yieryi BLE-C600/BLE-9909

Contents

User Manual for yieryi Bluetooth Water Quality Tester

Models: BLE-C600 (7-in-1) & BLE-9909 (5-in-1)

1. Introduction

This manual provides detailed instructions for the operation, calibration, and maintenance of your yieryi Bluetooth Water Quality Tester. This device is available in two models:

  • BLE-C600 (7-in-1): Measures pH, EC, TDS, ORP, SALT, S.G, and Temperature.
  • BLE-9909 (5-in-1): Measures pH, TDS, EC, SALT, S.G, and Temperature.

These smart meters are designed for professional measurement of various water quality parameters with data synchronization to a mobile application. They are suitable for a wide range of applications such as drinking water, aquariums, fish tanks, swimming pools, hydroponics, farmland irrigation, and laboratory use.

2. Safety Precautions

  • Always handle the electrode with care.
  • Clean the electrode with distilled water before and after each use.
  • Do not attempt to self-assemble or modify the device, as this may cause damage and void the warranty.
  • Keep the device away from extreme temperatures and direct sunlight.
  • Ensure the protective cap is on the electrode when not in use to keep it moist.

3. Package Contents

Please check the package for the following items:

  • 1 x yieryi Bluetooth Water Quality Tester (BLE-C600 or BLE-9909)
  • pH Buffer Powders (e.g., pH 4.00, pH 6.86, pH 7.00, pH 9.18, pH 10.01)
  • Instruction Manual (this document)
  • Batteries (3*1.5V LR44) - Note: Batteries may not be included if shipped from China due to shipping regulations. Please purchase locally if needed.

4. Product Overview

The yieryi Bluetooth Water Quality Tester features a high-definition LCD display and intuitive buttons for easy operation. It connects to a mobile app for advanced data management and real-time monitoring.

4.1 Device Components

  • HD LCD Display: Shows measurement readings.
  • Buttons:
    • ON/OFF: Power on/off.
    • HOLD/TEMP: Hold reading / Switch temperature unit (°C/°F).
    • MODE/CAL: Switch measurement mode (pH, EC, TDS, ORP, SALT, S.G) / Enter calibration mode.
    • Up/Down Arrows: Adjust digits during calibration.
  • Immersion Line: Indicates the minimum immersion depth for accurate readings.
  • Protective Cap: Covers the electrode to keep it moist.
BLE-C600 7-in-1 meter with app display and pH buffer powders
Figure 1: BLE-C600 7-in-1 Water Quality Tester with Mobile App Interface
BLE-9909 5-in-1 meter with app display and pH buffer powders
Figure 2: BLE-9909 5-in-1 Water Quality Tester with Mobile App Interface

5. Specifications

5.1 General Specifications (Applicable to both BLE-C600 and BLE-9909)

  • Display Type: DIGITAL, with Backlight
  • Is Smart Device: Yes (Bluetooth connectivity)
  • Battery: 3*1.5V LR44
  • Waterproof Grade: IP67
  • Work Environment: 0.1℃-80.0℃; RH: max 90%
  • Dimensions: 187mm * 37mm * 37mm (7.36in * 1.46in * 1.46in)
  • Weight: 95g
  • Certification: CE
  • Origin: Mainland China

5.2 Measurement Parameters and Ranges

ParameterRangeResolutionAccuracyModel
pH0.00-14.00 pH0.01 pH±0.05 pHBoth
EC0-9990µS/cm; 10.01-19.90 mS/cm; 20.1-200.0 mS/cm1µS/cm; 0.01mS/cm; 0.1mS/cm±2% F.SBoth
TDS0-9990ppm; 10.1-100.0 ppt1 ppm; 10ppm; 0.1ppt±2% F.S.Both
SALT0.01-15.00%; 0-999 ppm; 1000-9990ppm; 10.1-150.0 ppt0.01%; 1ppm; 10ppm; 0.1ppt±2% F.S.Both
S.G1.000-1.222--Both
ORP-1200mV - +1200mV1mV±0.5℃BLE-C600 only
Temperature0.1℃-60.0℃; 32.1℉-140.0℉0.1℃; 0.1℉±0.5℃Both

*F.S. = Full Scale

BLE-C600 ORP value and application table
Figure 3: ORP Value and Application for BLE-C600
BLE-C600 TDS value and numerical reference table
Figure 4: TDS Value and Numerical Reference Table for BLE-C600
BLE-C600 EC water conductivity table
Figure 5: EC Water Conductivity Reference for BLE-C600
BLE-C600/BLE-9909 salt measurement and applications
Figure 6: Salt Measurement and Applications

6. Setup

6.1 Battery Installation

The device requires 3*1.5V LR44 batteries. To install or replace batteries:

  1. Unscrew the battery compartment cover.
  2. Insert the LR44 batteries, ensuring correct polarity.
  3. Securely close the battery compartment.

6.2 Mobile App Download

To utilize the smart features, download the "YINMIK" mobile application:

  1. Scan the appropriate QR code below with your smartphone.
  2. Download and install the "YINMIK" app for your operating system (iOS or Android).
QR codes for Android and iOS apps
Figure 7: QR Codes for YINMIK Mobile App (Android and iOS)

7. Operation

7.1 Power On/Off

  • Press the "ON/OFF" button to turn the meter on.
  • Long press the "ON/OFF" button for 5 seconds to turn off the Bluetooth function (if enabled) or to power off the device.

7.2 Bluetooth Connection

  1. Ensure the meter is powered on and the Bluetooth logo is displayed on the screen (if not, long press "ON/OFF" for 5 seconds until it appears).
  2. Open the "YINMIK" app on your smartphone.
  3. The app will automatically search for and match the meter model.

7.3 Taking Measurements

  1. Remove the protective cap from the electrode.
  2. Immerse the electrode into the testing solution, ensuring the immersion line is covered.
  3. Wait until the reading on the display stabilizes.
  4. Press the "MODE/CAL" button to cycle through different measurement modes (pH, EC, TDS, Salinity, ORP, S.G).
  5. To hold the current reading, press the "HOLD/TEMP" button. Press again to release.
  6. To switch the temperature unit between °C and °F, long press the "HOLD/TEMP" button.
BLE-C600 data synchronization display
Figure 8: Data Synchronization Display (BLE-C600 example)
BLE-9909 mobile APP intelligent control
Figure 9: Mobile App Intelligent Control (BLE-9909 example)

8. Calibration

Regular calibration ensures the accuracy of your meter. The meter supports two sets of calibration points: 6.86/4.00/9.18 (Asia Standard) and 7.00/4.00/10.01 (EU Standard). You can select the standard in the app settings.

Video 1: pH Calibration Process

8.1 pH Calibration (6.86/4.00/9.18 or 7.00/4.00/10.01)

Prepare three cups, each filled with 250ml of distilled water. Dissolve one pH buffer powder (e.g., 4.00, 6.86, 9.18) into each cup to create the standard solutions.

  1. Calibrating 4.00 pH:
    • Put the electrode into the 4.00 pH standard solution.
    • Wait until the testing is stabilized.
    • Press the "MODE/CAL" button for 5 seconds. The screen will display "CAL" and then "4.00".
    • Wait for "4.00" to flash 3 times. The 4.00 calibration is complete.
    • Clean the electrode with distilled water.
  2. Calibrating 6.86 pH:
    • Put the electrode into the 6.86 pH standard solution.
    • Wait until the testing is stabilized.
    • Press the "MODE/CAL" button for 5 seconds. The screen will display "CAL" and then "6.86".
    • Wait for "6.86" to flash 3 times. The 6.86 calibration is complete.
    • Clean the electrode with distilled water.
  3. Calibrating 9.18 pH:
    • Put the electrode into the 9.18 pH standard solution.
    • Wait until the testing is stabilized.
    • Press the "MODE/CAL" button for 5 seconds. The screen will display "CAL" and then "9.18".
    • Wait for "9.18" to flash 3 times. The 9.18 calibration is complete.
    • Clean the electrode with distilled water.

The calibration procedure for 7.00/4.00/10.01 pH buffer solutions is the same.

BLE-C600 pH scale and applications
Figure 10: pH Scale and Applications

8.2 ORP Calibration (256mV)

  1. Press the "MODE/CAL" button to convert to ORP Mode.
  2. Put the electrode into the 256mV standard solution. Wait for the value to stabilize.
  3. Press "MODE/CAL" for 5 seconds, then release.
  4. Use the Up arrow (HOLD/TEMP) to add digits or Down arrow (MODE/CAL) to reduce digits until the displayed value is 256. Release the button.
  5. Wait for "256" to flash 3 times. The ORP calibration is complete.
  6. Clean the electrode with distilled water.

8.3 TDS/EC/SALT Calibration (1413µS/cm or 12.88mS/cm or 111.8mS/cm)

Choose a standard solution that is close to your expected test solution for EC calibration.

  1. Press the "MODE/CAL" button to convert to EC Mode.
  2. Put the electrode into the chosen standard solution (e.g., 1413µS/cm). Wait until the testing is stabilized.
  3. Press "MODE/CAL" for 5 seconds, then release. The screen will display the value.
  4. Use the Up arrow (HOLD/TEMP) to add digits or Down arrow (MODE/CAL) to reduce digits until the displayed value matches the standard solution (e.g., 1413). Release the button.
  5. Wait for the value to flash 3 times. The calibration is complete.
  6. Clean the electrode with distilled water.

9. Data Management (via Mobile App)

The YINMIK app provides comprehensive data management features:

  • Real-time Display: All testing results (mV/S.G/ppm/%/pH/µS/cm/°C/°F) can be viewed on the app.
  • Manual Saving: Click "Save Reading" in the app to manually save current measurement data. Manually saved data is displayed in black.
  • Automatic Saving: The app can be configured to automatically save data at set intervals (between 30-9999 seconds). Automatically saved data is displayed in blue.
  • Viewing Records: Press the "Saved" tab in the app to view measurement data records.
  • Sharing and Printing: Saved data can be exported to Excel and shared with others. If connected to a printer, testing records can be printed.
  • Limit Values: Set maximum or minimum limit values for pH/EC/ORP. If a test result exceeds the set range, the digits will display in red on the app.
  • EC Temperature Compensation: The EC Temp. factor (default 2.0%/℃) can be adjusted between 0.1~3.0%/℃ in the app settings.
BLE-C600 with app showing data synchronization
Figure 11: App Data Synchronization and Display
BLE-C600 with app showing data synchronization
Figure 12: App Data Saving and Limit Settings

10. Maintenance

  • Electrode Cleaning: Always clean the electrode with distilled water before and after each measurement and calibration.
  • Storage: When not in use, ensure the protective cap is securely placed on the electrode to keep it moist. Store the meter in a cool, dry place.
  • Battery Replacement: Replace batteries when the low battery indicator appears on the display or in the app.

11. Troubleshooting

ProblemPossible CauseSolution
Cannot connect to BluetoothBluetooth function not activated on meter or phone; App not recognizing device.
  1. Ensure the meter is powered on.
  2. Long press the "ON/OFF" button for 5 seconds until the Bluetooth logo appears on the meter's screen.
  3. Ensure Bluetooth is enabled on your smartphone.
  4. Open the "YINMIK" app and allow it to search for the device.
  5. If issues persist, try restarting both the meter and your phone.
Inaccurate readings / Large errorMeter needs calibration; Electrode is dirty or damaged.
  1. Perform a full calibration for the relevant parameter (pH, EC, TDS, ORP, SALT).
  2. Clean the electrode thoroughly with distilled water.
  3. If the electrode is damaged, it may need replacement.
ORP measurement not working properlyCalibration issue or sensor fault.
  1. Ensure proper ORP calibration using a 256mV standard solution.
  2. Compare readings with a known accurate ORP meter if available.
  3. If the issue persists after calibration, the sensor may be faulty.

12. User Tips

  • Bluetooth Pairing: If you encounter difficulty pairing via Bluetooth, try restarting both the meter and your phone. Sometimes multiple attempts are needed for a successful connection.
  • Calibration Frequency: The product is factory-calibrated. Recalibration is generally only needed if you observe significant discrepancies in readings (e.g., tap water pH not between 7-8) or after prolonged use.
  • Battery Availability: LR44 batteries are commonly available in local stores if your package did not include them.

13. Warranty and Support

13.1 Warranty Information

  • Meter Warranty Time: 12 months
  • Electrode Warranty Time: 6 months

During the warranty period, the meter will be repaired or replaced free of charge due to damage caused by the meter's quality.

The following are not covered by the warranty:

  1. Damage by wrong use or self-assembly.
  2. Damage by human factors.
  3. Damage by force majeure.

13.2 Customer Support

If you encounter any quality problems or require technical assistance, please contact customer service immediately. If a quality problem is identified within one week of receiving the product, free return and replacement may be provided.

For replacement probes or other parts, please contact customer support for availability and purchasing options.

14. Frequently Asked Questions (FAQ)

Q: Does the product include batteries? What is the battery number?
A: Products shipped from overseas warehouses (e.g., Russia) may include batteries. If shipped from China, batteries will typically be removed due to shipping regulations. The battery model is LR44, which can be purchased from local stores.
Q: When will this device need to be recalibrated?
A: The product is factory-calibrated. Recalibration is generally needed if you find a large error in measurements. For example, if the pH of measured tap water is not typically between 7-8, then correction might be needed.
Q: What if a quality problem is found?
A: Please contact customer service immediately and explain the problem. If a quality problem is found within one week after receiving the product, free return and replacement of the product will be provided.
Q: Does the sensor tip include a cap to keep the pH sensor moist?
A: Yes, the electrode comes with a protective cap designed to keep the pH sensor moist, which is crucial for its longevity and accuracy.
Q: Where can I get a replacement probe?
A: Please contact customer support for information on purchasing replacement probes.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.