1. Introduction
This manual provides detailed instructions for the safe and effective use of the PARMA LS-F series CMOS Laser Distance Sensor. This sensor is designed for precise distance measurement and displacement sensing, offering both switching and analog dual outputs. Please read this manual thoroughly before installation and operation to ensure optimal performance and safety.


2. Safety Precautions
WARNING:
- This product is intended for object inspection (judgment, measurement) and should not be used for safety assurance or to prevent accidents that may affect human life or property.
- This product emits laser radiation. Do not stare directly into the laser beam or observe the optical system through lenses or other optical instruments.
- Ensure the product's light-emitting and light-receiving surfaces are free from water, oil, fingerprints, dust, or debris that could refract or block light. Clean with a soft, dust-free cloth or lens paper if necessary.
- Avoid direct exposure to strong light sources such as fluorescent lamps (quick-start or high-frequency types) or sunlight, as they may interfere with detection.
- The memory write life is approximately 100,000 cycles. If using memory save functions, be mindful of the write life.
3. Product Overview and Components
The LS-F series sensor features a compact design with a digital display and intuitive controls for easy operation and adjustment. It provides high precision measurement with various detection modes.

3.1. Component Identification

The sensor features the following indicators and controls:
- Power Indicator (Red): Indicates power status.
- Laser Emission Indicator (Green): Indicates laser activity.
- SET Indicator (White): Illuminates during SET operations.
- ZERO Indicator (White): Illuminates when zero adjustment is active.
- PRO Indicator (White): Illuminates when in PRO mode.
- Digital Indicator (White): Displays measurement values and settings.
- SET Button: Used for setting parameters and teaching.
- ▲ (Up) / PRO Button: Used for increasing values or entering PRO mode.
- ▼ (Down) Button: Used for decreasing values.
4. Installation
Proper installation is crucial for accurate and reliable operation. Use M3 screws (not included) for mounting and apply a tightening torque of 0.5 N·m.
4.1. Mounting Directions
- Relative to Moving Objects: For materials with varying colors or textures, install the sensor as shown in Figure 5 to minimize measurement errors.
- For Rotating Objects: To mitigate the effects of vertical vibration and positional shifts, install the sensor as shown in Figure 6.
- For Objects with Steps: To suppress the influence of step edges, install the sensor as shown in Figure 7.
- In Narrow Spaces or Holes: Ensure the light path between the emitter and receiver is not obstructed.
- Mounting on Walls: Install the sensor as shown in Figure 8 to prevent multiple reflections from the wall from entering the receiver. If the wall's reflectivity is high, consider painting it matte black for better results.




5. Wiring Diagram
The sensor supports both NPN and PNP output types. Refer to the following diagrams for correct wiring connections.

5.1. Connection Mode (LS-F30/50/100/200/400N)

- Brown: +V (Power Supply)
- Blue: 0V (Ground)
- Black: Control Output
- Pink: External Input (Zero setting/Indoctrination/Stop shining/Trigger)
5.2. Connection Mode (LS-F30/50/100/200/400WN/WP)

- Gray: Analog Output (Voltage: 0~5V / Current: 4~20mA)
- Brown: +V (Power Supply)
- Blue: 0V (Ground)
- Black: Control Output
- Pink: External Input (Zero setting/Indoctrination/Stop shining/Trigger)
6. Operation
6.1. Basic Operation
The sensor's operation panel features a high-definition digital display and thin-film buttons for easy interaction.


The video below demonstrates the sensor's indicator light, laser port, setting key, and analog/numerical display output.
6.2. Teaching (Calibration)
The sensor offers various teaching methods to adapt to different measurement scenarios.
6.2.1. 2-Point Teaching
This is a basic teaching method for stable detection.
- Place a background object and press the SET button.
- Place the detection object and press the SET button again.
6.2.2. Limited Teaching
Useful for detecting small objects against a background.
- Place either a background object or a detection object and press the SET button.
- If the background object is the reference, press the ▲ (Up) key to set the reference value. If the detection object is the reference, press the ▼ (Down) key to set the reference value.
- Teaching is complete.
6.2.3. 1-Point Teaching (Window Comparison Mode)
Used for setting upper and lower limits for detection. This mode must be enabled in PRO mode settings.
- With the detection object in place, press the SET button twice (first for SET mode, second for teaching).
- Teaching is complete.
6.2.4. 2-Point Teaching (Window Comparison Mode)
Used to define a range for detection. This mode must be enabled in PRO mode settings.
- With detection object P-1 in place, press the SET button (first point).
- With detection object P-2 in place, press the SET button (second point).
6.2.5. 3-Point Teaching (Window Comparison Mode)
Used to define a more complex range with two reference values. This mode must be enabled in PRO mode settings.
- With detection object P-1 in place, press the SET button (first point).
- With detection object P-2 in place, press the SET button (second point).
- With detection object P-3 in place, press the SET button (third point).
6.3. Zero Adjustment Function
The zero adjustment function forces the measurement value to "zero". When active, the ZERO indicator (white) illuminates. If peak/valley hold is active, performing zero adjustment will reset the held values.
- To Set Zero: Simultaneously press the ▲ (Up) key and the ▼ (Down) key for 3 seconds. The display will show "ZERO" during this time.
- To Release Zero: Simultaneously press the ▲ (Up) key and the ▼ (Down) key for 6 seconds.
Zero adjustment can also be controlled via external input. Refer to the wiring diagrams for external input connections.
6.4. Peak/Valley Hold Function
This function displays the maximum (peak) or minimum (valley) measured values.
- To Activate: Simultaneously press the SET button and the ▲ (Up) key for 3 seconds to enter the hold setting menu. Use ▲ (Up) or ▼ (Down) to select "Peak Hold" or "Valley Hold", then press SET to confirm.
- To Release: Select "Release Hold Function" in the hold setting menu.
6.5. Reference Value Fine-tuning
The reference value can be fine-tuned directly from the measurement screen, even after teaching.
- In normal detection mode, press the ▲ (Up) or ▼ (Down) key to adjust the reference value. The setting will automatically confirm after approximately 3 seconds of inactivity.
- In window comparison mode, press the SET key for 1 second to switch between adjusting the upper and lower reference values.
6.6. PRO Mode Settings
PRO mode allows advanced configuration of the sensor's behavior. When in PRO mode, the PRO indicator (white) illuminates.
To enter PRO mode, press the ▲ (Up) / PRO button. To exit PRO mode and return to the measurement screen, press the ▲ (Up) / PRO button for 3 seconds.
Key settings in PRO mode include:
- Response Speed: Set reaction time (e.g., 1.5ms, 5ms, 10ms).
- Output Action: Configure output behavior (ON when illuminated, ON when not illuminated).
- Detection Output: Select detection mode (Normal, 1/2/3-point Window Comparison, Rising/Falling Differential).
- Hysteresis: Adjust the hysteresis width.
- External Input: Define the function of the external input (Zero adjustment, Teaching, Stop light emission, Trigger).
- Timer: Set timer actions (No timer, Delay OFF, Delay ON, One-shot timer).
- Display: Switch measurement value display (Normal, Inverted, Offset).
- Hold: Configure control and analog output behavior during measurement errors (Hold OFF, Hold ON).
- Eco Setting: Enable/disable display auto-off for power saving.
- Reset Setting: Restore to factory defaults.
6.7. Key Lock Function
The key lock function prevents accidental changes to settings by disabling button input. When active, pressing any button will display "LOCK" on the digital indicator.
- To Set Key Lock: Simultaneously press the SET button and the ▼ (Down) key for 3 seconds.
- To Release Key Lock: Simultaneously press the SET button and the ▼ (Down) key for 3 seconds.
7. Specifications
The LS-F series offers various models with different detection ranges and output types. Below are general specifications and specific details for some models.



| Item | Specification |
|---|---|
| Light Source | Red semiconductor laser, Class 2 (JIS/IEC/GB) Max Output: 1mW, Wavelength: 655nm |
| Power Supply Voltage | 12V to 24V DC ±10%, Ripple P-P 10% or less |
| Power Consumption | 40mA or less (at 24V DC), 60mA or less (at 12V DC) |
| Control Output | NPN/PNP open-collector transistor (Max 50mA, 30V DC or less) |
| Output Operation | Switchable (Light-ON or Dark-ON) |
| Short-circuit Protection | Incorporated (Auto reset type) |
| Response Time | Switchable between 1.5ms / 5ms / 10ms |
| External Input | NPN non-contact input. Valid: 0 to +1.2V DC, Input impedance: Approx. 10kΩ |
| Protection Degree | IP67 (IEC) |
| Degree of Pollution | 2 |
| Ambient Temperature | Operating: -10 to +40°C (No dew condensation or icing allowed) Storage: -20 to +60°C |
| Ambient Humidity | Operating/Storage: 35% to 85% RH |
| Ambient Illuminance | Incandescent lamp: Acceptance surface illuminance 3,000lx or less |
| Operating Altitude | 2,000m or less |
| Cable | 0.15mm, 5-core composite cable, 2m long |
| Material | Enclosure: Aluminum die-cast, Front cover: Acrylic |
| Weight | Approx. 35g (without cable), Approx. 85g (including cable) |
| Applicable Standard | EMC Directive Compliance |
8. Troubleshooting
If an error occurs, the sensor's digital display will show an error code. Refer to the table below for common error displays and their solutions.
| Error Display | Content | Action |
|---|---|---|
| Measurement value flashes | Insufficient reflected light, or detection object is outside the detection range. | Confirm the detection object is within the measurement range. Adjust the sensor's mounting angle. |
| "E-01" | Flash memory damage or end of service life. | Contact customer support. |
| "E-02" | Excessive current due to short circuit in detection output load. | Turn off power and check the load. |
| "E-03" | Semiconductor laser damage or end of service life. | Contact customer support. |
| "E-04" | Zero adjustment failed (e.g., measurement out of range, offset display active). | Confirm detection distance is within specifications. Set display to something other than offset. |
| "E-05" | Teaching failed (e.g., measurement out of range). | Confirm detection distance is within specifications. |
9. User Tips
- Pink Cable Function: The pink cable serves as an external input for various functions including zero setting, indoctrination (teaching), stopping light emission, or triggering. Its specific function is configured in the PRO mode settings.
- Analog Output: For models with analog output (WN/WP), the gray wire provides either 0-5V voltage or 4-20mA current output, selectable via settings. This allows for continuous measurement data.
- Accuracy: Users have reported excellent accuracy, especially for micrometer measurements. Ensure proper calibration (teaching) for your specific application to achieve the best results.
10. Warranty and Support
For detailed warranty information and technical support, please refer to the official product documentation or contact PARMA Sensor Official Store directly. A comprehensive user manual in PDF format is available for download: User Manual (PDF).