Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IP68 Waterproof Linear Actuator. Please read all instructions carefully before use to ensure proper function and prevent damage or injury.
Safety & Warnings
Failure to follow these instructions may result in damage to the product or personal injury.
- Moving Parts Hazard: Keep hands, hair, and loose clothing away from the sliding mechanism during operation to prevent crushing or pinching injuries. Disconnect power before making any adjustments.
- Intended Use: This product is designed for professional/industrial use only. Operation by children or unauthorized personnel is strictly prohibited. Not suitable for children under 14 years of age.
- Supervision: To be used under the direct supervision of trained personnel. Read the user manual thoroughly before operation. Improper use may result in serious injury or equipment damage.
- Risk of Electric Shock: Ensure the product is properly grounded (Class 1) before connecting to the power supply. Do not expose to moisture or rain.
- Load Capacity: Do not exceed the maximum rated load capacity. Exceeding the limit may cause instability, loss of control, or mechanical failure. Secure the load before movement.
- Maintenance: Perform regular checks and maintenance of all fixing parts (screws, belts, couplings, etc.). Failure to maintain the equipment may cause failure, leading to falls or product damage.
Setup
Mounting and Pivot Alignment
Ensure both the rear pivot and front rod eye are securely mounted on rigid brackets. The actuator must be aligned with the direction of movement. Side loads or angular misalignment will cause premature wear of the rod bearing and internal components. Use spherical rod ends if angular compensation is needed.
Rod End Attachment
When attaching the rod end to the load, use the provided clevis pin and secure it with a cotter pin or retaining clip. Ensure the attachment point allows free pivoting without binding during movement.
Electrical Connection
Verify the power supply voltage matches the actuator rating (12V DC, 24V DC, 110V AC, etc.). Observe correct polarity for DC models; reversing polarity changes the direction of motion. Ensure the power supply can deliver the required starting current (inrush current).
Cable and Connector Protection
Secure the power cable to avoid tension, sharp bends, or abrasion during actuator movement. Moving cables can be damaged if not properly guided. Use cable carriers if necessary.
Operating Instructions
Initial Test Run
Before installing the actuator under full load, perform a no-load test run through the full stroke. Listen for abnormal noise, check for smooth extension and retraction, and verify that limit switches stop the actuator at the correct positions.
Duty Cycle Consideration
Check the duty cycle rating (e.g., 25% or 10% maximum). Do not run the actuator continuously beyond the specified duty cycle. Allow sufficient cooling time between operations. Overheating the motor will damage the windings and reduce service life.
Load Capacity, Speed, and Smoothness
Never exceed the rated dynamic and static load capacities. Overloading can cause buckling of the push tube, gear failure, or motor burnout. For lifting applications, consider using a brake or anti-backdrive mechanism if specified by the manufacturer.
Actuator speed is load-dependent. Under heavy load, the speed may drop. Ensure the load is applied smoothly and without shock. Sudden impact loads can damage the lead screw and nut assembly.
Limit Switches and Overload Protection
Most actuators are equipped with built-in limit switches to stop the motor at the end of stroke. Do not rely on mechanical stalling to stop the actuator, as this will damage the gearbox and motor. Install external limit switches or use the built-in ones correctly. If the actuator has an overload clutch, test it periodically to ensure proper function.
The push rod has overcurrent, short circuit, overload, and overvoltage protection, and can automatically stop to prevent damage.
Maintenance
Periodic Inspection
Regularly inspect the actuator for signs of wear, leakage of lubricant, or damage to the push tube surface. Keep the rod surface clean and free of debris. Wipe off any dirt or moisture after use in harsh environments.
Storage
If storing the actuator before installation, retract the rod fully to protect it from damage and contamination. Store indoors in a dry, clean environment. Extend and retract periodically if stored for long periods to prevent internal corrosion.
Troubleshooting
- Actuator stops unexpectedly: This may indicate overcurrent, short circuit, overload, or overvoltage protection has been triggered. Check the load and power supply.
- Movement is not smooth or actuator binds: Verify proper mounting and alignment. Ensure there are no side loads or angular misalignment. Spherical rod ends may be needed for angular compensation.
- Motor overheats: Check the duty cycle rating and ensure the actuator is not run continuously beyond its specified duty cycle. Allow sufficient cooling time between operations.
- Actuator does not move: Check electrical connections, ensure correct voltage and polarity (for DC models), and confirm the power supply can deliver the required starting current.
Specifications
| Feature | Specification |
|---|---|
| Voltage | DC 12V / 24V (Customizable 36V / 48V) |
| Stroke (S) | 50mm - 1200mm |
| Maximum Thrust | 1200N |
| Maximum Self-locking Force | 12000N |
| Speed | 3mm/s - 40mm/s |
| Working Temperature | -20℃ to 65℃ |
| Material | Aluminum alloy shell and expansion tube (customizable stainless steel expansion tube) |
| Protection Level | IP68 (Can be placed underwater within one meter) |
| Working Frequency | 20% |
| High Speed Operating Frequency | 10% |
| Maximum Working Life | 30000 cycles |
| Features | Built-in micro switch, sturdy and durable, overcurrent/overload protection. |
| Minimum Installation Distance (L) | Stroke (S) + 105mm (when fully retracted) |
| Maximum Installation Distance | Center distance between front and rear mounting holes after push rod is fully extended. Output length = 105mm + S. |
| Certification | CE |
| Origin | Mainland China |
User Tips
- The IP68 rating indicates strong water resistance, making this actuator suitable for applications in wet or marine environments. However, ensure it is not continuously immersed beyond one meter depth.
- Always verify the required load capacity (Thrust) and speed (mm/s) for your specific application against the product specifications to ensure optimal performance and prevent damage.
- For applications requiring precise positioning or where the actuator might be exposed to varying loads, consider using external limit switches for enhanced control and safety.
Warranty & Support
For product quality or infringement issues, the manufacturer/importer/seller shall be solely held responsible. AliExpress acts as an EU representative for cross-border sellers and is not involved in the manufacture, import, or sale of the product, and therefore is not responsible for after-sales services.
Manufacturer Information:
- Manufacturer: SUMTOR(WUXI) ELECTRIC CO.,LTD
- Address: No.118-1 Liangdong Road, Wuxi city, Jiangsu Province, 214000 China
- Phone Number: +86 15768369406
- Email: 13802221171@163.com
- Website: http://www.sumtor.com/
EU Authorized Representative:
- Representative: SUCCESS COURIER SL
- Address: CALLE RIO TORMES NUM. 1, PLANTA 1, DERECHA, OFICINA 3, Fuenlabrada, Madrid, 28947 Spain
- Phone Number: +34910602659
- Email: successservice2@hotmail.com
Note: This product must comply with all applicable safety and regulatory requirements in the market where it is sold. Sellers must assess which requirements and regulations apply based on the actual product type, function, and destination market.