1. Safety Instructions
Please read all safety instructions carefully before installation and use.
- Warning: The charging station must be grounded (PE) in order to use it properly.
- Warning: Do not place flammable, explosive or combustible materials, chemicals, combustible vapors or other hazardous materials near the charging station.
- Warning: Keep the charging plug head clean and dry. If dirty, wipe it with a clean and dry cloth. It is strictly forbidden to touch the charging plug core by hand when it is charged.
- Warning: It is strictly forbidden to use the charging station when the charging plug or charging cable is defective, cracked, worn, broken, or when the charging cable is exposed.
- Warning: Do not attempt to disassemble, repair or modify the charging station. If you need to repair or modify it, please contact the relevant staff. Improper operation may cause damage, water leakage, electrical leakage, short circuit, electric shock, and other risks.
- Warning: Use with caution during thunderstorms.
- Warning: Children should not approach or use the charging station during the charging process to avoid electric shock.
- Warning: Do not drive the car while it is charging. You can only start charging when the car is stationary. For hybrid cars, please turn off the engine before charging.
- Warning: In case of emergency during the operation of the product, press the emergency stop button immediately to cut off all input and output power.
- Warning: The use of the charging post is prohibited in the following cases and the manufacturer should be contacted immediately:
- Charging Station shell is broken.
- When the charging cable on the charging station is damaged, cracked, frayed, broken, etc.
- Lightning strikes charging station.
- Accidents or fires near charging stations.
- Water in the charging station.
- The length of the charging cable on charging station is not long enough to connect to the car, an extension cable needs to be installed.
2. Product Overview
The Feyree EV Charger is designed for electric vehicle AC charging, offering a simple design with multiple specifications (Type2, Type1, GB/T, TS-NACS). It supports swipe card and plug-and-play charging methods, along with various safety protection functions. The unit is dustproof and waterproof (IP65/IP66 rated), making it suitable for outdoor use.
Main Features:
- Dynamic Load Balancing (DLB): Integrates into your home electrical system to reduce peaks in energy usage by intelligently adjusting power output based on household energy consumption. A sensor installed on the main circuit measures real-time total current data.
- Smart and Intelligent EV Charger: Features a 4.3-inch LCD screen to monitor voltage, current, and charging time during the charging process.
- Newly Upgraded APP: Monitor 12 months of charging history (duration, power consumption, date), control and monitor charging remotely, set current, and schedule charging times.
- Calendar Settings: Time and date can be synchronized via Wi-Fi or set manually without a network.
- Money Saving Mode: Supports scheduling charging times during off-peak hours.
- Charging Log Intelligent Management: Check recent 500 charging log details.
- Charging Fault Log Records: Records up to 100 recent charging faults (time, error codes) for quick troubleshooting.
- Safety Type B Leakage Protection: Equipped with Type B AC30mA + DC6mA leakage protection.
- Faster Charging Speed: Available in 7kW, 11kW, and 22kW models.
- Convenient WiFi Connectivity: Control and monitor via Tuya Smart App.
- Multiple Protection: Provides lightning-proof, leakage, overvoltage, overheat, IP65 waterproof, UL94V-0 flame resistance, and overcurrent protection.
- Flexible Current Adjustment: 8A/10A/13A/16A/20A/25A/32A adjustable for 7kW/22kW versions; 8A/10A/13A/16A adjustable for 11kW version.
3. Specifications
General Specifications:
- Brand Name: Feyree
- Origin: Mainland China
- Charger Type: Charging Station
- Type: Type 2
- Charger Version: with Dynamic Load Balancing
- Screen Size: 4.3 inch
- Wireless Support: Wifi
- Touchscreen: No
- Material: Copper alloy, silver plating
- IP Rating: IP65
- Operating Temperature: -30°C to 55°C
- Input Frequency: 50Hz-60Hz
- RCD: TypeB AC 30mA + DC 6mA
- FCC ID: 2BALN-OBZ10-AC-3P32
Model-Specific Parameters (Type 2 IEC61851):
| Feature | 7.6kW | 11kW | 22kW |
|---|---|---|---|
| Power Rating | 7.6kW | 11kW | 22kW |
| Load balancing | Yes | Yes | Yes |
| APP | Yes | Yes | Yes |
| RFID Card | Yes | Yes | Yes |
| Type B RCD | Yes | Yes | Yes |
| Power supply system | Single Phase | Three Phase | Three Phase |
| Rated voltage | 85V-264V | 380V±20% | 380V±20% |
| Rated current | 8-10-13-16-20-25-32A | 8-10-13-16A | 8-10-13-16-20-25-32A |
| Input Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
| Charger Plug | IP65 | IP65 | IP65 |
| Charger Box | IP66 | IP66 | IP66 |
| Working temperature | -35°C ~ +55°C | -35°C ~ +55°C | -35°C ~ +55°C |
| Storage temperature | -40°C ~ +80°C | -40°C ~ +80°C | -40°C ~ +80°C |
| Standby power | <3W | <3W | <3W |
| Working humidity | 5%~95% non-condensation | 5%~95% non-condensation | 5%~95% non-condensation |
| Cable Specification | 3G 6mm² + 1*0.5mm² | 5G 2.5mm² + 1*0.5mm² | 5G 6mm² + 1*0.5mm² |
Note: Similar parameter tables are available for Type 1 SAE J1772, GB/T, and TS-NACS models in the full PDF manual.
For a complete list of specifications and other model types, please refer to the official user manual PDF: Feyree EV Charging Station Manual (PDF).
4. Installation
4.1. Pre-use Preparation
- Ensure there are no open flames around the equipment and that the surrounding space is not blocked.
- Ensure the equipment casing and charging cable are not damaged.
- Ensure proper maintenance of equipment.
- Make sure the emergency stop button is popped up. If it has been pressed, rotate the button clockwise to turn it back.
4.2. Package Contents
Video: Unboxing the Feyree EV Charger and its components.
4.3. Mounting the Charger
- Step 1: According to the position of the holes on the metal back mounting bracket, use an electric drill to drill holes in the corresponding positions on the wall. Refer to the provided diagram for recommended installation height (e.g., 1100mm from ground to top, 1280mm from ground to top, 800mm from ground to bottom of charger). Insert expansion tubes into the holes, then use long screws to fix the metal mounting bracket to the wall.
- Step 2: After fixing the metal bracket to the wall, hang the charger on the bracket. Use additional screws to fix the metal bracket underneath the charger to the wall for added security.
- Step 3: Install the charging plug holder in the desired position on the wall.
- Step 4: Connect the power supply and ensure the charger works properly.
4.4. Wiring Diagrams
Proper wiring is crucial for safe and efficient operation. Consult a qualified electrician for installation if you are unsure.
5. Operation
5.1. Charging Steps
- Standby Status: When in standby mode, the interface displays that the device is ready for charging. The indicator light on the wallbox will be green and always on.
- Waiting for Card Swipe Status: After parking your car, take the charging plug from the holder, set the desired charging current (if needed), then insert the charging plug into the electric vehicle's connector. Ensure the plug is securely inserted. The device will then enter identity verification status.
- Start-up Device: Use an RFID card to authorize the charging station. Tap the RFID card on the induction area.
- Start Charging: Once authorized, the device will begin charging, and the interface will display the charging status and information parameters. The indicator light (for Wi-Fi function only) will be green and breathing or always on.
- Stop Charging:
- The charging station will automatically stop charging when the vehicle is fully charged.
- In case of emergency, press the Emergency Stop button to cut off power.
- An RFID card can also be used to authorize stopping the charging process.
5.2. Key Operation Instructions
- How to Set the Charging Current: When the charging plug is not inserted, press button 'A' on the panel to adjust the charging current. After using the RFID card to turn on charging, the device will output the corresponding current. The current setting range is 8-32A for 7.6kW and 22kW versions, and 8-16A for 11kW versions.
- How to Set Time Delay Charging: When the charging plug is not inserted, touch the 'D' button to set the delayed charging time (0-15 hours). The charger will start charging after the set delay.
- How to Set the Timing Charging: When the charging plug is not inserted, touch the 'T' button to modify the timing charging duration (0-15 hours). The charger will keep charging for the set duration and then stop.
5.3. Menu Navigation
To access the settings menu:
- For models without RFID function: Long press the indicated area on the display for 5 seconds.
- For models with RFID function: Long press the indicated area for 5 seconds, then swipe the RFID card.
Use the panel icons for upward/downward shifts, enter, and back functions. Note: The charging plug must be unplugged to access charging plan and load balance settings.
5.4. Dynamic Load Balancing (DLB)
DLB charging stations are intelligent systems that dynamically sense the household's total circuit load. They prioritize the charging station's power output relative to household appliance consumption by monitoring the total circuit load in real-time. This is an adaptive power adjustment system to protect household electrical safety.
- Total Current: Maximum current capacity per phase (e.g., 80A) for the home circuit, adjustable from 13A to 99A. Exceeding this trips the breaker.
- CT Sensor: Monitors real-time total current data of all household electrical devices.
- Charging Current: Real-time current when the charger is working.
- Home Appliance: Total load of home appliances excluding the charging station.
- Standby Current: Total Current - CT Sensor.
5.5. App Usage
The device requires Wi-Fi and Bluetooth functions for app connectivity.
- Download the "Smart Life" (recommended) or "Tuya Smart" app from your mobile phone's app store.
- Open the app, turn on your phone's Wi-Fi and Bluetooth. Select "Add Device" and follow the on-screen instructions to complete the device addition.
6. Control Box LCD Display
6.1. Single-phase Interface
6.2. Three-phase Interface
7. Troubleshooting
| Fault Name | Reason for Failure | Recommendations |
|---|---|---|
| Over Voltage | AC input voltage is too high |
|
| Under Voltage | AC input voltage is too low |
|
| Over Current | AC input current is too high |
|
| Over TEMP | Charger internal temperature > 85°C |
|
| Elec Leakage | Leakage > specified values (TypeA: 20/30mA, TypeB: 6mA) |
|
| Leakage self check | Sensor for detecting leakage is abnormal |
|
| PE Fault | Poor grounding or incorrect wiring |
|
| Err:cp | Charging plug CC/CP connection abnormality |
|
| Err:Reset | Reset button is pressed |
|
| Err:LoadBalance | Standby current + charging current < 8A |
|
8. Charging Status and Indicator Light
| Charging Status | Green Light | Blue Light | Red Light | Description |
|---|---|---|---|---|
| Ready | Ever-bright | / | / | Power-up for self-test or reset |
| Connect | Flashing | / | / | Detection point 1 voltage is 9 ± 0.8 V. |
| Charging | / | Breathing | / | Detection point 1 voltage is 6 ± 0.8 V, relay closed |
| Finish | / | Ever-bright | / | Charging finished |
| Err:CP | / | / | Flash 1 time (0.5S) | Detection point 1 voltage is 9.8V<U<11.2V; 6.8V<U<8.2V; 12.8V<U or U<5.2V; relay opened |
| Under Voltage | / | / | Flash 2 time (0.5S) | Single-phase: voltage <85V, Three-phase: <304V |
| Over Voltage | / | / | Flash 3 time (0.5S) | Single-phase: voltage > 264V, Three-phase: > 457V |
| Elec Leakage | / | / | Flash 4 time (0.5S) | Relay is opened, it will be closed if re-powered after troubleshooting. |
| Over Current | / | / | Flash 5 time (0.5S) | The line current keeps at Ie+2<I≤Ie+4 for 5 seconds, the relay is opened, then restarted automatically after 10 seconds. It will permanently disconnect after three repetitions. At I> Ie+4, the relay is disconnected and the charging is finished. |
| Over Temp | / | / | Flash 6 time (0.5S) | Temperature > 85°C, the relay is opened. When the temperature is < 65°C, charging restarts. |
| Err:Reset | / | / | Flash 7 time (0.5S) | Emergency stop button is pressed, the relay is opened, and it is allowed to close only after the fault is solved. |
| Err:LoadBalance | / | / | Flash 9 time (0.5S) | Standby current + charging current < 8A |
9. User Tips
- The Dynamic Load Balancing (DLB) feature and the mobile app are highly praised for their effectiveness and convenience.
- If using the SmartLife app, verify that the current setting is not limited (e.g., to 16A instead of 32A) and ensure proper Wi-Fi connectivity for app control.
- Be aware that the DLB system is not bidirectional, which is important to consider if you have a solar energy system and are concerned about solar injection.
- For installation, consider the cost savings compared to professional services, but ensure proper wiring and grounding.
10. Warranty & Support
Customer Service:
E-mail: tina@feyree.com
Warranty:
Feyree offers a Two-Year Warranty to customers who purchase original Feyree products.
Lifetime Technical Support: In case of any product-related issues, you are encouraged to reach out to Feyree, providing pictures and videos for further assistance.
Exclusions:
The warranty does not cover:
- Any product damage resulting from failure to follow the recommended guidelines.
- Damage caused by unauthorized disassembly of the machine or seeking maintenance from a non-designated service center.
- Purchased non-original Feyree products.
- Any modifications or do-it-yourself alterations carried out without guidance from a licensed electrician.
11. FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and uses can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user's authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antennas.