1. Product Overview
The GlintDeer LCR-MF9 is a versatile multi-function tester designed for automatic detection and measurement of various electronic components. It features a 1.8-inch TFT LCD display for clear graphical results and includes functions for transistor testing, IR decoding, and more.
2. Safety & Warnings
- Do not use with incompatible devices / accessories to avoid affecting product performance or damaging related equipment.
- If the product shows any abnormal conditions such as smoke, unusual noises, or odors, immediately stop using it.
- This product is not food-related. Keep it away from children and avoid accidental ingestion / touching of sharp parts (if any).
- Warning: Always be sure to DISCHARGE capacitors before connecting them to the tester! The tester may be damaged before you have switched it on!
- Warning: We do not recommend using the tester to measure the battery! The battery voltage must be less than 4.5V, otherwise the tester may be damaged!
- Note: The instrument is active output, please do not use the test line to test the charged circuit board, easy to damage the instrument, the main performance is not to turn on.
3. Specifications
| Attribute Name | Attribute Value |
|---|---|
| Semi-finished product | Yes |
| Battery Included | no |
| High-concerned chemical | none |
| Is Smart Device | no |
| Operating Mode | Auto Range |
| Operating Temperature | 0 - 40 ℃ |
| Measuring Capacitance Range | 25pF-100mF |
| Certification | CE |
| DIY Supplies | Electrical |
| Measuring Resistance Range | 0.01-50MΩ |
| Measuring Inductance Range | 0.01mH-20H |
| Origin | Mainland China |
| Brand Name | GlintDeer |
| Dimensions | 60*90*27MM |
| DC Current | ESR |
| AC Current | MOSFET |
| DC Voltage | 3.7V |
| Display Type | Digital Display |
| AC Voltage | multimeter |
| GLINTDEER Model | LCR-MF9 |
Component Measurement Ranges & Parameters:
| Component Type | Range | Parameter Description |
|---|---|---|
| BJT | / | hFE (DC Current Gain), Ube (Base-Emitter Voltage), Ic (Collector Current), Iceo (Collector Cut-off Current (IB=0)), Ices (Collector short Current), Uf (Forward Voltage of protecting diode) |
| Diode | forward voltage <4.50V | Forward voltage drop, junction capacitance, reverse leakage current |
| Double Diode | forward voltage <4.50V | Forward voltage |
| Zener Diode (Transistor Test Area) | 0.01-4.50V | Forward voltage drop, reverse breakdown voltage |
| Zener Diode (KAA Test Area) | 0.01-20V | Reverse breakdown voltage |
| JFET | MOSFET | Cg (Gate Capacitance), Id (Drain Current) at Vgs (Gate to Source Threshold Voltage), Uf (Forward Voltage of protecting) |
| IGBT | MOSFET | Drain current Id under Vgs, protection diode forward voltage drop Uf |
| MOSFET | MOSFET | Turn-on voltage Vt, gate capacitance Cg, drain resistance Rds, protection diode forward voltage drop Uf |
| Thyristor | Gate trigger current <6mA | Gate turn-on voltage |
| Triac | Gate trigger current <6mA | Gate turn-on voltage |
| Capacitor | 25pF-100mF | Capacitance Value, Equivalent Series Resistance ESR, Vloss |
| Resistor | 0.01-50MΩ | Resistance |
| Inductor | 0.01mH-20H | Inductance, DC Resistance |
| Battery | 0.1-4.5V | Voltage value, battery polarity |
4. Setup
4.1 Initial Preparation
- Remove all protective films from the device.
4.2 KAA Test Area Activation (for Zener Diodes > 5V)
The KAA test area is turned off by default. To activate it:
- Ensure the tester is powered off.
- Press and hold the TEST key for approximately 15 seconds.
- The screen will display "KAA OFF" changing to "KAA ON" in the lower left corner, indicating the KAA test area is activated.
- The setting is automatically saved and does not need to be repeated.
Important Note: The output voltage of the KAA area is 20V. If a capacitor is accidentally placed here, it MUST be discharged before being placed into the transistor test area. Failure to discharge can immediately damage the instrument, potentially damaging test area pins or causing the machine to shut down permanently.
5. Operating Instructions
5.1 Power On & Basic Measurement
In the power-off state, a short press of the multi-function key will turn on the tester and initiate an automatic measurement.
5.2 Detecting Transistors and Other Components
To test a component:
- Ensure the tester is powered off or a previous test is completed.
- Insert the test element into the transistor test area of the test seat. The tester will automatically identify the pins.
- Press the locking handle to secure the component.
- Short press the multi-function key. The tester will automatically measure and graphically display the results.
The instrument is equipped with three lines for testing. For capacitors, it is recommended to insert them directly into the test area for more accurate results. Always discharge capacitors before testing.
5.3 Detecting Zener Diodes
For Zener diodes, especially those higher than 5V, use the dedicated Zener diode test area (KAA test area, refer to Setup section for activation).
- Ensure the tester is powered off or a previous test is completed.
- Insert the Zener diode into the Zener diode test area.
- Press the locking handle.
- Briefly press the multi-function button to start the test.
5.4 IR Decoder Function
The IR decoder supports Hitachi IR coding and displays IR waveforms.
- After a component test is completed, point an infrared remote control at the "IR" test hole of the tester.
- Press a button on the remote control.
- The tester will display the user code and data code upon successful decoding, along with the corresponding infrared waveform.
If decoding fails, the user code and data code will not be displayed. If you are in the tester interface, you cannot enter the infrared decoding interface. If you are already in the infrared decoding interface, the last successful decoding information will remain displayed.
6. Maintenance
6.1 Automatic Calibration
To ensure measurement accuracy, perform automatic calibration:
- Short-circuit the three test sockets (1, 2, and 3) in the transistor test area.
- Short press the multi-function button. The tester will automatically calibrate.
- During calibration, follow the on-screen prompts, such as disconnecting the short wire when instructed.
6.2 Battery Charging
The LCR-MF9 has a built-in rechargeable Li-ion battery. The charging interface is a standard Micro USB. Use an external 5V power supply or USB power supply for charging.
6.3 Battery Voltage Detection
Before each component measurement, the built-in lithium battery voltage is detected and displayed. If the battery voltage drops below 3.1V, the tester will automatically shut down, indicating that it needs to be charged.
6.4 Automatic Shutdown
The tester will automatically shut down after a set timeout (default 30 seconds) if no activity is detected after a component test or IR decoding. Standby power consumption is 0 UA after shutdown.
7. Troubleshooting
7.1 Common Issues & Solutions
| Question | Cause | Solution |
|---|---|---|
| Cannot power on | Lithium battery is low | Please charge until the light turns green |
| Inaccurate measurements | Please re-calibrate |
7.2 Known Errors and Unsolved Problems
- The current amplification factor of germanium transistors can be measured too high due to high residual current. In this case, the base-emitter voltage will be very low.
- Capacity value in reverse direction for Power Schottky Diodes such as MBR3045PT cannot be measured if only one diode is connected. The reason is a too big residual current of this diode. Sometimes the measurement is possible by cooling down the device (with cooling spray for example).
- The diode function of a triac gate cannot be examined.
- The Source and Drain pins cannot be detected correctly with JFETs. The reason is the symmetrical structure of these semiconductors. You can notice this problem if the display shows the same layout with the same parameters when the Source and Drain pins are swapped.
- The output current of the tester is 6mA / voltage <5V. High-power IGBTs, thyristors, and Darlington tubes that require higher current/higher voltage drive may not be measured.
- Air core coils and power inductors cannot directly measure inductance. It is recommended to try series connection.
- For capacitors below 20pF, it is recommended to test with a 20pF capacitor for appropriate color ring inductance test.
8. User Tips
- For more accurate measurements, consider performing a calibration if you notice inconsistencies.
- If the system freezes during a component check, disconnecting and reconnecting the battery may help reset the device.
9. Warranty & Support
Manufacturer & EU Representative Information:
- Country: China
- Telephone: +86-13417026232
- Email: xinhui0518@163.com
- Responsible Person: Ouyanghui
- EU Representative: eVatmaster Consulting GmbH
- EU Representative Address: Bettinastr. 30, 60325 Frankfurt am Main, Germany
- EU Representative Email: contact@evatmaster.com
- EU Representative Telephone: +49-6995179070
For further assistance, please contact the manufacturer or the EU representative using the provided details.
A detailed user manual in PDF format is also available: View User Manual (PDF)