1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of your PowMr Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
The PowMr Hybrid Solar Inverter is a multi-function inverter/charger that combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. Its compact size and comprehensive LCD display offer user-configurable and easy-to-access button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
1.1 Key Features
- Pure Sine Wave Inverter output.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Auto restart while AC is recovering.
- Overload, Over temperature, and Short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Can connect to lithium batteries.
Video: Overview of the PowMr Hybrid Solar Inverter, showcasing its features and components.
1.2 Basic System Architecture
The following diagram illustrates a basic application for this inverter/charger, including connections to a generator or utility, PV modules, and home appliances.

Diagram: Hybrid Power System showing connections between solar panels, generator/utility, inverter, battery, and home appliances.

Diagram: Multiple Charging and Output Modes, including Solar priority, Solar+Utility, Only solar, Utility priority, and SBU mode.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting, please send this inverter/charger back to local dealer or service center for maintenance.
3. Setup (Installation)
3.1 Unpacking and Inspection
Before installation, inspect the unit. Ensure that nothing inside the package is damaged. You should have received the inverter unit and a user manual.
3.2 Preparation
Before connecting all lines, remove the screws under the machine and remove the bottom cover plate.
3.3 Mounting the Unit
Consider the following points when selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Make sure that other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and that there is enough room to remove the wires.
WARNING: Suitable for mounting on concrete or other non-combustible surface only.
Install the unit by screwing two M6 screws.
3.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it is requested to install a separate DC over-current protector or disconnect device between the battery and inverter. It may not be requested to have a disconnect device in some applications, however, it is still requested to have over-current protection installed. Please refer to the typical amperage in the table below for required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It is very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into battery connectors of the inverter and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Make sure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

Diagram: Hybrid Power System for 2KW/3.2KW models, showing connections to solar, generator/utility, battery, and home appliances.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended specification of AC breaker is 32A for 3.6KW/4.2KW and 50A for 6.2KW.
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It is very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW/4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws.
- L → LINE (brown or black)
- N → Neutral (blue)

Diagram: AC Input Wiring connections.
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws.
- L → LINE (brown or black)
- N → Neutral (blue)
- Make sure the wires are securely connected.
CAUTION: Appliances such as air conditioners require at least 2-3 minutes to restart because it is required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check the manufacturer of the air conditioner if it is equipped with a time-delay function before installation. Otherwise, this inverter/charger will trigger an overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.
3.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.
WARNING! It is very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider these parameters:
- Open circuit Voltage (Voc) of PV modules should not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 3.6KW/4.2KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | 500Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | 60Vdc~500Vdc |
3.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
3.8 Communication Connection
Wi-Fi Cloud Communication (Optional)
Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the 'SMARTESS' APP from the App Store or Google Play and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown by the mobile phone APP or computer webpage.

Image: Remote Monitoring and Control via the 'SMARTESS' App, showing the optional WiFi module connection.
GPRS Cloud Communication (Optional)
Use the supplied communication cable to connect to the inverter and GPRS module, and then apply external power to the GPRS module. Download the APP and install it from the App Store, and refer to the “GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown by the mobile phone APP or computer webpage.
Battery Communication
The communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and the lithium battery to exchange information. Baud rate: 9600.
Lithium Battery and Inverter Connection
Use power cables and communication cables for lithium batteries and inverters to connect.
Note: For lithium battery and inverter positive and negative positions, check the correct installation. The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery. Before connecting, make sure that the lithium battery and inverter are turned off. (It is recommended to install a circuit breaker for the power cables of the lithium battery and the inverter battery interface. Otherwise, a spark may occur.)
| CONNECTION METHOD | A-01 | A-02 |
|---|---|---|
| Pin 1 | 1 | 7 |
| Pin 2 | 2 | 8 |
| Pin 8 | 8 | 6 |
| EMPTY PIN IS NOT CONNECTED | ||

Diagram: Lithium Battery Communication Cable Interface, showing RJ45 connections to BMS and RS485 ports.
In "LIB-485" mode, press and hold the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
CAUTION: When the battery type is set to "LIB-485", the setting items 12, 13 and 29 are displayed in percentage. When the battery type is set to "LIB-485", the user cannot modify the maximum charging current. When communication fails, the inverter will cut off the output.
4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The operation and display panel, shown in the diagram below, is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

Image: Front panel of the inverter showing the LCD display and function buttons.
| LED Indicator | Messages |
|---|---|
| INV/AC (Green Solid On) | Output is powered by utility in Line mode. |
| INV/AC (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides various icons to indicate input source, configuration, output, battery, and load information.

Image: LCD Display Icons and their meanings for input, output, battery, and load status.
4.4 LCD Settings
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" buttons to select setting programs, then press "ENTER" to confirm or "ESC" to exit.
Various parameters can be configured, including:
- Output source priority (Program 01): Utility first, Solar first, SBU priority, MKS priority.
- Maximum charging current (Program 02): Configures total charging current for solar and utility chargers.
- AC input voltage range (Program 03): Appliances (default) or UPS.
- Battery type (Program 05): AGM, Flooded, User-Defined, LIB-485.
- Auto restart when overload occurs (Program 06).
- Auto restart when over temperature occurs (Program 07).
- Output frequency (Program 09): 50Hz or 60Hz.
- Output voltage (Program 10): 220V, 230V, 240V.
- Maximum utility charging current (Program 11).
- Setting voltage point back to utility source (Program 12, 13).
- Battery low SOC shutdown point (Program 29).
- Bulk charging voltage (Program 26).
- Floating charging voltage (Program 27).
- Low DC cut-off voltage (Program 29).
- Battery equalization (Program 30).
- Battery equalization voltage (Program 31).
- Battery equalized time (Program 33).
- Battery equalized timeout (Program 34).
- Equalization interval (Program 35).
- Equalization activated immediately (Program 36).
- GRID-tie operation (Program 37): Off-grid or Hybrid.
- GRID-tie current (Program 38).
- Led pattern light (Program 39).
- Dual output (Program 41).
- Enter the dual output functional voltage point (Program 42).
- Lithium battery protocol (Program 43): PYLON or PACE.
- Delayed grid access (Program 44).
- Maximum Second Load (Program 45).
4.5 Operating Mode Description
The inverter supports various operating modes:
- Standby/Power Saving Mode: Inverter is not turned on but can charge the battery. Output is off when connected load is low.
- Line Mode: Unit provides output power from mains and charges the battery.
- Grid-Tie Operation: Inverter operates in grid-tie mode, feeding excess energy to the grid.
- Battery Mode: Unit provides output power from battery and solar.
4.6 Battery Equalization
Battery equalization reverses the buildup of negative chemical effects like stratification and removes sulfate crystals. It is recommended to equalize the battery periodically.
- How to Apply: Enable equalization in LCD setting program 30. Then, set the equalization interval in program 35 or activate immediately in program 36.
- When to Equalize: In float stage, when the setting equalization interval is reached or activated immediately, the controller will enter the Equalize stage.
- Equalize Charging Time and Timeout: The controller charges the battery until it reaches the equalization voltage. If the voltage is still low after the timeout, equalization stops.
4.7 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts to work.
- If the inverter is in lithium battery mode (item 05 is Llb or Llb-485), and the mains is connected but the battery is not, the mains activation function is automatically enabled.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Every inverter is installed with an anti-dust kit from the factory. This kit helps keep dust out of your inverter and increases product reliability in harsh environments. The inverter will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature.
Procedure:
- Loosen the screw in a counterclockwise direction on the top of the inverter.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned every one month.
6. Troubleshooting
Warning: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting, please send this inverter/charger back to local dealer or service center for maintenance.
6.1 Fault Reference Codes
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 01 ERROR |
| 02 | Over temperature | 02 ERROR |
| 03 | Battery voltage is too high | 03 ERROR |
| 04 | Battery voltage is too low | 04 ERROR |
| 05 | Output short circuited or over temperature is detected by internal converter components. | 05 ERROR |
| 06 | Output voltage is too high. | 06 ERROR |
| 07 | Overload time out | 07 ERROR |
| 08 | Bus voltage is too high | 08 ERROR |
| 09 | Bus soft start failed | 09 ERROR |
| 51 | Over current or surge | 51 ERROR |
| 52 | Bus voltage is too low | 52 ERROR |
| 53 | Inverter soft start failed | 53 ERROR |
| 55 | Over DC voltage in AC output | 55 ERROR |
| 57 | Current sensor failed | 57 ERROR |
| 58 | Output voltage is too low | 58 ERROR |
| 59 | PV voltage is over limitation | 59 ERROR |
6.2 Warning Indicators
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
| 6P | Battery is not connected | None | 6P |
6.3 General Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer active for 3 seconds then complete off. | Battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. Battery voltage is far too low (<1.4V/Cell). 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS/Appliance). |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Output short circuited. | Check if wiring is connected well and remove abnormal load. | ||
| Fault code 05 | Temperature of internal converter component is over 120°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | ||
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. | Return to repair center. |
| The battery voltage is too high. | Check if spec and quantity of batteries are meet requirements. | ||
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
7. Specifications
7.1 Line Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Nominal Input Voltage | 230Vac | ||
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | ||
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | ||
| High Loss Voltage | 280Vac±7V | ||
| High Loss Return Voltage | 270Vac±7V | ||
| Max AC Input Voltage | 300Vac | ||
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | ||
| Low Loss Frequency | 40±1Hz | ||
| Low Loss Return Frequency | 42±1Hz | ||
| High Loss Frequency | 65±1Hz | ||
| High Loss Return Frequency | 63±1Hz | ||
| Output Short Circuit Protection | Circuit Breaker | ||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | ||
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | ||
7.2 Inverter Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Rated Output Power | 3.6KW | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | ||
| Output Voltage Regulation | 230Vac±5% | ||
| Output Frequency | 50Hz | ||
| Peak Efficiency | 93% | ||
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | ||
| Surge Capacity | 2* rated power for 5 seconds | ||
| Nominal DC Input Voltage | 24Vdc | 48Vdc | |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc | |
| No Load Power Consumption | 30W | 35W | 50W |
7.3 Two Load Output Power
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Full Load | 3600W | 4200W | 6200W |
| Maximum Main Load | 3600W | 4200W | 6200W |
| Second Load Range | 720W~2520W | 840W~2940W | 1240W~4340W |
| Main Load Cut Off Voltage | 22VDC | 44VDC | |
| Main Load Return Voltage | 26VDC | 52VDC | |
7.4 Charge Mode Specifications
Utility Charging Mode
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Charging Algorithm | 3-Step | ||
| AC Charging Current (Max) | 100Amp (@VI/P=230Vac) | ||
| Bulk Charging Voltage (Flooded Battery) | 29.2 | 58.4 | |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2 | 56.4 | |
| Floating Charging Voltage | 27Vdc | 54Vdc | |
MPPT Solar Charging Mode
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Max. PV Array Power | 6200W | 6200W | 6500W |
| Nominal PV Voltage | 240Vdc | 360Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | ||
| Max. PV Array Open Circuit Voltage | 500Vdc | ||
| Max Charging Current (AC charger plus solar charger) | 120Amp | 120Amp | 120Amp |
7.5 Grid-Tie Operation
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | ||
| Feed-in Grid Voltage Range | 195~253VAC | ||
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | ||
| Nominal Output Current | 15.7A | 18.2A | 26.9A |
| Power Factor Range | >0.99 | ||
| Maximum Conversion Efficiency (DC/AC) | 97% | ||
7.6 General Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Safety Certification | CE | ||
| Operating Temperature Range | -10°C to 50°C | ||
| Storage temperature | -15°C~60°C | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Dimension (D*W*H), mm | 358×442×116 | ||
| Net Weight, kg | 8.0 | 8.0 | 8.9 |
8. User Tips
- Battery-less Operation: Some models of the PowMr Hybrid Solar Inverter can operate without a battery. However, it is crucial to verify this capability for your specific model and ensure proper configuration to avoid damage.
- Battery Compatibility: The inverter is compatible with various battery types, including LiFePO4, AGM, Gel, Flooded, and Sealed Lead Acid batteries. Ensure your battery type is correctly selected in the LCD settings (Program 05) for optimal performance and protection.
- Minimum Starting Voltage: The cold start voltage varies by model: 11.5VDC for 12VDC systems, 23.0VDC for 24VDC systems, and 46.0VDC for 48VDC systems. Ensure your battery voltage meets these requirements for successful startup.
- BMS Communication: While the inverter can operate without Battery Management System (BMS) communication, it is highly recommended for optimal performance and protection, especially with lithium batteries. If BMS communication fails, the inverter may cut off output to prevent damage. Refer to Program 43 for specific battery protocol settings (e.g., PYLON or PACE).
- Fault Code 6P: If you encounter fault code 6P, it indicates that the battery is not connected. Please check all battery connections thoroughly.
9. Warranty & Support
Your PowMr Hybrid Solar Inverter comes with a 12-month warranty.
For technical support, service, or warranty claims, please contact:
- Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
Please have your model number and purchase information ready when contacting support.