The Aquastrong EKM60-1 Peripheral Water Pump is designed for efficient and high-pressure water transfer in domestic supply systems and small buildings. It offers superior performance even with low water volume, making it ideal for low-pressure pressurization and small-scale irrigation. This manual provides essential information for the safe and effective installation, operation, and maintenance of your pump.

Main Applications:
- Supply of Water Boxes: Ideal for homes and small buildings.
- Small Irrigations: Perfect for small gardens and vegetable gardens.
2. Safety Information
WARNING: Read all safety warnings and instructions carefully before installing or operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Always ensure the pump is disconnected from the power supply before performing any installation, maintenance, or repair work.
- The pump must be installed by a qualified professional in accordance with local electrical and plumbing codes.
- Protect the pump from moisture and direct exposure to rain.
- Do not operate the pump with damaged cables or plugs.
- Ensure the pump is properly grounded.
- Never run the pump dry. Operating without water can cause severe damage to the pump.
- Keep children and unauthorized persons away from the pump during operation.

ATTENTION: Choose the correct voltage for your equipment at the time of purchase. The equipment does not exchange for misuse due to incorrect voltage selection.
3. Specifications
The EKM60-1 Peripheral Water Pump is engineered with robust materials and features to ensure reliable performance.
Technical Features:
- Body: Cast Iron with anti-rust treatment.
- Antilock System: Ensures continuous and reliable operation.
- Shaft: Stainless Steel, resistant and durable.
- Maximum Liquid Temperature: 40 °C.
- Mechanical Seal: Graphite/Ceramic, offering efficiency and resistance.
- Rotor: Bronze Peripheral, for high pressure and reliable performance.
- Capacity (Model EKM60): Up to 30 MCA (meters of column of water) and 2.1 m³/h.
Engine Features:
- Power: 0.5 HP.
- Thermal Protector: Built-in, protects the motor against overload.
- Degree of Protection: IPX4, resistant to splashes of water.
- Insulation Class: F, for high resistance to heat.
- Maximum Ambient Temperature: 40 °C.
Electrical Specifications:
- Voltage Options: Bivolt model (127/220 VAC), 127 VCA model, 220 VCA model.
Dimensions and Weight:

- Height: 174 mm
- Width: 283 mm
- Length: 158 mm
- Weight: 5.2 kg
Performance Curve:

The graph illustrates the relationship between pressure (mca) and flow rate (m³/h) for the EKM60 model. The table provides detailed technical data including voltage, suction/recalque, power (kW/HP), and total manometric head (MCA) at various flow rates for both EKM60-1 and EKM80-1 models.
| Model | Voltage (V) | Suction/Recalque | Power (kW) | Power (HP) | Total Manometric Head (MCA) at 0 m³/h | Diameter of Seal (mm) |
|---|---|---|---|---|---|---|
| EKM60-1 | 110/220 (M) | 1"x1" | 0.37 | 0.5 | 35 | 12 |
| EKM60-1 | 110 or 220 | 1"x1" | 0.37 | 0.5 | 35 | 12 |
*Note: The table in Figure 4 provides more detailed flow rate vs. MCA values. The values above are a summary.
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your EKM60-1 pump. Always refer to local codes and consult a qualified professional if unsure.
4.1 Site Selection:
- Choose a dry, well-ventilated location, protected from direct sunlight, rain, and freezing temperatures.
- Ensure the pump is placed on a stable, level surface to minimize vibration.
- Allow sufficient space around the pump for ventilation and maintenance access.
4.2 Electrical Connection:
- Verify Voltage: Before connecting, confirm that the pump's voltage matches your power supply (127V or 220V). Refer to the warning in Section 2.
- Ensure the electrical circuit is equipped with appropriate overcurrent protection (e.g., circuit breaker or fuse) and a residual current device (RCD) for safety.
- The pump must be properly grounded to prevent electric shock.
4.3 Plumbing Connections:
- Use appropriate pipe sizes for suction and discharge to ensure optimal performance and prevent cavitation.
- Ensure all connections are airtight to prevent air leaks, especially on the suction side.
- Install a non-return valve (check valve) on the suction line if the water source is below the pump level to prevent water from flowing back and to maintain prime.
- Foot Valve: If the motor pump is not submerged (i.e., drawing water from a lower level), it is necessary to install a foot valve at the end of the suction pipe in the water source. This helps maintain prime and filters out large debris.
- Install shut-off valves on both suction and discharge lines to facilitate maintenance.
4.4 Priming the Pump:
Before initial operation, the pump must be primed to ensure it is filled with water and can create suction.
- Ensure all plumbing connections are secure and airtight.
- Open the priming plug (usually located on the top of the pump casing).
- Slowly fill the pump casing and the suction line with water until no more air bubbles emerge.
- Replace and tighten the priming plug.
- Open any discharge valves to allow water flow.
5. Operating Instructions
5.1 Starting the Pump:
- Ensure the pump has been properly primed (see Section 4.4).
- Verify that all valves in the suction and discharge lines are open as required for operation.
- Connect the pump to the power supply. The pump should start immediately.
- Observe the pump for any unusual noises or vibrations. If any occur, disconnect power immediately and investigate.
5.2 Stopping the Pump:
- If equipped with a switch, turn off the pump.
- Disconnect the pump from the power supply for extended periods of non-use or before any maintenance.
5.3 Important Operating Notes:
- Never run the pump dry. This will cause severe damage to the mechanical seal and other internal components.
- Monitor the pump's performance regularly. A decrease in flow or pressure may indicate a problem.
- The built-in thermal protector will automatically shut off the pump if the motor overheats. If this occurs, disconnect power, allow the pump to cool down, and investigate the cause of overheating (e.g., low voltage, blocked impeller, running dry).
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your EKM60-1 pump.
- Regular Inspection: Periodically check the pump for any signs of leaks, corrosion, or damage to cables and connections.
- Cleanliness: Keep the pump exterior clean and free from dust and debris to ensure proper motor cooling.
- Winterization (if applicable): If the pump is exposed to freezing temperatures, drain all water from the pump and pipes to prevent damage from ice expansion. Store the pump in a dry, frost-free location.
- Shaft and Seal: The stainless steel shaft and graphite/ceramic mechanical seal are designed for durability. If leaks occur around the shaft, the mechanical seal may need replacement by a qualified technician.
- Antilock System: The pump features an antilock system for continuous operation. However, if the pump seizes, it may indicate a blockage or internal issue requiring professional inspection.
Always disconnect the pump from the power supply before performing any maintenance.
7. Troubleshooting
This section provides solutions to common problems you might encounter with your EKM60-1 pump. For issues not listed or if problems persist, contact a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power supply Incorrect voltage Thermal overload tripped Motor seized | Check power connection and circuit breaker Verify correct voltage selection Allow motor to cool; check for cause of overload Inspect for blockages or internal damage |
| Pump runs but no water flows | Pump not primed Air leak in suction line Suction line blocked Foot valve stuck/blocked Impeller damaged | Re-prime the pump Check all suction connections for leaks Clear any blockages in the suction line Inspect and clean foot valve Inspect impeller for damage (professional service) |
| Low flow or pressure | Partial blockage in suction/discharge Air leak in suction line Pump not fully primed Worn impeller/components | Check and clear blockages Check suction connections Re-prime the pump Professional inspection and repair |
| Excessive noise or vibration | Cavitation (air in pump) Loose mounting Bearing wear Foreign object in pump | Ensure pump is primed and no air leaks Tighten mounting bolts Professional inspection Disconnect power and inspect impeller area |
8. User Tips
No specific user tips were available from reviews or Q&A for this product. However, general tips for peripheral pumps include:
- Always ensure the pump is adequately supplied with water to prevent dry running.
- For optimal performance, keep the suction line as short and straight as possible.
- Consider installing a pressure gauge on the discharge side to monitor pump performance.