1. Product Overview

The Meterk VT-ER3 is a versatile 5-in-1 electromagnetic radiation detector designed for comprehensive environmental monitoring. It simultaneously measures radio frequency (RF) field intensity, electric field strength, magnetic field strength, ambient temperature, and humidity. This device is equipped with a built-in electromagnetic radiation sensor that processes and displays radiation values on a 2.8-inch TFT digital screen.

Key features include sound alarms, lock screen/data locking, radiation level assessment, and battery level indication. Its dual-style display interface allows users to switch between different views, including trend graphs for all five parameters, providing intuitive visualization of data changes. The VT-ER3 is suitable for a wide range of applications, from industrial facilities and offices to homes and areas near signal towers, helping to ensure a safer and healthier living and working environment.

VT-ER3 Electromagnetic Radiation Detector showing 5 detection capabilities
Figure 1: VT-ER3 Detector highlighting its 5-in-1 detection capabilities.
Application scenarios for the VT-ER3 detector including home, office, factory, signal tower, and microwave oven
Figure 2: Common application scenarios for the VT-ER3 detector.

2. Setup

2.1 Unpacking and Initial Inspection

Carefully remove the VT-ER3 detector from its packaging. Inspect the device for any signs of damage. Ensure all components listed in the packing list are present:

  • 1 x Electromagnetic Radiation Detector (VT-ER3)
  • 1 x USB Type-C Charging Cable (not explicitly listed but implied by charging mode)
  • 1 x User Manual (this document)

2.2 Charging the Device

The VT-ER3 is equipped with a built-in 2000mAh battery. Before first use, it is recommended to fully charge the device.

  1. Locate the Type-C charging port on the device.
  2. Connect the provided Type-C USB cable to the device and the other end to a 5V USB power adapter (not included) or a computer USB port.
  3. The battery indicator on the display will show the charging status.
  4. Once fully charged, disconnect the charging cable.

2.3 Initial Settings

Upon powering on for the first time, you may need to configure basic settings such as language and alarm thresholds.

  1. Press the power button to turn on the device.
  2. Navigate to the 'Settings' menu using the control buttons (ESC, A, B, C, D, Arrow keys, OK).
  3. Select 'Language' and choose your preferred language.
  4. Configure 'Alarm setting' as described in section 3.3.
Multiple functions settings menu on VT-ER3 detector
Figure 3: The 'Settings' menu, allowing access to various device configurations.

3. Operating Instructions

3.1 Power On/Off

  • Power On: Press and hold the power button (usually the 'OK' button or a dedicated power button) until the screen illuminates.
  • Power Off: Press and hold the power button until the device shuts down, or navigate to the 'Settings' menu and select 'Power-off time' to configure automatic shutdown.

3.2 Display Modes

The VT-ER3 offers two styles of display pages for viewing detection data. You can switch between these modes by pressing the 'A' key.

Two display styles of the VT-ER3 detector, showing detection values and alert thresholds
Figure 4: Two distinct display styles for real-time data monitoring.

3.3 Reading Measurements and Alarm Function

The device displays real-time measurements for Electric Field, Magnetic Field, RF Strength, Temperature, and Humidity. It also features an alarm function:

  • Real-time Data: The main screen shows current readings for all five parameters.
  • Alarm Thresholds: You can set custom alarm values for Electric Field, Magnetic Field, and RF Strength in the 'Alarm setting' menu.
  • Visual Alert: If any detected value exceeds its set alarm threshold, the corresponding font color on the display will turn red to alert you to a high radiation level.
Alarm setting screen on the VT-ER3 detector, showing options for alarm function, time, and thresholds for electric field, magnetic field, and RF strength
Figure 5: Alarm settings interface for customizing alert thresholds.

3.4 Viewing Trend Graphs

The VT-ER3 supports viewing trend graphs for all five parameters, allowing you to visualize data changes over time.

  1. From the main detection screen, navigate to the 'Chart' option (usually using the arrow keys and 'OK').
  2. Select the parameter for which you want to view the trend graph (e.g., RF Strength, HUMI, Electric Field, Temperature, Magnetic Field).
  3. The screen will display a graph showing the historical data trend for the selected parameter.
Trend diagrams for RF Strength, Humidity, Electric Field, Temperature, and Magnetic Field on the VT-ER3 detector
Figure 6: Trend graphs for the five measured parameters.

3.5 Lock Screen / Data Locking

The device includes a lock function to prevent accidental changes to settings or to hold current readings on the screen.

  • To lock the screen or data, navigate to the 'Lock' option on the main interface and press 'OK'.
  • To unlock, repeat the action or follow on-screen prompts.

4. Maintenance

4.1 Cleaning

To ensure optimal performance and longevity of your device:

  • Wipe the device with a soft, dry cloth.
  • Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the casing or screen.
  • Keep the sensor areas clear of dust and debris.

4.2 Sensor Calibration

If you suspect the test data is deviating or inaccurate, the sensors can be calibrated separately.

  1. Navigate to the 'Settings' menu.
  2. Select 'Senser calibration'.
  3. Choose the specific sensor you wish to calibrate: 'Electric field calibration', 'Magnetic field calibration', or 'RF Strength calibration'.
  4. Follow the on-screen instructions to perform the calibration. Refer to professional calibration standards if available.
Sensor calibration screen on the VT-ER3 detector, showing options for electric field, magnetic field, and RF strength calibration
Figure 7: Sensor calibration options for maintaining accuracy.

4.3 Battery Care

  • Avoid fully discharging the battery frequently.
  • Charge the device regularly, especially if it will be stored for an extended period.
  • Store the device in a cool, dry place when not in use.

5. Troubleshooting

Problem Possible Cause Solution
Device does not power on Low battery; Device malfunction Charge the device fully. If still unresponsive, contact support.
Inaccurate readings Sensor deviation; Environmental interference Perform sensor calibration (see Section 4.2). Move to an area with less interference.
Alarm not sounding Alarm function disabled; Volume too low Check 'Alarm setting' in the menu to ensure it's enabled and thresholds are set correctly. Adjust 'Sound setting' volume.
Screen unresponsive Device frozen; Screen lock active Try restarting the device. Check if the screen lock is active and unlock it.

6. Specifications

Parameter Value
Model VT-ER3
Brand Meterk
Material Plastics
Battery 1 * 2000mAh (included)
Display Size 2.8 inch
Charging Mode 5V Type-C
Item Size 125 * 67 * 35mm (4.92 * 2.64 * 1.38in)
Item Weight 225g (7.94oz)
Certification FCC

6.1 Parameter Display Ranges

Measurement Range
Electric Field Strength 0-999.9 V/m
Magnetic Field Strength 0-999.99 μT
RF Strength / Power Density 0-999.99 mW/㎡
Temperature 0-70 ℃
Humidity 0-99 %RH

6.2 Frequency Ranges

Measurement Frequency Range
Electric Field Strength 20Hz-100MHz
Magnetic Field Strength 20Hz-1MHz
RF Strength / Power Density 50MHz-5GHz

6.3 Detection Accuracy

Measurement Accuracy
Electric Field Strength 0.1 V/m
Magnetic Field Strength 0.01 μT
RF Strength / Power Density 0.01 mW/㎡
Temperature 1 ℃
Humidity 1 %RH
Product parameters table for VT-ER3, showing color, model, screen size, battery, item size, charging method, and parameter display ranges
Figure 8: Product parameters and display ranges.
Frequency range and test accuracy table for VT-ER3
Figure 9: Frequency ranges and detection accuracy.

7. Warranty and Support

The Meterk VT-ER3 Electromagnetic Radiation Detector is designed for reliability and performance. For any issues not covered in this manual, or for warranty claims, please contact the seller or manufacturer directly. Keep your proof of purchase for warranty validation.

Please note that specific warranty terms and conditions may vary by region and retailer. Refer to the documentation provided at the time of purchase for detailed warranty information.

8. User Tips

  • Language Setting: The device supports multiple languages. If the menu is not in your preferred language, navigate to the 'Settings' menu (Figure 3) and select 'Language' to change it. (Based on Q&A: "Is the menu in Russian?")
  • Display Customization: Utilize the 'A' key to switch between the two available display styles (Figure 4) to find the view that best suits your monitoring needs.
  • Alarm Configuration: Take advantage of the customizable alarm thresholds (Figure 5) to receive immediate visual alerts when radiation levels exceed your predefined safe limits. This is particularly useful for continuous monitoring in specific areas.
  • Trend Analysis: Use the 'Chart' function (Figure 6) to observe long-term trends in radiation, temperature, and humidity. This can help identify patterns or intermittent sources of radiation.
  • Regular Calibration: For critical measurements, consider performing sensor calibration periodically, especially if you notice inconsistent readings or after significant environmental changes (Figure 7).
Documents and downloads