1. Introduction
The SUSWE SU800 series Variable Frequency Drive (VFD) is a high-performance vector control frequency converter designed for precise control of three-phase motors. It offers features such as constant pressure water supply, fan speed regulation, and energy saving capabilities. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VFD.

Image: SUSWE SU800 VFD highlighting vector control and power range (0.75KW-7.5KW).
2. Safety Information
Before installation, operation, or maintenance, carefully read and understand all instructions to prevent dangerous occurrences and improper operation that could lead to equipment damage or personal injury. Always ensure the power supply is disconnected before performing any wiring or maintenance tasks.
- Ensure proper grounding of the VFD and connected motor.
- Do not operate the VFD with wet hands or in damp environments.
- Verify correct voltage and current ratings before connecting to power.
- Only qualified personnel should perform installation and wiring.
- Allow sufficient time for capacitors to discharge after power-off before touching internal components (typically 5 minutes).
3. Product Overview
The SU800 VFD features a robust design with well-known brand components and a three anti-paint process for enhanced durability in harsh environments. It includes a detachable smart panel for flexible operation and monitoring.
3.1 Key Features
- High-performance vector control
- Power range: 0.75KW - 7.5KW (for SU800 series)
- Input/Output Voltage: 3-phase 380V (also available in 1-phase 220V for some models)
- Output Frequency: 50/60Hz
- Detachable smart panel for remote operation
- Efficient DC fan for rapid heat dissipation
- Six levels of product protection
- Industrial circuit board SMT welding process for reliability
3.2 Control Panel
The VFD is equipped with a user-friendly man-machine interactive key panel. This panel allows for monitoring of operating data such as speed, frequency, current, and voltage, and provides controls for operation.

Image: SU800 VFD with detachable smart panel and network cable connector.

Image: SU800 VFD with the detachable panel connected via network cable.

Image: Man-machine interactive key panel of the SU800 VFD with labeled controls including display area, speed control knob, programming key, run key, stop/reset key, increment/decrement keys, and multi-function keys.
4. Specifications
The following table details the general product information and specifications for the SUSWE VFD series. Specific models within the SU800/SU900 series may vary in power and dimensions.
| Parameter | Description |
|---|---|
| Name | General purpose inverter |
| Power Specifications | 0.75 - 45KW (series range) |
| Input Voltage | 220V/380V |
| Rated Current | 1.5 ~ 320A |
| Input Frequency | 50/60HZ |
| Protection Level | IP20 |
| Temperature Range | -20 ~ +60°C |
| Cooling Mode | Self-cooling fan |
| Motor Compatibility | Suitable for fans and pumps |
| Product Protection | 6 great protections |
| Scope of Use | Woodworking machinery, food machinery, textile machinery, plastic machinery, CNC machine printing machinery, automation, and other applications requiring higher motor control. |
| Certifications | CE, RoHS, FC |
For detailed power specifications and adapted motor ratings for various models (SU800-0R75G2 to SU900-45R0G3), please refer to the 'Frequency converter series index' table below.

Image: Table detailing frequency converter series index for single-phase and three-phase power supply, including power capacity, rated input current, rated output current, adapted motor kW/HP.
4.1 Dimensions
Dimensions vary by model. Below are examples for different external unit sizes (C1, C2, C3, C4, C5).

Image: Dimension parameters for C1 external unit, suitable for models like SU800-0R75G2, SU800-1R5G2, SU800-2R2G2 (220V) and SU800-0R75G3, SU800-1R5G3, SU800-2R2G3 (380V).

Image: Dimension parameters for C2 external unit, suitable for models like SU800-5R5G2, SU800-7R5G2 (220V) and SU800-4R0G3, SU800-5R5G3, SU800-7R5G3 (380V).

Image: Dimension parameters for C3 external unit, suitable for models like SU900-7R5G3, SU900-11R0G3, SU900-15R0G3 (380V).

Image: Dimension parameters for C4 external unit, suitable for models like SU900-18R5G3, SU900-22R0G3 (380V).

Image: Dimension parameters for C5 external unit, suitable for models like SU900-18R5G3, SU900-22R0G3 (380V).
5. Setup & Installation
Proper installation is crucial for the safe and reliable operation of the VFD. Ensure all connections are secure and comply with local electrical codes.
5.1 Wiring Diagrams
The wiring for the VFD is designed to be straightforward. Refer to the diagrams below for 220V and 380V systems. Always ensure the power supply is disconnected before making any connections.

Image: Wiring diagram showing connections for 220V (single-phase input) and 380V (three-phase input) systems. Includes power supply, ground wire, and motor connections (U, V, W).
5.2 Main Circuit Terminal Instructions
The following table provides detailed instructions for connecting the main circuit terminals of the frequency converter.
| Terminal Marks | Name | Instruction |
|---|---|---|
| R, S, T/L, N | Power supply input terminals | Connection point of three-phase 380V / single-phase 220Vac power supply |
| P+, PB | Brake electric resistance connection terminals | Connect brake electric resistance |
| U, V, W | Frequency converter output terminals | Connect three-phase motor |
| Grounding terminals | Grounding terminals |
The control circuit wiring for all 800/900 series inverters is similar. The diagram below illustrates the three-phase 380V converter wiring, indicating the main loop terminals and control loop terminals.

Image: Wiring method diagram for the frequency converter control circuit, showing connections for input, output, braking resistance, analog input, open collector output, high-speed pulse output, relay, and RS485 communication.
6. Operation
Operating the SU800 VFD involves powering it on, initiating motor operation, adjusting speed, and safely stopping the motor. The detachable panel provides an intuitive interface for these actions.
6.1 Basic Operation Steps
- Power On: Turn on the main power switch to supply three-phase 380V (or appropriate voltage) to the VFD.
- Start Operation: Press the RUN key on the control panel to start the operation of the converter and the connected motor.
- Adjust Speed: Turn the speed control knob to control the rotation speed of the motor. Turning it clockwise increases speed, counter-clockwise decreases speed.
- Stop Operation: Press the STOP/RESET button to gradually stop the motor.
- Power Off: Once the motor has come to a complete stop, pull down the main power switch to disconnect power to the VFD.
6.2 Operation Demonstration Video
Watch this video for a visual guide on the basic operation of the VFD, including starting, speed adjustment, and stopping the motor.
Video: Demonstration of VFD motor speed control, showing power-on, run, speed adjustment via knob, stop, and power-off sequence.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD.
- Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for external cleaning. For internal cleaning, ensure power is disconnected and capacitors are discharged, then use compressed air to remove dust from heat sinks and fans.
- Cooling System: Periodically check the DC cooling fan for proper operation and ensure air vents are not obstructed. The VFD features an efficient DC fan for rapid heat dissipation.
- Connections: Inspect all wiring connections for tightness and signs of wear or corrosion.
- Environment: Ensure the operating environment remains within the specified temperature range (-20°C to +60°C) and humidity levels.
- Firmware: Consult SUSWE support for information on firmware updates, if available.
8. Troubleshooting
This section provides solutions to common issues you might encounter with your VFD. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor not starting | No power, incorrect wiring, parameter settings, emergency stop active. | Check power supply, verify wiring (refer to Section 5), check parameter settings, ensure emergency stop is disengaged. |
| Motor running erratically | Loose connections, motor overload, interference. | Inspect wiring, reduce motor load, check for electromagnetic interference. |
| Overcurrent/Overvoltage fault | Sudden load changes, incorrect acceleration/deceleration times, power supply fluctuations. | Adjust acceleration/deceleration times, check power supply stability, ensure motor is not oversized. |
| Overheat fault | Blocked fan, high ambient temperature, VFD overload. | Clean fan and vents, ensure adequate ventilation, reduce VFD load. |
| Display not working | No power, panel connection issue. | Check power supply, ensure detachable panel is securely connected. |
9. User Tips
- Parameter Tuning: For optimal performance, especially in specialized applications like constant pressure water supply or specific machinery, fine-tune the VFD parameters according to your motor and load characteristics. Refer to the detailed programming guide (if available) for advanced settings.
- Cable Management: Use shielded cables for motor connections to minimize electromagnetic interference, especially in industrial environments. Keep power and control wiring separate.
- Environmental Control: While the VFD is designed for harsh environments with its three anti-paint process, maintaining a clean, dry, and well-ventilated installation area will significantly extend its lifespan.
- Remote Panel: Utilize the detachable smart panel with an external extension network cable for convenient monitoring and adjustment of working conditions from a distance, enhancing flexibility and ease of use.
10. Warranty & Support
The SUSWE SU800 VFD comes with a one-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance, or warranty claims, please contact your authorized SUSWE dealer or the manufacturer's customer service. Keep your purchase receipt as proof of warranty.

Image: Certificates of Compliance (CE, RoHS, FC) for the VFD, indicating adherence to international quality and safety standards.