1. Introduction
The LDIR05 microwave induction radar is a 24GHz (ISM standard frequency band) motion detector designed for detecting targets with motion speeds ranging from 1 km/h to 250 km/h. It outputs signals or commands for approach, distance, or presence, with an adjustable detection range. This module offers strong anti-interference capabilities and is not affected by environmental factors such as temperature, humidity, or dust.


2. Key Features
- 24GHz ISM standard frequency band motion detector.
- Maximum detection distance up to 200 meters for vehicles.
- Detection distance configurable via sensitivity settings.
- Serial TTL communication interface.
- High anti-interference capability, unaffected by temperature, humidity, or dust.
3. Specifications
| Parameter | Value |
|---|---|
| Operating Frequency | 24-24.250GHz |
| Working Voltage | DC12V |
| Maximum Operating Current | 34mA (at VCC=12V) |
| Typical Working Current | 34mA (at VCC=12V) |
| Detection Range (Horizontal) | 46° (3dB) |
| Detection Range (Vertical) | 24° (3dB) |
| Detection Distance (Human Movement) | ≥ 50 meters |
| Detection Distance (Vehicle Movement) | ≥ 200 meters |
| Working Temperature | -40°C to +80°C |
| Working Humidity | <93% RH |
| Dimensions | 78.75 mm × 30 mm |



4. Setup and Installation
The LDIR05 module is designed for integration into various systems. Proper setup involves power connection and establishing serial communication.
4.1 Power Connection
Connect the module to a DC12V power supply. Ensure correct polarity to avoid damage. The module typically consumes 34mA at 12V.
4.2 Communication Interface
The module uses Serial TTL communication. Connect the appropriate TX/RX pins to your control system (e.g., microcontroller, computer with a TTL-to-USB converter). Refer to the specific pinout on the module for correct connections.
4.3 Mounting
The module dimensions are 78.75 mm × 30 mm. It features mounting holes (BH1, BH3) for secure installation. Ensure the module is mounted in a position that provides an unobstructed view of the detection area, considering its horizontal (46°) and vertical (24°) detection ranges.
5. Operating Instructions
Once powered and connected via Serial TTL, the LDIR05 module will begin detecting motion. The detection range can be adjusted through sensitivity settings via the serial interface. The module outputs signals or commands related to target approach, distance, or presence.
5.1 Sensitivity Adjustment
The detection distance can be configured by adjusting the sensitivity. This is typically done by sending commands via the Serial TTL interface. Consult the module's communication protocol documentation (not provided here) for specific commands and parameters.
5.2 Data Output
The module provides data via Serial TTL. This data will indicate the presence, distance, and approach/recede of detected targets. For example, for human movement, it can detect up to 50 meters, and for vehicle movement, up to 200 meters.
6. Maintenance
The LDIR05 radar module is designed for robust operation with minimal maintenance. However, adhering to the following guidelines can ensure optimal performance and longevity:
- Cleaning: Keep the module's antenna surface clean and free from dust, dirt, or obstructions. Use a soft, dry cloth for cleaning. Avoid abrasive materials or harsh chemicals.
- Environmental Conditions: While the module has strong anti-interference capabilities and operates within a wide temperature range (-40°C to +80°C) and humidity (<93% RH), prolonged exposure to extreme conditions outside these specifications should be avoided.
- Firmware Updates: Check with the manufacturer for any available firmware updates that might improve performance or add new features.
7. Troubleshooting
If you encounter issues with your LDIR05 radar module, consider the following troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| No detection or inconsistent detection |
|
|
| No data output via Serial TTL |
|
|
| False detections |
|
|
8. User Tips
- For optimal vehicle detection, ensure the module has a clear, unobstructed view of the road or area where vehicles are expected.
- When integrating with microcontrollers, start with basic serial communication examples to confirm data reception before implementing complex logic.
- Consider the module's beam patterns (46° horizontal, 24° vertical) when planning its placement to maximize coverage and minimize unwanted detections.
9. Warranty and Support
9.1 Warranty Information
All products come with a 1-year warranty from the date of receipt. During this period, full refunds or replacements are provided for defective merchandise.
9.2 Technical Support
For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding communication protocols and advanced configurations, please contact the manufacturer or your sales representative. They provide excellent after-sales service and support.