Huepar AG2L

Huepar AG2L Digital Angle Gauge and Laser Level

User Instruction Manual

1. Introduction

Thank you for choosing the Huepar AG2L Digital Angle Gauge and Laser Level. This versatile 3-in-1 tool combines a digital angle gauge, a laser level, and an inclinometer, making it ideal for a wide range of applications including woodworking, construction, and various DIY projects. This manual provides detailed instructions for safe operation, setup, and maintenance to ensure optimal performance and longevity of your device.

Huepar AG2L Digital Angle Gauge front view with laser lines
Figure 1: Huepar AG2L Digital Angle Gauge and Laser Level

2. Product Overview

2.1. Package Contents

Ensure all items are present in your package:

  • 1 x Huepar Digital Angle Gauge AG2L
  • 1 x Type-C Charging Cable
  • 1 x Cloth Bag
  • 1 x User Manual
  • 1 x Packing Box
Contents of the Huepar AG2L product package
Figure 2: Package Contents

2.2. Device Components and Display

The Huepar AG2L features a clear VA LCD panel with backlight for easy reading in various lighting conditions. The display value automatically flips when the device is mounted upside down. Key components and display indicators are as follows:

Table 1: Display Components and Functions
No. Component/Indicator Function
1Angle 0-90°/0-180°Indicates the current angle measurement range.
2Data HoldIndicates when the current measurement is held on the display.
3Zero IndicatorIndicates the zero reference point for relative measurements.
4UnitDisplays the selected unit of measurement (°, %, mm/m, IN/FT).
5Measured ValueShows the current angle or inclination reading.
6Low Battery IndicatorAlerts when the battery level is low and requires charging.
7Deviation IndicatorIndicates deviation (while testing in IN/FT unit).
8Angle Position IndicatorShows the orientation of the device relative to horizontal/vertical.
9Audible BuzzerIndicates when the device is near 0° or 90°.
10Laser AperturesEmits the laser lines.
11Power/Date Hold ButtonTurns the device on/off, activates data hold.
12Mode Setting Unit & Audible Buzzer ON/OFF ButtonChanges measurement units and toggles buzzer.
130-90°/0-180° Range Switch & ZERO Function ButtonSwitches angle measurement range and sets zero for relative measurements.
14Laser ON/OFF ButtonActivates or deactivates the laser lines.
15Magnetic V-groove Base & BacksideAllows secure attachment to ferromagnetic and cylindrical surfaces.
Close-up of Huepar AG2L display and buttons
Figure 3: Front View of Device with Display

3. Specifications

Table 2: Technical Specifications
Feature Specification
ModelAG2L
Laser ClassClass 2 (IEC/EN60825-1/2014), <1mW power output
Measuring Range (Single axis)4*0° ~ 90° and 2*0° ~ 180°
Resolution0.05° (1-99.9°) / 0.1° (100°-180°)
Angle Accuracy±0.1° at 0°/90°/180°; ±0.2° at other angles
Laser Accuracy± 1mm/m (1/25.4 inch at 3.3ft)
Power Source650 mAh lithium battery
Working TimeUp to 14 hours (4 hours with 2 laser lines + angle measurement)
Charging PortType-C
Working Temperature0℃ ~ 40℃
Storage Temperature-10℃ ~ 50℃
Weight150g
DurabilityIP54 Waterproof and Dustproof

4. Setup

4.1. Charging the Device

The Huepar AG2L is equipped with a 650mAh lithium battery. Before first use, or when the low battery indicator appears, charge the device using the provided Type-C charging cable.

  1. Connect the Type-C charging cable to the charging port on the side of the device.
  2. Connect the other end of the cable to a suitable USB power adapter (not included).
  3. The device will indicate charging status on its display. A full charge can provide up to 14 hours of use (4 hours with both laser lines and angle measurement active).
Huepar AG2L showing Type-C charging port and cable connected
Figure 4: Type-C Charging

4.2. Initial Placement

The device features strong magnets on its bottom and back sides, along with a V-groove design on the bottom. This allows for secure attachment to ferromagnetic surfaces and cylindrical objects like pipes.

Huepar AG2L showing built-in magnet and V-groove design
Figure 5: Built-in Magnet and V-Groove

5. Operating Instructions

5.1. Power On/Off

  • To turn ON the device, short press the Power/Date Hold button (11).
  • To turn OFF the device, long press the Power/Date Hold button (11).

5.2. Measurement Modes (Absolute and Relative)

The AG2L offers two measurement modes:

  • Absolute Measurement (ABS): Measures the true angle relative to the horizontal plane.
  • Relative Measurement (REF): Measures the angle relative to a user-defined zero point.

To switch between modes or set a relative zero:

  1. Turn on the device.
  2. Place the device on the surface you wish to set as the relative zero.
  3. Short press the 0-90°/0-180° Range Switch & ZERO Function button (13) to set the current position as 0.00° for relative measurement. The 'Zero Indicator' (3) will appear.
  4. Press the button again to return to absolute measurement.
Huepar AG2L showing Absolute and Relative Angle Measurement modes
Figure 6: Absolute vs. Relative Measurement

5.3. Laser Line Modes

The device features three laser line modes:

  • Horizontal Line: Projects a horizontal laser line.
  • Vertical Line: Projects a vertical laser line.
  • Cross Line: Projects both horizontal and vertical laser lines simultaneously.

To activate or change laser modes:

  • Short press the Laser ON/OFF button (14) to cycle through the laser modes (Horizontal, Vertical, Cross-Line, Off).
User demonstrating Horizontal, Vertical, and Cross-Line laser modes
Figure 7: 3 Laser Line Modes

5.4. Unit Conversion

The AG2L supports four units of measurement:

  • Degrees (°)
  • Percentage (%)
  • mm/m
  • IN/FT (Fraction)

To change the unit of measurement, short press the Mode Setting Unit & Audible Buzzer ON/OFF button (12) to cycle through the available units.

Huepar AG2L displaying measurements in Degree, Percentage, mm/m, and in/ft
Figure 8: 4 Units of Measurement

5.5. Buzzer Function

The audible buzzer (9) will alert you when the device is within ±1° of the horizontal (0°) or vertical (90°) position. To toggle the buzzer ON/OFF, long press the Mode Setting Unit & Audible Buzzer ON/OFF button (12).

Huepar AG2L showing buzzer prompt icon
Figure 9: Buzzer Prompt

5.6. Data Hold

To hold the current measurement on the display, short press the Power/Date Hold button (11) during measurement. The 'Data Hold' indicator (2) will appear. Press the button again to release the hold and resume live measurement.

5.7. User Calibration

It is crucial to perform calibration on a flat and smooth surface. If the surface exceeds 5° of deviation, the display will show "Err", indicating that calibration cannot proceed. During calibration, the device must not be beveled or moved. After successful calibration, the device's original factory data will be replaced with your calibrated data, so use this function carefully.

  1. With the AG2L turned OFF, press and hold both the Power/Date Hold button (11) and the Laser ON/OFF button (14) simultaneously to enter calibration mode. The display will show "CAL 1".
  2. Short press the Laser ON/OFF button (14). "CAL 1" will blink.
  3. The display will then change to "CAL 2".
  4. Carefully flip the level over so that the bottom surface is now facing upwards, resting on the same flat surface.
  5. Short press the Laser ON/OFF button (14) again. "CAL 2" will blink, then change to the active angle display.
  6. The zero reference for the display has now been recalibrated to the level surface.
Video 1: User Calibration Guide for Huepar AG2L

6. Maintenance

  • Keep the device clean and dry. Use a soft, damp cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
  • Store the device in its cloth bag when not in use to protect it from dust and scratches.
  • The device is IP54 waterproof and dustproof, but avoid submerging it in water.
  • Regularly check the battery level and recharge as needed to maintain battery health.
Huepar AG2L demonstrating IP54 waterproof and dustproof features
Figure 10: Durable IP54 Design

7. Troubleshooting

Table 3: Common Issues and Solutions
Problem Possible Cause Solution
Display shows "Err" during calibrationCalibration surface is not flat or exceeds 5° deviation.Ensure the device is placed on a perfectly flat and smooth surface for calibration.
Inaccurate angle readingsDevice needs calibration; magnetic interference.Perform user calibration as described in Section 5.7. Ensure no strong magnetic fields are nearby during measurement.
Laser lines are dim or not visibleLow battery; bright ambient light.Recharge the device. Use the device in lower light conditions or closer to the target surface.
Device does not turn onBattery is depleted.Charge the device fully using the Type-C cable.
Buzzer not workingBuzzer function is turned off.Long press the Unit button to toggle the buzzer ON.

8. User Tips

  • For critical measurements, always perform a quick calibration check to ensure accuracy.
  • Utilize the magnetic base and V-groove for hands-free operation on metal surfaces and pipes, enhancing stability and precision.
  • The compact size makes it easy to carry and use in tight spaces. Always keep the cloth bag handy for transport.
  • When using laser lines, ensure the surface is clear of obstructions for a clear projection.
  • Remember that the display automatically flips, so you can read measurements comfortably even when the device is upside down.
Huepar AG2L in various application scenarios like woodworking and construction
Figure 11: Versatile Application Scenarios

9. Warranty and Support

Huepar provides a standard warranty for this product against defects in materials and workmanship under normal use. For detailed warranty terms, technical support, or service inquiries, please refer to the official Huepar website or contact your local distributor. Keep your purchase receipt as proof of purchase for warranty claims.


Huepar AG2L Digital Angle Gauge with Laser: Precision Level and Angle Finder

Huepar AG2L Digital Angle Gauge with Laser: Precision Level and Angle Finder

0:34 • 1280×720 • feature_demo

Related Documents - AG2L

Preview Huepar Digital Angle Gauge AG03 User Manual
User manual for the Huepar Digital Angle Gauge AG03, detailing product overview, operation, specifications, and warranty information. Includes instructions on battery replacement, power on/off, buzzer prompt, reference measurement, holding measurement values, level measurement modes, menu operations, and calibration.
Preview Huepar 5011G Self-leveling Cross Line Laser Level User Manual
User manual for the Huepar 5011G self-leveling cross line laser level. Provides instructions on product overview, safety, operation, charging, and warranty.
Preview Huepar Laser Level W04CG Function Introduction and Usage Guide
This document provides a detailed introduction to the functions and operation of the Huepar Laser Level W04CG, including status indicators, connection features, laser line control, battery status, and important safety notes.
Preview Huepar LM50A/LM100A/LM120A Laser Distance Measure User Manual
Comprehensive user manual for the Huepar LM50A, LM100A, and LM120A Laser Distance Measure. Learn about product features, safety instructions, operation, and maintenance.
Preview Huepar 9011G/9011R, 9211G/9211R Cross Line/Plumb Spot Combo Laser Level User Manual
User manual for the Huepar 9011G/9011R and 9211G/9211R Cross Line/Plumb Spot Combo Laser Level, covering safety instructions, product overview, operation modes, specifications, and warranty.
Preview Huepar 7211CG/7211CR Laser Level User Manual
Comprehensive user manual for the Huepar 7211CG/7211CR Cross Line/Plumb Spot Combo Laser Level, covering product overview, safety instructions, operation modes, specifications, and warranty.