1. Introduction

The Aideepen T2310 is a versatile microcomputer time controller designed to manage the on/off cycles of various electrical loads based on user-defined timing parameters. It features a 1.37-inch LCD display and supports multiple voltage inputs (DC12V, DC24V, AC110V~220V), making it suitable for a wide range of applications. This device functions as a countdown timer with various timing units and cycle modes, offering precise control over your equipment.

Video: Overview of the T2310 Digital Time Controller features and capabilities.

Aideepen T2310 Digital Time Controller front view with green and red LED display

Figure 1: Front view of the T2310 Digital Time Controller.

2. Setup

2.1. Unpacking

Carefully unpack the T2310 Digital Time Controller and ensure all components are present. Inspect the device for any visible damage.

2.2. Installation

The T2310 is designed for embedded installation. This requires creating an opening in your mounting surface. The recommended hole size for mounting is 63mm x 42mm. The overall product size is 67mm x 45mm x 34mm. No screws are required for mounting once the opening is prepared.

2.3. Wiring

IMPORTANT SAFETY WARNING: This product is a direct output controller. To prevent accidents and ensure safe operation, always connect the load to the controller before turning on the power supply.

Warning symbol: electrical hazard

Warning: Electrical Hazard. Connect load before power.

Refer to the following diagrams for correct wiring based on your power supply type (DC or AC):

Wiring diagram for DC12V/24V and AC110V~220V connections. DC shows L/+ and N/- terminals for input, ON and OL for load. AC shows L and N terminals for input, ON and OL for load.

Figure 2: Wiring Diagram for DC12V/24V and AC110V~220V.

Detailed wiring diagram showing IN (L/+, N/-) and OUT (ON, OL) terminals for both DC and AC power sources.

Figure 3: Detailed Input and Output Wiring.

3. Operating Instructions

3.1. Display Interface

The T2310 features a 1.37-inch LCD display with two main readings:

  • PV (Process Value): Displays the current time or the first timing parameter (Time1).
  • SV (Set Value): Displays the set time or the second timing parameter (Time2).
  • ON Indicator: A small LED light indicating the relay status (ON/OFF).
T2310 display showing PV and SV values, ON indicator, and four control buttons: UP, SET, DOWN, and STOP/START.

Figure 4: Display Interface and Control Buttons.

3.2. Control Buttons

  • ▲ (UP): Increases the value of the selected parameter.
  • SET: Enters setting mode, switches between parameters, and confirms selections.
  • ▼ (DOWN): Decreases the value of the selected parameter.
  • ⦸ (STOP/START): Starts or stops the timer operation.

3.3. Basic Operation

  1. Power On: The device will automatically start operation based on the last saved settings.
  2. Enter Setting Mode: Long press the SET button for approximately 10 seconds. The display will show a code (e.g., P0, P1, P2) in red digits and its parameter value in green digits.
  3. Navigate Parameters: Press the SET button briefly to cycle through different setting codes (P0, P1, P2, etc.).
  4. Adjust Values: While a parameter code is displayed, use the ▲ (UP) or ▼ (DOWN) buttons to change its value.
  5. Save Settings: After making changes, stop pressing buttons. The device will automatically save the new settings after approximately 10 seconds of inactivity.
  6. Start/Stop Operation: In normal operating mode, press the ⦸ (STOP/START) button to toggle between running and paused states. Double-click ⦸ (STOP/START) to quickly stop/run.
  7. Restart: Long press the ⦸ (STOP/START) button to restart the timer from its initial set values.
  8. Restore Factory Settings: To restore the device to its factory default settings, press and hold the SET button while powering on the device.

3.4. Timing Modes (P-Codes)

The T2310 offers various timing modes configured via P-codes:

  • P0 & P1: Timing Unit Selection
    These parameters are used to set the timing units (seconds, minutes, hours) for PV (Time1) and SV (Time2) respectively. The specific values for these parameters will determine the range and precision of your timer.
  • P2: Cycle Mode Selection
    This parameter defines the operational sequence of the relay.
Diagrams illustrating P2 cycle modes: P2=1 (Relay-ON), P2=2 (Relay-Off then Relay-ON), P2=3 (Relay-ON then Relay-Off), P2=4 (Relay-Off then Relay-ON continuous cycle), P2=5 (Relay-ON then Relay-Off continuous cycle).

Figure 5: P2 Cycle Mode Diagrams.

  • P2=0: Relay-Off (Output remains constantly off).
  • P2=1: Relay-ON (Output remains constantly on).
  • P2=2: Relay-Off then Relay-ON (Single cycle: Relay is off for Time1, then on for Time2, then stops).
  • P2=3: Relay-ON then Relay-Off (Single cycle: Relay is on for Time1, then off for Time2, then stops).
  • P2=4: Relay-Off then Relay-ON (Continuous cycle: Relay is off for Time1, then on for Time2, repeats indefinitely).
  • P2=5: Relay-ON then Relay-Off (Continuous cycle: Relay is on for Time1, then off for Time2, repeats indefinitely).

3.5. Example Application: Rice Transplanter Water Pump Control

Work Requirement: A water pump needs to operate for 10 seconds, then stop for 50 seconds, in a continuous cycle.

Product Selection: Use the 12V version of the T2310, powered by a 12V battery.

Operation Steps:

  1. Enter Setting Mode: From the normal interface, long press the SET button for 10 seconds. The red digits will display the code, and the green digits will display the parameter value.
  2. Set Timing Units: Press SET to navigate to P0. Use ▲ (UP) or ▼ (DOWN) to set P0 to 0 (for seconds). Repeat for P1, setting it to 0 as well.
  3. Set Cycle Mode: Press SET to navigate to P2. Use ▲ (UP) or ▼ (DOWN) to set P2 to 5 (Relay ON then OFF, continuous cycle).
  4. Save Code Settings: After setting P0, P1, and P2, wait for 10 seconds. The device will automatically save these settings.
  5. Set Timing Durations: Return to the normal operating interface. Double-click the SET button. The red digits (PV/Time1) will flash. Use ▲ (UP) or ▼ (DOWN) to adjust the value to 10 (for 10 seconds ON).
  6. Set Second Duration: Single-click the SET button. The green digits (SV/Time2) will flash. Use ▲ (UP) or ▼ (DOWN) to adjust the value to 50 (for 50 seconds OFF).
  7. Save Timing Durations: Wait for 10 seconds. The device will automatically save these settings. The setup is now complete.

All settings are automatically saved even after power loss and will resume operation automatically upon power restoration. No manual start is needed.

Chinese text describing an operation example for a rice transplanter water pump control, detailing steps to set timing parameters.

Figure 6: Example Application Guide (Original).

4. Maintenance

The T2310 Digital Time Controller requires minimal maintenance. Keep the device clean and dry. Avoid exposing it to extreme temperatures, humidity, or corrosive environments. Do not attempt to open the casing as it may void any potential warranty.

5. Troubleshooting

If the device is not functioning as expected, consider the following:

  • No Power/Display: Check the power supply connections and ensure the voltage matches the device's requirements.
  • Incorrect Timing: Verify that the P-codes (P0, P1, P2) and the timing durations (PV, SV) are set correctly according to your desired operation.
  • Relay Not Activating: Ensure the load is correctly wired and functioning. Check the ON indicator on the display.
  • Device Unresponsive: Try restarting the device by long-pressing the STOP/START button. If issues persist, try restoring factory settings (press and hold SET during power-on).

6. Specifications

Table of technical parameters for the T2310 Digital Time Controller, including controller type, operating voltage, relay power, consumption, life, error, weight, size, and fixed way.

Figure 7: Technical Parameters.

ParameterValue
Controller TypeNormally open time controller
Operating VoltageDC 12V / DC 24V / AC110~220V
Control Circuit VoltageDC 12V / DC 24V / AC110~220V
Relay TypeNormally open relay
Relay Carrying Power240W (DC12V) / 480W (DC24V) / 10A (max) (AC110~220V)
Recommended PowerRelay carrying power × 80%
Power Consumption< 1W
Relay Service Life100,000 times
Timing Error±3S (in 24 hours)
Weight65g
Size67mm × 45mm × 34mm
Fixed WayEmbedded (Hole 63mm × 42mm)
CrystalIndependent crystal
Time Error (Crystal)0.002% (24h ± 1.728s)

Certifications: This product has passed CE certification, ensuring compliance with European safety standards.

CE Certificate of Compliance for T2310 Time Controller

Figure 8: CE Certificate of Compliance.

7. User Tips

Based on user feedback, the T2310 Digital Time Controller is considered a very useful and cost-effective device. Here are some tips:

  • It is ideal for automating tasks that require precise on/off timing for electrical loads.
  • The wide timing range (1 second to 999 hours) allows for great flexibility in various applications.
  • Its ability to operate in single-shot, work-pause, and continuous cycle modes makes it adaptable to many scenarios.
  • The power-off memory feature is highly appreciated, as settings are retained even after power interruptions, ensuring consistent operation.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Keep your purchase records for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?