1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Fangling F2500A and F2600 CNC Plasma Flame Gantry Cutting Machine Controller. This 2-axis control operating system is designed for precision cutting applications, offering advanced features for both plasma and flame cutting processes. Please read this manual thoroughly before operating the device to ensure safe and efficient use.
2. Specifications
2.1. Technical Indicators
- Control Axes: 2-axis linkage
- Control Accuracy: ±0.001mm
- Coordinate Range: ± 99999.99mm
- Maximum Pulse Frequency: 200KHz
- Maximum Operating Speed: 15 m/min
- Maximum Number of Program Lines: 80,000 lines
- Maximum Single Program Size: 4M
- Time Resolution: 10ms
- System Power Supply: DC +24V DC input, power greater than 80W
- System Working Environment: Temperature -10°C to +60°C; Relative humidity 0-95% non-condensing
- Maximum Driving Motor Power for Arc Voltage Adjustment: 45W (Note: Only available with T system). Up to 200W optional.
2.2. System Interface
- Motor Drive Interface: DB15 core male two-axis motor drive interface
- Output Interface: DB25-core female connector with 16 optically isolated outputs (max reverse current 300mA)
- Input Interface: DB25-core male connector with 16 optically isolated inputs (max input current 300mA)
- USB Interface: Front panel built-in USB interface (USB1.1, supports at least 16GB USB flash drive) for transferring cutting codes
- Serial Port: Optional standard DB9 core male serial port RS232 interface
2.3. Hardware Configuration
- Display: 15-inch industrial VGA high-brightness LCD screen
- Memory: 64M SDRAM
- User Program Space: 256M
- Main Frequency: 400MHZ system main frequency
- Keyboard: PCB film keyboard
- Chassis: All-steel structure, completely shielded for electromagnetic radiation, anti-interference, and anti-static protection.
2.4. Physical Dimensions
Refer to the diagram below for detailed dimensions for installation planning.

3. Setup and Installation
3.1. Safety Precautions
- Ensure the power supply is DC 24V.
- Do not open the chassis without authorization.
- Ensure the system is firmly grounded during installation.
- Do not open the chassis within 5 minutes after power off to avoid electric shock from residual charge.
3.2. Mounting the Controller
Use the provided dimensional drawings (Figure 2.4.1) to prepare the mounting location. Secure the controller using appropriate fasteners through the designated mounting holes.
3.3. Connecting Power
Connect a stable DC 24V power supply (greater than 80W) to the designated power input terminal on the back panel. Ensure correct polarity.

3.4. Interface Connections
Refer to the detailed pinout tables below for connecting input, output, and motor interfaces. Ensure all connections are secure and correctly wired to prevent damage to the controller or connected machinery.

3.4.1. Input Interface (DB25-core Male)
| Pin | Signal Name | Pin | Signal Name |
|---|---|---|---|
| 1 | Start | 14 | Left |
| 2 | Stop | 15 | Right |
| 3 | Up | 16 | Back |
| 4 | Down | 17 | Forward |
| 5 | Emergency | 18 | Arc Start |
| 6 | Arc Feedback | 19 | Arc Feedback |
| 7 | Plasma | 20 | Cutting Torch |
| 8 | Flame | 21 | Plasma |
| 11, 25 | +24V | 23 | 24VDC Power Supply |
| 24 | GND |
3.4.2. Output Interface (DB25-core Female)
| Pin | Signal Name | Pin | Signal Name |
|---|---|---|---|
| 1 | Plasma | 14 | Plasma |
| 2 | Flame | 15 | Flame |
| 3 | Up | 16 | Up |
| 4 | Down | 17 | Down |
| 5 | Arc Start | 18 | Arc Start |
| 6 | Arc Feedback | 19 | Arc Feedback |
| 7 | Cutting Torch | 20 | Cutting Torch |
| 8 | Plasma | 21 | Plasma |
| 9 | Flame | 22 | Flame |
| 11, 25 | +24V | 23 | 24VDC Power Supply |
| 24 | GND |
3.4.3. Motor Interface (DB15-core Male)
| Pin Number | Signal Name | Remarks |
|---|---|---|
| 1 | XDIR+ | Positive X-axis |
| 2 | XDIR- | X-axis direction negative |
| 3 | XCP+ | X-axis pulse positive |
| 4 | XCP- | X-axis pulse negative |
| 5 | YDIR+ | Y-axis positive |
| 6 | YDIR- | Y-axis direction negative |
| 7 | YCP+ | Y-axis pulse positive |
| 8 | YCP- | Y-axis pulse negative |
| 9 | Ubase | |
| 10 | +5V | +5V/500mA power output |
| 11 | 5VG | 5V power supply |
3.5. USB Connection
The front panel features a USB 1.1 interface. This is used for transferring cutting codes to the controller. Ensure your USB flash drive is formatted correctly and contains compatible files.
4. Operating Instructions
4.1. Power On and Initial Screen
Once all connections are secure and power is supplied, the controller will boot up. The 15-inch LCD screen will display the main operating interface. Use the PCB film keyboard for navigation and input.

4.2. Core Functions
- Program Management: Transfer cutting codes via the front USB interface. The system supports up to 80,000 program lines and a maximum single program size of 4M.
- Cutting Modes: The controller supports four distinct cutting modes: oxygen gas, plasma, powder spraying, and demonstration. Select the appropriate mode for your application.
- Oxygen Gas Cutting: Features automatic height adjustment, two-stage preheating, and three-stage perforation for optimal results.
- Plasma Cutting: Includes arc voltage feedback, positioning feedback, and automatic arc voltage adjustment for precise cuts. Supports dynamic plasma perforation.
- Edge Cutting: Utilize the edge cutting function to reduce preheating time, especially beneficial for thicker steel plates.
- Corner Speed Control: The system can automatically limit speed at corners based on steel plate thickness to prevent overheating and ensure cut quality.
- Starting Point Selection: Manually select the starting line or piercing point for your cutting path.
- Graphic Display: Dynamic and static processing graphics display with zoom in/out capabilities and dynamic tracking of cutting points in enlarged views.
- Offset Cutting: The "Offset cutting" function helps to avoid material waste caused by nesting calculation errors.
- Laser Pointing: The system supports a laser pointing function for precise alignment and setup.
- Standard Graphic Libraries: Access up to 48 standard graphic libraries directly from the system. These can be called out and parameters modified for fast cutting operations.


4.3. System Management
- User Rights: Different management rights and corresponding passwords can be set to protect equipment manufacturer interests and prevent unauthorized changes.
- Remote Control: Supports P2P mode or BCD (8421) and serial port RS232 remote control options.
- Data Statistics: The system provides information statistics including processing piece count, running time, and perforation times.
5. Maintenance
- Software Updates: The system supports convenient and simple U disk upgrade methods, providing lifetime upgrade service for software. Regularly check for and apply updates to ensure optimal performance and access to new features.
- Parameter Management: Utilize the parameter backup and restoration functions to safeguard your settings. It is recommended to back up critical parameters periodically.
- Cleaning: Keep the controller's screen and chassis clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using harsh chemicals or abrasive materials.
- Environmental Control: Ensure the operating environment adheres to the specified temperature (-10°C to +60°C) and humidity (0-95% non-condensing) ranges to prolong the lifespan of the device.
- Internal Access: As per safety warnings, do not open the chassis without authorization or within 5 minutes after power off. Internal maintenance should only be performed by qualified personnel.
6. Troubleshooting
This section addresses common issues you might encounter with your Fangling F2500A/F2600 controller. For problems not listed here, or if solutions do not resolve the issue, please contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Controller does not power on | Incorrect power supply voltage or insufficient power; loose power connection. | Verify power supply is DC 24V and greater than 80W. Check all power connections for secure fit. |
| Motors not responding | Loose motor cable connections; incorrect motor interface wiring; motor driver fault. | Check DB15 motor interface connections against the pinout table (Figure 3.4.1). Ensure motor drivers are powered and functional. |
| Input/Output signals not working | Incorrect wiring to DB25 connectors; faulty external sensors/actuators. | Review DB25 input/output interface wiring against the pinout tables (Figure 3.4.1). Test external components independently. |
| Cutting program errors or unexpected behavior | Corrupted cutting file; incorrect parameters; software glitch. | Re-upload the cutting file from a known good source. Check and restore parameters from a backup. Consider a system software update if available. |
| Screen display issues | Internal hardware issue; environmental factors. | Ensure operating environment is within specified temperature/humidity. If persistent, contact support. |
7. User Tips
- Regular Backups: Always back up your cutting programs and system parameters to a USB drive. This can save significant time in case of data loss or system reset.
- Clean USB Drives: Use a dedicated USB drive for transferring cutting codes to avoid introducing viruses or corrupted files to the controller.
- Parameter Tuning: Take time to understand and fine-tune cutting parameters for different materials and thicknesses. This will significantly improve cut quality and efficiency.
- Grounding is Key: Ensure your entire cutting system, including the gantry and plasma/flame source, is properly grounded to prevent electrical interference and ensure safety.
- Software Updates: Periodically check for software updates from the manufacturer. Updates often include performance improvements, bug fixes, and new features.
8. Warranty and Support
The Fangling F2500A/F2600 controller is designed for durability and reliability. The system offers a lifetime upgrade service for its software, ensuring your controller remains up-to-date with the latest features and improvements.
For specific warranty terms regarding hardware, or for technical support and service inquiries, please contact your original seller or authorized distributor. Provide your product model number (F2500A or F2600) and a detailed description of the issue when seeking support.