1. Introduction
The GEYA GP3-VA is a versatile Din Rail mounted protective device designed to safeguard household electrical equipment from overvoltage, undervoltage, and overcurrent conditions. This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of your GP3-VA protector.

Figure 1: GEYA GP3-VA Voltage and Current Protector
2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by trained and qualified professionals.
- Always observe local safety codes and relevant operating procedures during installation, operation, and maintenance.
- Failure to follow these instructions may result in personal injury or equipment damage.
- The device operates at low voltage (below 50Vac or 75Vdc) according to EU LVD Voltage standards.
- Ensure the power supply is disconnected before any installation or wiring work.
- Do not operate the device if it appears damaged.
3. Product Overview
3.1. Features
- Overvoltage Protection
- Undervoltage Protection
- Overcurrent Protection
- Adjustable protection values and delay times
- Digital display for real-time voltage and current
- Din Rail mounting for easy installation
3.2. Front Panel Layout

Figure 2: Front Panel with Display and Buttons
Indicators:
- >V: Overvoltage Indicator
- <V: Undervoltage Indicator
- >A: Overcurrent Indicator
- POWER: Normal Working Indicator
Buttons:
- ▲: Digit+/Up (Menu selection, increase value)
- ▼: Digit-/Down (Menu selection, decrease value)
- SET: Menu selection / Save settings
- ON/OFF: Power on/off
4. Specifications

Figure 3: Technical Parameters and Current Specifications
| Feature | Value |
|---|---|
| Type | Voltage relay |
| Rated Voltage | 220VAC |
| Rated Supply Voltage | AC220V(L-N) |
| Rated Frequency | 50/60Hz |
| Rated Operational Current | 40A / 63A |
| Over Voltage Operation Value | 230V~300V (Factory default: 280V) |
| Under Voltage Operation Value | 140V~210V (Factory default: 160V) |
| Voltage Protection Action Time | 0.1-30S (Factory default: 1S) |
| Over Current Protection Value | 1-40/63A/off (Factory default: 40/63A) |
| Over Current Protection Action Time | 0.1-30S (Factory default: 1S) |
| Continuous Overcurrent Protect Times | A01-A20/oFF (Factory default: OFF) |
| Recovery Delay Time | 1-600S (Factory default: 5S) |
| Reset Time | 1~600s (Factory default: 5s) |
| Mounting | Din Rail |
| Certification | CE |
| Wireless Functionality | No |
| Battery Included | No |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
| Smart Device | No |
| Dimensions (L*W*H) | 81*36*66mm |
| Altitude | ≤2000m |
| Permissible Relative Humidity | ≤50% at 40°C (without condensation) |
| Ambient Temperature | -25°C~+55°C |
5. Installation
The GP3-VA protector is designed for Din Rail mounting. Follow these steps for proper installation:
- Ensure the main power supply is completely disconnected before beginning installation.
- Mount the device onto a standard 35mm Din Rail in your electrical distribution box.
- Refer to the wiring diagram for correct connection of input (IN) and output (OUT) terminals.
- Ensure all connections are secure and tightened to prevent loose contacts.

Figure 4: Side view showing Din Rail mounting mechanism
6. Wiring Diagram
Connect the device according to the following diagram. Ensure 'N' (Neutral) and 'L' (Live) connections are correct for both input and output.

Figure 5: Wiring Diagram and Dimensional Drawing
7. Operation and Function Setting
The GP3-VA allows for adjustable protection parameters. Use the front panel buttons (▲, ▼, SET) to navigate and modify settings.
7.1. Setting Parameters
- Press the SET button to enter the menu settings.
- Use the ▲ (Up) and ▼ (Down) buttons to navigate through the parameters.
- To modify a parameter value, press SET when the desired parameter is displayed. Then use ▲ and ▼ to adjust the value.
- Long press ▲ or ▼ to quickly adjust figures.
- After setting the value, press SET again to confirm and move to the next parameter, or long press SET for 5 seconds to save all changes and exit the setting mode.
7.2. Available Parameters

Figure 6: Function Setting Flow Chart
- UP (Over-voltage protection value): Adjustable from 230V to 300V (or OFF). Factory default: 280V.
- Lo (Under-voltage protection value): Adjustable from 140V to 210V (or OFF). Factory default: 160V.
- Ut (Voltage protection action time): Adjustable from 0.1S to 30S. Factory default: 1S.
- PC (Over-current protection value): Adjustable from 1A to 40A/63A (or OFF). Factory default: 40A/63A.
- Ct (Over-current protection action time): Adjustable from 0.1S to 30S. Factory default: 1S.
- CC (Continuous overcurrent protect times): Adjustable from A01 to A20 (or OFF). Factory default: OFF.
- At (Recovery delay time): Adjustable from 1S to 600S. Factory default: 5S.
- P-1 (Power-on delay time): Adjustable 5-999S.
- P-2 (Recovery delay): Adjustable 15-999S.
- P-4 (Overvoltage recovery value): Adjustable 125V-295V.
- P-6 (Undervoltage recovery value): Adjustable 85V-215V.
- P-8 (Voltage Correction): Real-time voltage data -10%~+10%V.
- P-11 (Overcurrent counter): OFF or 0-20 times.
- P-12 (Current adjustment): Real-time current data -10%~+10%A.
- P-13 (Frequency adjustment): Real-time frequency data -2.5%~+2.5%Hz.
- P-14 (Quick power down protection): ON/OFF.
- P-15 (Three models): 1:Standard, 2:Manual, 3:Automatic.
- P-16 (Automatic reset): ON/OFF.
- P-17 (Switch mode): ON/OFF.
- P-18 (Energy saving mode): OFF/ON.
- P-19 (Password setting): 112 (default) or 000-999.
Note: Under DC power, only voltage is displayed, current is not.
8. User Tips
- Always ensure the device is correctly wired according to the diagram to avoid malfunction or damage.
- Regularly check the display for current voltage and current readings to monitor your electrical system.
- Familiarize yourself with the factory default settings and adjust them only if necessary for your specific application.
- When setting delay times, consider the type of load and potential transient events to prevent nuisance tripping.
9. Troubleshooting
- Device not powering on: Check input wiring (N, L) and ensure power supply is active.
- Incorrect voltage/current readings: Verify wiring connections. If the issue persists, consider using the voltage/current correction parameters (P-8, P-12) if you have a calibrated reference.
- Frequent tripping: Review your set overvoltage, undervoltage, and overcurrent protection values (UP, Lo, PC) and their respective action times (Ut, Ct). Adjust them if they are too sensitive for your load. Check for actual electrical anomalies in your system.
- Cannot save settings: Ensure you long-press the SET button for 5 seconds to save changes.
10. Maintenance
- Keep the device clean and free from dust and moisture.
- Periodically check all wiring connections for tightness and signs of wear or damage.
- Ensure adequate ventilation around the device to prevent overheating.
- Do not attempt to repair the device yourself. Contact qualified personnel for service.
11. Warranty and Support
GEYA products are manufactured to high standards. For any after-sales service or support, please contact your supplier or the GEYA Official Store. We are committed to providing excellent products and service.

Figure 7: GEYA Contact Information
12. About GEYA
GEYA Electric, established in 2007, is a private-owned enterprise specializing in the research, manufacture, and sales of low voltage electrical and automatic controlling products. The company is located in Wenzhou City and is dedicated to top quality and constant innovation. GEYA products are certified to required industry standards, including CCC, CE, CB, SAA, SEMKO, TUV, and Rosh.
Video 1: GEYA Company Overview

Figure 8: GEYA Company Information and Certifications