Hantek HT360I

Contents

Hantek HT360I Digital Metal Leeb Hardness Tester User Manual

Model: HT360I

Brand: Hantek

1. Introduction

The Hantek HT360I is a portable digital metal Leeb hardness tester designed for accurate and efficient measurement of various metal materials. It operates on the principle of Richter hardness measurement and offers conversion between seven common hardness scales: HL, HB, HRB, HRC, HRA, HV, and HS. This instrument features a streamlined ergonomic design, a 2.8-inch high-definition color display, and large-capacity data storage. It is suitable for testing materials such as steel, cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper-zinc alloy, copper-tin alloy, pure copper, and forged steel. Please read this manual thoroughly before use and keep it for future reference.

Hantek HT360I Digital Metal Leeb Hardness Tester with accessories
Figure 1.1: Hantek HT360I Hardness Tester and included accessories.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and undamaged. The standard package for the HT360I model typically includes:

  • Hantek HT360I Leeb Hardness Tester Unit
  • Standard D-type Impact Device
  • USB Type-C Cable
  • Power Adapter/Charger
  • Cleaning Brush
  • Hardness Test Block (for calibration/verification)
  • Connection Cable for Impact Device
  • Carrying Case
  • Certification Document
  • User Manual (this document)
Layout of Hantek HT360I Hardness Tester and all accessories
Figure 2.1: All components included in the Hantek HT360I package.

Note: The exact accessories may vary slightly depending on the specific model (HT360I, HT360II, HT360C) and region. Refer to the table below for a comparison of accessories across models.

Table 2.1: Model Comparison and Accessories
Model Metal Type Impact Device Format Storage Print Accessories
HT360 I 11 types 5 types 7 types 500 groups Not support 1pcsxbag; 1pcsxcharger; 1pcsximpact device
HT360 II 11 types 5 types 500 groups Not support 1pcsxtoolbox; 1pcsxcharger; 1pcsximpack prohibition; 1pcsxstandard hardness block
HT360C 11 types 5 types 7 types 500 groups Support 1pcsxtoolbox; 1pcsxcharger; 1pcsximpact device; 1pcsxstandard hardness block; 1pcs printer

3. Setup

3.1 Powering On/Off

  • To power on the device, press and hold the Power button (usually marked with a universal power symbol) located on the front panel.
  • The 2.8-inch high-definition display will light up, showing the Hantek logo and then the main measurement interface.
  • To power off, press and hold the Power button again until the device shuts down.

3.2 Connecting the Impact Device

The impact device is crucial for taking measurements. Ensure it is securely connected to the main unit.

  • Locate the "Impact device" port on the top of the main unit.
  • Connect the provided connection cable to the impact device and then to the port on the main unit. Ensure a firm connection.
Top view of Hantek HT360I showing the impact device connection port
Figure 3.1: Impact device connection port on the top of the tester.
Hantek HT360I connected to an impact device
Figure 3.2: Hardness tester with impact device connected.

3.3 Language Settings

The device supports both English and Chinese display. Navigate through the system settings to select your preferred language.

  • From the main interface, press the System button (or corresponding function key, e.g., F1).
  • Use the arrow keys to navigate to the Language option.
  • Select "English" or "Chinese" and confirm your choice.

3.4 PC Connection

The HT360I features a USB Type-C interface for connecting to a computer, allowing for data acquisition, storage, export, and printing via Windows program-controlled software.

  • Connect one end of the provided USB Type-C cable to the tester's USB port.
  • Connect the other end to an available USB port on your computer.
  • Install the Hantek HT360 Series software on your computer (available from the official Hantek website).
  • Follow the software instructions to establish a connection and manage data.
Diagram showing Hantek HT360I connected to a laptop for data acquisition
Figure 3.3: Data acquisition via Windows software and USB Type-C connection.

4. Operating Instructions

4.1 Basic Measurement Procedure

The HT360I uses the Leeb hardness measurement principle. Ensure the impact device is properly loaded and positioned on the test surface.

  • Prepare the Sample: Ensure the surface of the metal sample is clean, smooth, and free from oxidation, oil, or other contaminants. The sample should be stable and thick enough to prevent deformation during impact.
  • Select Material: Press the Material button (or corresponding function key) to select the type of metal material being tested (e.g., Cast Steel, Stainless Steel, etc.).
  • Select Hardness Scale: Press the Scale button to choose the desired hardness scale (HL, HB, HRB, HRC, HRA, HV, HS). The device can convert between these scales automatically.
  • Set Impact Direction: Press the Direction button to set the impact direction based on the orientation of the impact device relative to gravity. The device supports 5 directions: vertical down, oblique down, horizontal, oblique up, and vertical up.
  • Position Impact Device: Place the impact device firmly and perpendicularly on the surface of the test sample.
  • Initiate Impact: Press the release button on the impact device to perform the measurement. The hardness value will be displayed on the screen.
  • Multiple Impact Tests: For improved accuracy, perform multiple impacts (typically 3-5) at different points on the sample surface, ensuring each impact is at least 2mm away from previous impact points and sample edges. The device can calculate the average value.
Hantek HT360I performing a hardness test on a sample block
Figure 4.1: Hardness testing in progress with the impact device on a test block.

4.2 Data Storage and Management

The HT360I has a large internal memory capable of storing up to 500 groups of measurement data. Each data group includes the measurement value, average value, measurement date, impact direction, number of impacts, material type, and hardness system.

  • Saving Data: After a measurement or a series of measurements, press the Save button (or corresponding function key) to store the data.
  • Viewing Stored Data: Press the Times button (or corresponding function key) to browse through the stored measurement records. Use the arrow keys to navigate.
  • Exporting Data: Connect the device to a PC using the USB Type-C cable and the Hantek software to export stored data for further analysis or record-keeping.
  • Printing Data (HT360C only): If you have the HT360C model with an optional Bluetooth printer, you can print measurement results directly from the device. Refer to the printer's manual for pairing and operation instructions.
Hantek HT360I display showing data storage and Bluetooth printing features
Figure 4.2: Display interface showing data storage and optional Bluetooth printing capabilities.

5. Maintenance

5.1 Cleaning

  • Regularly clean the impact device, especially the impact body and guide tube, using the provided cleaning brush to remove any debris or dust.
  • Wipe the main unit's display and casing with a soft, dry cloth. Avoid using abrasive cleaners or solvents.

5.2 Battery Management

The HT360I is powered by a rechargeable lithium battery, offering over 80 hours of continuous operation on a full charge.

  • Charging: Use the provided USB Type-C cable and power adapter to charge the device. The battery indicator on the display will show charging status.
  • Battery Life Optimization:
    • Adjust the backlight time in the system settings to conserve power.
    • Utilize the automatic power-saving and shutdown functions to extend battery life when not in use.
  • Storage: If storing the device for an extended period, ensure the battery is partially charged (around 50%) to prolong its lifespan.

5.3 Storage and Handling

  • Store the device in its carrying case when not in use to protect it from dust, moisture, and physical damage.
  • Avoid exposing the device to extreme temperatures, direct sunlight, or high humidity.
  • Handle the impact device with care; avoid dropping it or subjecting it to strong impacts.

6. Troubleshooting

This section provides solutions to common issues you might encounter. If the problem persists, please contact Hantek support.

Table 6.1: Common Troubleshooting Guide
Problem Possible Cause Solution
Device does not power on. Low battery or battery depleted. Connect the device to the charger and allow it to charge for at least 30 minutes before attempting to power on again.
Inaccurate readings.
  • Impact device not properly cleaned.
  • Incorrect material or hardness scale selected.
  • Impact direction not set correctly.
  • Unstable test sample.
  • Impact device worn out.
  • Clean the impact device thoroughly.
  • Verify the selected material and hardness scale match the sample.
  • Ensure the impact direction is correctly set for the test orientation.
  • Secure the test sample to prevent movement.
  • Consider replacing the impact device if it's old or damaged.
Cannot connect to PC.
  • USB cable faulty or improperly connected.
  • Hantek software not installed or outdated drivers.
  • Device not in PC connection mode (if applicable).
  • Try a different USB port or cable. Ensure the cable is securely connected.
  • Install or update the Hantek HT360 Series software and drivers from the official website.
  • Check the device's system settings for a PC connection mode and enable it if necessary.
Display is blank or frozen. Software glitch or low battery. Perform a hard reset by holding the power button for 10-15 seconds. If the issue persists, ensure the battery is charged.

7. Specifications

Detailed technical specifications for the Hantek HT360I Leeb Hardness Tester.

Table 7.1: Technical Specifications
Parameter Specification
Hardness Scale HL, HB, HRB, HRC, HRA, HV, HS
Measuring Range HLD (170-960), HRC (17.9-69.5), HRB (13.5-101.7), HB (19-683), HV (80-1042), HS (26.4-99.5), HRA (59.1-85.8)
Impact Device Standard D-type, supports DC, DL, D+15, G (optional)
Impact Direction Vertical down, oblique down, horizontal, oblique up, vertical up (5 directions)
Measuring Materials Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper-zinc alloy, copper-tin alloy, pure copper, forged steel
Display 2.8-inch color LCD
Data Storage 500 groups
Interface USB Type-C
Power Supply Rechargeable lithium battery
Continuous Working Time ≥ 80 hours
Operating Temperature 0℃ to +40℃
Storage Temperature -20℃ to +50℃
Humidity ≤ 90% (non-condensing)
Dimensions Approx. 150mm x 76mm x 30mm (L x W x H)
Weight Approx. 200g (main unit)

8. User Tips

  • Surface Preparation is Key: Always ensure the test surface is clean, smooth, and free of any coatings or rust for the most accurate readings.
  • Stable Testing: For best results, place the sample on a stable, heavy surface to prevent movement during impact. Small or light samples should be coupled to a heavier block.
  • Multiple Readings: Take several readings at different points on the sample and use the average value to minimize measurement error.
  • Impact Device Care: The impact device is a precision component. Avoid dropping it and clean it regularly to maintain its performance.

9. Warranty and Support

For detailed warranty information, technical support, and software downloads, please visit the official Hantek website:

When contacting support, please have your product model (HT360I) and any relevant purchase information ready.

10. Product Video Overview

Watch this video for a visual overview of the Hantek HT360I Digital Metal Leeb Hardness Tester and its features.

Video 10.1: Overview of the Hantek HT360I Hardness Tester.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.