AISET YLRZ-200 Series

Contents

AISET YLRZ-200 Series Temperature Controller User Manual

Models: YLRZ-200, YLRZ-211, YLGR-200, YLHP-200, RLGR-200, RLHP-200

1. Introduction

This manual provides instructions for the installation, operation, and maintenance of the AISET YLRZ-200 series industrial temperature controllers. These devices are designed for precise temperature regulation in experimental and industrial applications, featuring an LCD display for clear readings and control.

Front view of the AISET YLRZ-200 temperature controller with LCD screen and control buttons.
Figure 1: Front view of the YLRZ-200 Temperature Controller.

2. Specifications

Feature Detail
Model Numbers YLRZ-200, YLRZ-211, RLGR-200, RLHP-200, YLGR-200WG
Power Supply 85-264VAC, 50Hz, 5VA
Sensor Type PT100
Temperature Range 0-400°C (Max Measuring Temperature: 120°C & Above)
Accuracy 0.5 Class
Display Type DIGITAL, LCD (1.9 Inches & Under)
Installation Style Wall Hanging
Use Industrial
Dimensions (L x W x H) 8 cm x 8 cm x 8 cm (approximate package dimensions)
Weight 0.35 kg (approximate package weight)
Origin Mainland China
Back label of the YLRZ-200 temperature controller showing model, temperature range, sensor type, power supply, and serial number.
Figure 2: Product label with key specifications.

3. Setup

3.1. Installation

The temperature controller is designed for wall-hanging installation. Ensure a stable and secure mounting location, away from excessive heat, moisture, or vibrations.

3.2. Wiring

Refer to the internal circuit board diagram for proper wiring connections. Incorrect wiring can damage the device or lead to inaccurate readings.

Internal circuit board of the temperature controller showing terminal blocks for power, sensor input (PT100), and control outputs (OUT, ALM).
Figure 3: Internal wiring diagram. Connect power to L and N terminals. Connect PT100 sensor to the designated PT100 terminals. Control outputs (OUT, ALM) are also visible.
  • Power Connection: Connect the 85-264VAC, 50Hz power supply to the 'L' and 'N' terminals.
  • Sensor Connection: Connect the PT100 temperature sensor to the terminals labeled 'PT100'. Ensure correct polarity if applicable for your specific PT100 sensor type (2-wire, 3-wire, or 4-wire). The diagram shows 3 terminals for PT100, suggesting 3-wire connection.
  • Output Connections: Connect your controlled device (e.g., heater, cooler) to the 'OUT' terminals. Alarm outputs (ALM) are also available for external indicators.
  • Grounding: Ensure proper grounding for safety and stable operation.

Warning: All wiring should be performed by qualified personnel with the power supply disconnected to prevent electric shock.

4. Operating Instructions

4.1. Power On/Off

Once wired correctly, connect the device to the power supply. The LCD screen will illuminate, indicating the device is powered on.

4.2. Basic Operation

The front panel features an LCD display and several control buttons:

  • SET Button: Used to enter parameter setting mode or confirm selections.
  • Arrow Buttons (Up/Down/Left/Right): Used to navigate menus, adjust values, or select options.

The LCD display will typically show the current measured temperature and the setpoint temperature. Consult the full product manual (if available) for detailed programming instructions for specific control modes (e.g., PID, ON/OFF), alarm settings, and calibration.

5. Maintenance

  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning the exterior. Do not use abrasive cleaners or solvents.
  • Inspection: Periodically inspect wiring connections for looseness or damage.
  • Environment: Ensure the operating environment remains within specified temperature and humidity ranges to prolong the device's lifespan.

Caution: Disconnect power before performing any maintenance or cleaning to avoid electric shock.

6. Troubleshooting

  • No Power: Check power supply connections and ensure the voltage is within the 85-264VAC range.
  • Incorrect Temperature Reading: Verify the PT100 sensor is correctly wired and not damaged. Ensure the sensor is properly placed in the measurement area.
  • No Control Output: Check output wiring. Verify setpoint and control parameters are correctly configured.
  • Display Issues: If the LCD is blank or shows erratic characters, power cycle the device. If the problem persists, contact support.

For complex issues, it is recommended to consult a qualified technician or the manufacturer's support.

7. User Tips

No specific user tips are available from provided reviews or Q&A. General tips for temperature controllers include:

  • Always ensure the sensor is correctly calibrated for accurate readings.
  • For critical applications, consider using redundant temperature monitoring.
  • Keep a record of your parameter settings for easy restoration if needed.

8. Warranty and Support

For warranty information, technical support, or service, please refer to the documentation provided with your purchase or contact the seller/manufacturer directly. Keep your purchase receipt as proof of purchase.