MESTEK SL750/SL750B

Contents

MESTEK SL750/SL750B Digital Sound Level Meter Instruction Manual

Professional Noise Tester & Sonometer

1. Introduction

The MESTEK SL750 and SL750B are high-precision digital sound level meters designed for accurate noise measurement. These multi-functional handheld devices integrate data retention, backlight, maximum value reset, and automatic shutdown features to meet diverse measurement needs. The SL750 model provides A-weighted measurements, while the SL750B offers both A/C-weighted measurements and a color screen.

Comparison of SL750 and SL750B models
Figure 1: Comparison of SL750 and SL750B models, highlighting features like A-weighted vs A/C-weighted, Max/Min measurement, screen backlight, and measurement simulation strip.

2. Product Overview

The MESTEK sound level meter is a robust and user-friendly device. Its ergonomic design with soft rubber material on both sides ensures a comfortable grip for extended use. The device features a capacitive microphone for accurate decibel capture.

Product size and labeled parts diagram
Figure 2: Product size and labeled parts diagram. Dimensions: 206mm (8.11in) height, 53mm (2.08in) width, 34mm (1.33in) thickness. Key components include the sponge ball, microphone, display, data retention, Fast/Slow buttons, Backlight, Maximum value button, and Power switch.

Accessories List

The standard package includes:

  • Noise detector (Host)
  • Instruction manual
  • Packaging box
Accessories list
Figure 3: Accessories list, showing the host device, packaging box, and instruction manual.

3. Setup

3.1 Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Open the cover.
  3. Insert three (3) 1.5V AAA batteries, ensuring correct polarity (+/-). Batteries are not included.
  4. Close the battery compartment cover securely.

3.2 Sponge Ball Protective Cover

The device comes with a sponge ball protective cover. This cover should be placed over the microphone to protect it and ensure the accuracy of test data, especially in environments with wind.

Sponge ball protective cover
Figure 4: Sponge ball protective cover, emphasizing its role in protecting the microphone and ensuring data accuracy within a certain range of wind speeds.

4. Operating Instructions

4.1 Power On/Off

  • Press the Power button (Power button icon) to turn the device on.
  • Press and hold the Power button to turn the device off.
  • The device features automatic shutdown to conserve battery life.

4.2 Measurement Modes (SL750B)

The SL750B model supports both A and C weighting modes:

  • A-weighting: Simulates human auditory perception, suitable for general environmental noise assessment.
  • C-weighting: Measures mechanical noise, suitable for evaluating the noise output of machinery.

To switch between A/C weighting (SL750B only), press the A/C button.

A/C weighting mode explanation
Figure 5: A/C weighting mode explanation, showing A weighting for human auditory perception and C weighting for mechanical noise.

4.3 Fast/Slow Sampling Rate

The device offers adjustable fast and slow time weighting modes:

  • FAST mode: 125ms sampling rate, suitable for capturing sudden or rapidly changing noise levels.
  • SLOW mode: 1000ms sampling rate, suitable for measuring average noise levels over time.

Press the FAST/SLOW button to toggle between these modes.

Adjustable fast/slow time weighting
Figure 6: Adjustable fast/slow time weighting, illustrating 125ms for Fast mode and 1000ms for Slow mode.

4.4 MAX/MIN Measurement (SL750B)

The SL750B model allows for easy switching between maximum and minimum measured values. Press the MIN/MAX button to view the minimum or maximum noise level recorded during a measurement session.

MAX/MIN easy switching feature
Figure 7: MAX/MIN easy switching feature, demonstrating one-click switching between maximum and minimum values.

4.5 Data Retention (HOLD)

To hold the current measurement on the display, press the HOLD button. Press it again to resume live measurement.

4.6 MAX Value Reset

After a measurement, the maximum value can be automatically locked. To reset this value, short press the MAX button.

MAX Zero value reset
Figure 8: MAX Zero value reset, explaining that the maximum value is automatically locked after measurement and can be reset by a short press.

4.7 Screen Backlight

To enable or disable the screen backlight, press the Backlight button (Backlight button icon). This feature allows for measurements in dim environments.

Highlight Screen backlight feature
Figure 9: Highlight Screen backlight feature, showing measurements can be taken in dim environments.

4.8 Display Interpretation

The display provides various indicators and measurement values:

Detailed screen display for SL750B
Figure 10: Detailed screen display for SL750B. Labels include: 1. Automatic shutdown, 2. Fast measurement, 3. Measurement value, 4. Max/min value, 5. Data retention, 6. Battery undervoltage indication, 7. Slow measurement, 8. Measurement simulation strip, 9. A/C measurement unit, 10. Max/min value values.
Detailed screen display for SL750
Figure 11: Detailed screen display for SL750. Labels include: 1. Automatic shutdown, 2. Fast measurement, 3. Measurement value, 4. Maximum value reset, 5. Data retention, 6. Battery undervoltage indication, 7. Slow measurement, 8. A/C measurement unit, 9. Maximum value value.

4.9 Common Noise Range Reference

Refer to the table below for a general understanding of common noise levels:

Common noise range table
Figure 12: Common noise range table (dB) with descriptions: 0-20dB (Very quiet), 20-40dB (Be quiet), 40-60dB (Generally, indoor conversations), 60-70dB (Noisy and nerve damaging), 70-90dB (Very noisy, nerve cells damaged), 90-100dB (Increased noise and hearing loss), 100-120dB (Difficult to tolerate, temporarily causing deafness), >120dB (Extremely deaf or completely deaf).

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Sponge Ball: Regularly check the sponge ball for wear and tear. Replace if damaged to ensure accurate readings and microphone protection.
  • Battery Replacement: Replace batteries when the low battery indicator appears on the display. Always use fresh 1.5V AAA batteries. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Refer to specifications for recommended storage temperature and humidity.

6. Troubleshooting

  • Device does not power on: Check battery installation and ensure batteries are fresh.
  • Inaccurate readings: Ensure the sponge ball is properly installed and not damaged. Avoid measuring in strong winds without the cover. Check for any obstructions to the microphone.
  • Display issues: If the display is dim, activate the backlight. If the display is blank or shows errors, try replacing the batteries.
  • Device freezes: Turn the device off and then on again. If the issue persists, remove and reinsert the batteries.

7. Specifications

ParameterValue
Product NameHigh precision noise detector
ModelSL750 (A-Weighted), SL750B (A/C-Weighted; color screen)
Measurement Range30-130dB
Sampling Rate FAST125ms
Sampling Rate SLOW1000ms
Noise Accuracy±2.0dB
Reference Sound Pressure Standard94dB/1KHz
Frequency Response31.5Hz~8KHz
Resolution0.1dB
Power Supply3x1.5V AAA (not included)
Working Current≤8mA
Working Temperature0-40°C
Working Humidity≤80% RH
Storage Temperature-20~60°C
Storage Humidity≤75% RH
Dimensions206x53x34mm
WeightApproximately 180g (Excluding battery)
Technical parameter table
Figure 13: Technical parameter table for the MESTEK SL750/SL750B Digital Sound Level Meter.

8. User Tips

  • For general environmental noise, use A-weighting. For machinery or industrial noise, consider C-weighting (SL750B).
  • Use the FAST mode for quick, transient noise events and SLOW mode for more stable, average readings.
  • Always ensure the sponge ball is on the microphone to prevent wind noise interference, especially outdoors.
  • The backlight feature is very useful in low-light conditions, but remember to turn it off when not needed to save battery.
  • Regularly check the battery level indicator to avoid interruptions during critical measurements.

9. Warranty and Support

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or service inquiries, please contact your retailer or the manufacturer's customer service. Keep your purchase receipt as proof of purchase.