1. Introduction
The SUSWE SU900 series is a high-performance vector type frequency converter designed for precise control of three-phase motors. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VFD. Please read this manual thoroughly before use.

Image: Various models of SUSWE vector frequency inverters, illustrating the product line.
2. Safety Information
WARNING: Improper installation or operation can lead to serious injury or equipment damage. Always follow safety guidelines.
- Ensure the power supply is disconnected before any installation, wiring, or maintenance.
- Only qualified personnel should install and service this equipment.
- Verify correct voltage and current ratings before connecting.
- Ground the VFD properly to prevent electrical shock.
- Do not touch internal components while power is connected.
- Protect the VFD from moisture, dust, and corrosive environments.
3. Product Overview
The SUSWE SU900 series VFD features a robust design with advanced control capabilities. Key features include:
- High-performance vector control for precise motor speed and torque.
- Detachable smart panel for flexible operation and monitoring.
- Efficient DC fan for rapid heat dissipation.
- Industrial-grade anti-EMC power supply for stable operation.
- Three anti-paint process for enhanced durability in harsh environments.
- CE, FC, and RoHS certified for quality and safety.
3.1 Control Panel Functions
The interactive key panel allows for monitoring and adjustment of operating parameters.

Image: Front view of the SU900 VFD control panel, indicating the display area, speed control knob, displacement key, programming key, increment key, decrement key, run key, stop/reset key, confirm key, and multi-function keys.
- Display Area: Shows operating data such as speed, frequency, current, and voltage.
- Speed Control Knob: Adjusts the output frequency/speed.
- Displacement Key: Used for navigating through display digits or parameters.
- Programming Key (PRG): Enters/exits programming mode.
- Increment Key (▲): Increases parameter values or navigates up.
- Decrement Key (▼): Decreases parameter values or navigates down.
- Run Key (RUN): Starts the motor.
- Stop/Reset Key (STOP/RST): Stops the motor or resets alarms.
- Confirm Key (ENTER): Confirms parameter settings.
- Multi-function Keys (MFK): Customizable function keys.
3.2 Detachable Smart Panel
The VFD features a detachable smart panel that can be extended using a network cable for remote operation and monitoring, offering greater flexibility.

Image: The SU900 VFD with its detachable control panel connected via an external network cable.
4. Specifications
The SU900 series offers various power specifications and dimensions. Refer to the tables and diagrams below for detailed information.
4.1 Product Information
| Attribute | Description |
|---|---|
| Name | General purpose inverter |
| Input Voltage | 220V/380V |
| Input Frequency | 50/60Hz |
| Temperature Range | -20°C to +60°C |
| Motor Application | Suitable for fans and pumps |
| Scope of Use | Woodworking machinery, food machinery, textile machinery, plastic machinery, CNC machine printing machinery, automation, and other high motor control applications |
| Power Specifications | 0.75-45KW |
| Rated Current | 1.5-320A |
| Protection Level | IP20 |
| Cooling Mode | Self-cooling fan |
| Product Protection | 6 great protections |

Image: Detailed product information and specifications for the general purpose inverter.
4.2 Series Index and Dimensions
The following tables provide the frequency converter series index, including power supply, rated currents, and adapted motor power. Dimensions for external units are also provided.

Image: Table detailing the 800/900 series frequency converter index, including power supply, rated input/output current, kW, and HP for various models.

Image: Technical drawing showing dimensions for the C1 external unit, suitable for single-phase 220V (SU800-0R75G2 to SU800-2R2G3) and three-phase 380V (SU800-0R75G3 to SU900-2R2G3) models.

Image: Technical drawing showing dimensions for the C2 external unit, suitable for single-phase 220V (SU800-5R5G2, SU800-7R5G2) and three-phase 380V (S0800-4R0G3 to SU900-7R5G3) models.

Image: Technical drawing showing dimensions for the C3 external unit, suitable for three-phase 380V (SU900-7R5G3, SU900-11R0G3, SU900-15R0G3) models.

Image: Technical drawing showing dimensions for the C4 external unit, suitable for three-phase 380V (SU900-18R5G3, SU900-22R0G3) models.

Image: Technical drawing showing dimensions for the C5 external unit, suitable for three-phase 380V (SU900-18R5G3, SU900-22R0G3) models.
5. Setup
Before installation, carefully read the instructions to prevent dangerous occurrences and improper operation. Ensure all power is disconnected.
5.1 Wiring Diagrams
The VFD supports both 220V single-phase and 380V three-phase input configurations. Always ensure proper grounding.

Image: Side-by-side wiring diagrams for 220V single-phase and 380V three-phase VFD connections, showing power supply, motor, and ground wire connections.
220V Wiring Diagram:
- Power Supply: Output L and N connected to the power supply.
- Motor: Output U, V, W connected to the motor.
- Ground Wire: Connect to the designated ground terminal.
380V Wiring Diagram:
- Power Supply: Enter R, S, T for power.
- Motor: Output U, V, W connected to the motor.
- Ground Wire: Connect to the designated ground terminal.
5.2 Main Circuit Terminal Instructions
Refer to the table and control circuit diagram for detailed terminal connections.
| Terminal Marks | Name | Instruction |
|---|---|---|
| R, S, T / L, N | Power supply input terminals | Connection point of three-phase 380V / single-phase 220VAC power supply |
| P+, PB | Brake electric resistance connection terminals | Connect brake electric resistance |
| U, V, W | Frequency converter output terminals | Connect three-phase motor |
| Grounding terminals | Grounding terminals |

Image: Detailed wiring diagram for the frequency converter's main circuit and control circuit, including analog inputs, digital inputs, and communication ports.
Control Loop Terminal Note: The control circuit wiring of all 800/900 series inverters is the same. The diagram indicates the main loop terminal and represents the control loop terminal.
6. Operating Instructions
The SU900 VFD offers intuitive control through its interactive key panel. For detailed programming, refer to the comprehensive programming guide (not included in this manual).
6.1 Basic Operation
- Power On: Ensure all wiring is correct and secure, then apply power to the VFD.
- Set Frequency/Speed: Use the Speed Control Knob to adjust the desired output frequency. The current frequency will be displayed on the Display Area.
- Start Motor: Press the RUN key to start the motor.
- Stop Motor: Press the STOP/RST key to stop the motor.
- Reset Alarms: If an alarm occurs, address the cause, then press the STOP/RST key to reset the VFD.
6.2 Parameter Programming
To access and modify advanced parameters:
- Press the PRG key to enter programming mode.
- Use the ▲ (Increment) and ▼ (Decrement) keys to navigate through parameter groups and individual parameters.
- Use the Displacement Key to move the cursor within a parameter value.
- Use the ▲ and ▼ keys to change the parameter value.
- Press the ENTER key to confirm the new value.
- Press the PRG key again to exit programming mode.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD.
- Cleaning: Keep the VFD clean and free from dust. Use a soft, dry cloth. Do not use liquid cleaners.
- Cooling System: Ensure the DC cooling fan and heat sinks are free from obstructions. The intelligent start/stop function and aluminum alloy radiator provide efficient heat dissipation.
- Inspection: Periodically check all wiring connections for tightness and signs of wear or damage. Inspect the VFD for any visible damage or unusual noises during operation.
- Environment: Maintain the VFD in a dry, well-ventilated area, free from corrosive gases and excessive vibration. The three anti-paint process helps protect internal components in harsh environments.

Image: Close-up of the VFD's DC cooling fans, emphasizing efficient heat dissipation.
8. Troubleshooting
This section covers common issues you might encounter with your VFD. For more complex problems, consult a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor does not start | No power, incorrect wiring, parameter error, emergency stop active | Check power supply, verify wiring, review motor parameters, check for active emergency stop. |
| VFD displays an error code | Overcurrent, overvoltage, undervoltage, overload, overheating | Refer to the VFD's specific error code list (in the full manual) for diagnosis. Address the cause and press STOP/RST. |
| Motor runs erratically or at incorrect speed | Incorrect frequency setting, motor parameters mismatch, poor motor connection | Adjust frequency, verify motor parameters (e.g., rated voltage, current, frequency), check motor wiring. |
| Excessive noise or vibration | Motor imbalance, mechanical issue, VFD parameter tuning | Check motor and load for mechanical issues. Adjust VFD tuning parameters (e.g., carrier frequency, acceleration/deceleration times). |
9. User Tips
- Initial Setup: Always double-check your wiring against the provided diagrams before applying power. Incorrect wiring is a common cause of initial setup issues.
- Parameter Backup: After successfully configuring your VFD, it's good practice to record your parameter settings. This can save time if a reset is ever needed.
- Motor Tuning: For optimal performance, especially with vector control, consider performing an auto-tuning function (if available in your model) to match the VFD to your specific motor characteristics.
- Environmental Considerations: While the VFD is designed for harsh environments, ensuring good ventilation and keeping it away from direct moisture and excessive dust will extend its lifespan.
10. Warranty and Support
The SUSWE SU900 series frequency converter comes with a one-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance, or warranty claims, please contact your authorized dealer or SUSWE customer service. Please have your model number and purchase details ready.

Image: Display of CE, FC, and RoHS certifications, indicating product compliance and quality.