This manual provides detailed instructions for the safe and effective use of your Braun Ear Thermometer, specifically models IRT-6510, IRT-6030, and IRT-6525KO. Please read all instructions carefully before use and keep this manual for future reference. This device is designed for accurate temperature measurement in the ear.
Product Overview
The Braun Ear Thermometer is an advanced infrared thermometer designed for precise and comfortable temperature readings. Key features include:
- Exactemp Positioning System: Guides you to the correct ear canal position for accurate readings.
- Pre-warmed Tip Technology: Minimizes the cooling effect of the probe in the ear canal, preventing inaccurate temperature results.
- Memory Function: Stores previous temperature readings for tracking. (IRT-6510: 9 memories, IRT-6030: 1 memory)
- LCD Display: Clear digital display of temperature.
- Disposable Lens Filters: Ensures hygienic use and accurate readings.
- Protective Case: Includes storage for lens filters.
- AgeSmart™ Technology (IRT-6525KO only): Provides age-specific fever guidance with color-coded display.
- Night Mode (IRT-6525KO only): Features illumination and a silent mode for nighttime measurements.



Setup
- Insert Batteries: Open the battery compartment and insert two 1.5V AA (LR06) batteries, ensuring correct polarity.
- Remove from Case: Gently remove the thermometer from its protective storage case.
- Remove LCD Sticker: If this is the first use, carefully peel off any protective sticker from the LCD screen.
- Attach Lens Filter: Always attach a new, clean disposable lens filter to the thermometer probe before each use. Ensure it clicks securely into place.
Operating Instructions
Follow these steps for accurate temperature measurement:
- Power On: Press the power button (I/O) to turn on the thermometer.
- Attach New Filter: Ensure a new, clean disposable lens filter is securely attached to the probe.
- Position in Ear: Gently insert the probe firmly into the ear canal. For accurate readings, the temperature sensor must be properly positioned.
- Start Measurement: Press and release the start button.
- Read Temperature: The measured temperature will be displayed on the LCD screen.
- Remove Used Filter: After measurement, press the lens filter release button to detach the used lens filter.
- Discard Filter: Dispose of the used lens filter immediately. Do not reuse lens filters.


Maintenance
Proper maintenance ensures the longevity and accuracy of your thermometer:
- Cleaning the Probe: After removing the disposable lens filter, gently wipe the probe and tip with an alcohol swab or a soft cloth dampened with alcohol. Allow it to dry completely before storing.
- Cleaning the Device Body: Wipe the main body of the thermometer with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the thermometer in its protective case at room temperature, away from direct sunlight and moisture.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display. Use two 1.5V AA (LR06) batteries.
Troubleshooting
If you encounter issues with your thermometer, consider the following:
Factors Affecting Measurement Accuracy:
- Improper Probe Positioning: Ensure the temperature sensor is accurately positioned in the ear canal.
- Reusing Lens Filters: Always use a new, clean Braun lens filter for each measurement. Reusing filters can lead to inaccurate readings and hygiene issues.
- Unclean Lens: If the lens is not clean, it can affect accuracy. Ensure the lens is clean before attaching a new filter.
Factors Causing Low Temperature Readings:
- Low Ear Canal Temperature: If the ear canal temperature is unusually low, it may result in a lower reading.
- Improper Insertion: Incorrect insertion of the probe can lead to inaccurate low readings.
- Sweating: Excessive sweating can affect skin temperature and lead to lower readings.
If you suspect any of these factors, wait approximately 20 minutes before taking another temperature measurement.

Specifications
| Specification | Value |
|---|---|
| Commodity Quality Certification | FDA |
| Item Type | Household Health Monitors Accessories |
| Operating Temperature | 10°C ~ 40°C (50°F ~ 104°F) |
| Storage Temperature | -25°C ~ 55°C (-13°F ~ 131°F) |
| Operating & Storage Humidity | 10 ~ 95% RH (non-condensing) |
| Battery Type | 2 x 1.5V AA (LR06) |
User Tips
- Always use a new, clean disposable lens filter for each measurement to ensure hygiene and accuracy.
- Ensure the thermometer probe is inserted firmly and correctly into the ear canal to get the most accurate reading.
- If you take multiple readings, allow a short pause between measurements to let the ear canal temperature stabilize.
- Keep the thermometer and lens filters out of reach of children.
Warranty and Support
This product is a medical device. Please read the precautions and usage methods carefully before use.
For customer support or inquiries, please contact:
- Customer Service Center: 1588-6237 (Korea)
- Website: www.braunhealthcare.com/kr/