • Power: Turns the device on/off.
    • Calib: Initiates the calibration process.
    • Set: Accesses settings and configuration options.
    • Enter: Confirms selections.
    • Up/Down Arrows: Navigates menus and adjusts values.
  • pH Electrode: Sensor for measuring pH levels, connects via a BNC(Q9) input.
  • Electrode Stand: Provides stable support for the pH electrode during measurement and storage.

5. Setup

  1. Unpack: Carefully remove all components from the packaging.
  2. Assemble Electrode Stand: Attach the electrode stand to the meter unit or a stable surface as per the stand's design.
  3. Connect Electrode: Plug the BNC connector of the pH electrode into the BNC(Q9) input port on the back or side of the meter unit. Ensure a secure connection.
  4. Connect Power: Connect the DC9V output of the AC power adapter to the power input port on the meter. Plug the AC adapter into a standard electrical outlet.
  5. Prepare Electrode: Remove the protective cap from the pH electrode. Rinse the electrode with distilled water before initial use and between samples.

6. Operating Instructions

  1. Power On: Press the Power button to turn on the meter. The LCD display will illuminate.
  2. Measurement Mode: The meter typically defaults to continuous reading mode. Ensure the electrode is immersed in the sample or buffer solution.
  3. Temperature Compensation: The PH100B uses Manual Temperature Compensation (MTC). You may need to manually input the sample temperature for accurate pH readings if an external temperature probe is not used or if the meter does not automatically detect temperature. Refer to the 'Set' menu for temperature adjustment.
  4. Reading Stability: Allow a few moments for the reading to stabilize on the display before recording the value.
  5. Backlight: The display features a backlight for improved visibility. This can usually be toggled or configured in the settings menu.
  6. Auto Shutdown: The meter has an adjustable auto-shutdown feature (300, 600, 1200, 1800, 3600 seconds, or off) to conserve power. Configure this in the settings menu.
  7. Power Off: Press and hold the Power button to turn off the meter when not in use.

7. Calibration

Regular calibration is crucial for accurate pH measurements. The PH100B supports 1-2 points calibration with standard recognition using NIST buffers.

  1. Prepare Buffers: Have fresh NIST standard pH buffer solutions (e.g., pH 7.00, pH 4.00, pH 10.00) ready. Ensure they are at the same temperature as your samples.
  2. Rinse Electrode: Rinse the pH electrode thoroughly with distilled water and gently blot dry with a lint-free tissue.
  3. Initiate Calibration: Press the Calib button on the meter. The display will prompt you to immerse the electrode in the first buffer.
  4. First Point Calibration: Immerse the electrode into the first standard buffer (e.g., pH 7.00). The meter will automatically recognize the buffer and stabilize the reading. Once stable, confirm the calibration point (usually by pressing Enter or waiting for auto-confirmation).
  5. Second Point Calibration (Optional): If performing a 2-point calibration, rinse the electrode again with distilled water. The meter will then prompt for the second buffer (e.g., pH 4.00 or pH 10.00, depending on your expected sample range). Immerse the electrode and allow it to stabilize. Confirm the second calibration point.
  6. Exit Calibration: The meter will indicate when calibration is complete. Exit the calibration mode.
  7. Post-Calibration: Rinse the electrode and store it properly.

8. Maintenance

  • Electrode Cleaning: Regularly clean the pH electrode to remove any buildup from samples. Use distilled water for rinsing. For stubborn deposits, consult the electrode manufacturer's guidelines for specific cleaning solutions.
  • Electrode Storage: Always store the pH electrode in its protective cap, filled with a suitable electrode storage solution (e.g., 3M KCl solution). Never store it dry or in distilled water, as this can damage the electrode.
  • Meter Cleaning: Wipe the meter unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • IP54 Rating: The IP54 rating means the meter is protected from dust ingress and splashing water from any direction. While it offers protection, avoid submerging the unit or exposing it to strong jets of water.
  • Battery: The device includes a battery. If the meter is not holding a charge or functioning correctly, consult support for battery-related issues.

9. Troubleshooting

  • Inaccurate Readings:
    • Ensure the electrode is clean and properly stored.
    • Perform a fresh calibration with new, accurate buffer solutions.
    • Check for air bubbles on the electrode bulb during measurement.
    • Verify the manual temperature compensation setting is correct for your sample.
  • No Display/Power:
    • Check the power adapter connection and ensure the outlet is functional.
    • If using internal battery, ensure it is charged.
  • Slow Response:
    • The electrode may be dirty or nearing the end of its lifespan. Clean or replace if necessary.
    • Ensure the electrode junction is not clogged.
  • Error Messages: If an error code appears, refer to the specific error code section (if available in a more detailed manual) or contact customer support.

10. Specifications

Specifications table for PH100B Digital PH Meter
Figure 2: Detailed specifications for the PH100B Digital PH Meter.
CategoryParameterSpecification
pHModelPH100B
ParameterspH/mV
Range0.00 to 14.00 pH
Resolution0.01 pH
Accuracy± 0.01 pH
Calibration PointsUp to 2
Standard RecognitionNIST buffers
mVRange-1800 to 1800 mV
Resolution1 mV
Accuracy± 0.1% FS
MeasurementReading ModeContinuous
Temp. CompensationMTC (Manual Temperature Compensation)
InputspH ElectrodeBNC(Q9)
Display OptionsBacklightYes
Auto Shutdown300, 600, 1200, 1800, 3600 sec., off
IP RatingIP54
GeneralPowerAC Adapter, 100-240V AC input, DC9V output
Dimensions200 × 160 × 63 mm
Weight600g (1.32 Lb)
Battery IncludedYes

11. User Tips

No specific user tips were available from reviews or Q&A for this product. General best practices for pH meters include:

  • Always use fresh calibration buffers. Expired or contaminated buffers can lead to inaccurate readings.
  • Ensure the electrode is fully immersed in the solution during measurement and calibration.
  • Allow sufficient time for the meter reading to stabilize before recording.
  • Calibrate the meter frequently, especially if high accuracy is required or if measuring across a wide pH range.

12. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided at the point of purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.