iSolution LDIR05

Rate this product
Contents

LDIR05 24G Human Presence Induction Radar Module User Manual

Model: LDIR05

Brand: iSolution

1. Introduction

The LDIR05 microwave induction radar is a 24GHz (ISM standard frequency band) motion detector designed for detecting targets with motion speeds ranging from 1 km/h to 250 km/h. It outputs signals or commands for approach, distance, or presence, with an adjustable detection range. This module offers strong anti-interference capabilities and is not affected by environmental factors such as temperature, humidity, or dust.

Top view of the LDIR05 radar module showing electronic components and connectors.
Figure 1: LDIR05 Radar Module (Top View)
Bottom view of the LDIR05 radar module showing antenna array.
Figure 2: LDIR05 Radar Module (Bottom View with Antenna Array)

2. Key Features

  • 24GHz ISM standard frequency band motion detector.
  • Maximum detection distance up to 200 meters for vehicles.
  • Detection distance configurable via sensitivity settings.
  • Serial TTL communication interface.
  • High anti-interference capability, unaffected by temperature, humidity, or dust.

3. Specifications

ParameterValue
Operating Frequency24-24.250GHz
Working VoltageDC12V
Maximum Operating Current34mA (at VCC=12V)
Typical Working Current34mA (at VCC=12V)
Detection Range (Horizontal)46° (3dB)
Detection Range (Vertical)24° (3dB)
Detection Distance (Human Movement)≥ 50 meters
Detection Distance (Vehicle Movement)≥ 200 meters
Working Temperature-40°C to +80°C
Working Humidity<93% RH
Dimensions78.75 mm × 30 mm
LDIR05 radar module with attached wires for connection.
Figure 3: LDIR05 Radar Module with Wiring
LDIR05 radar module showing a side perspective with components.
Figure 4: LDIR05 Radar Module (Side View)
Dimensional drawing of the LDIR05 radar module, showing length 78.75mm and width 30.00mm.
Figure 5: LDIR05 Radar Module Dimensions (78.75mm x 30.00mm)

4. Setup and Installation

The LDIR05 module is designed for integration into various systems. Proper setup involves power connection and establishing serial communication.

4.1 Power Connection

Connect the module to a DC12V power supply. Ensure correct polarity to avoid damage. The module typically consumes 34mA at 12V.

4.2 Communication Interface

The module uses Serial TTL communication. Connect the appropriate TX/RX pins to your control system (e.g., microcontroller, computer with a TTL-to-USB converter). Refer to the specific pinout on the module for correct connections.

4.3 Mounting

The module dimensions are 78.75 mm × 30 mm. It features mounting holes (BH1, BH3) for secure installation. Ensure the module is mounted in a position that provides an unobstructed view of the detection area, considering its horizontal (46°) and vertical (24°) detection ranges.

5. Operating Instructions

Once powered and connected via Serial TTL, the LDIR05 module will begin detecting motion. The detection range can be adjusted through sensitivity settings via the serial interface. The module outputs signals or commands related to target approach, distance, or presence.

5.1 Sensitivity Adjustment

The detection distance can be configured by adjusting the sensitivity. This is typically done by sending commands via the Serial TTL interface. Consult the module's communication protocol documentation (not provided here) for specific commands and parameters.

5.2 Data Output

The module provides data via Serial TTL. This data will indicate the presence, distance, and approach/recede of detected targets. For example, for human movement, it can detect up to 50 meters, and for vehicle movement, up to 200 meters.

6. Maintenance

The LDIR05 radar module is designed for robust operation with minimal maintenance. However, adhering to the following guidelines can ensure optimal performance and longevity:

  • Cleaning: Keep the module's antenna surface clean and free from dust, dirt, or obstructions. Use a soft, dry cloth for cleaning. Avoid abrasive materials or harsh chemicals.
  • Environmental Conditions: While the module has strong anti-interference capabilities and operates within a wide temperature range (-40°C to +80°C) and humidity (<93% RH), prolonged exposure to extreme conditions outside these specifications should be avoided.
  • Firmware Updates: Check with the manufacturer for any available firmware updates that might improve performance or add new features.

7. Troubleshooting

If you encounter issues with your LDIR05 radar module, consider the following troubleshooting steps:

ProblemPossible CauseSolution
No detection or inconsistent detection
  • Incorrect power supply (voltage or current).
  • Obstruction in the detection path.
  • Incorrect sensitivity setting.
  • Module not properly aimed.
  • Verify power supply is DC12V and provides sufficient current.
  • Ensure clear line of sight for the radar.
  • Adjust sensitivity via Serial TTL commands.
  • Re-position the module to cover the desired area.
No data output via Serial TTL
  • Incorrect wiring for Serial TTL.
  • Incorrect baud rate or communication settings.
  • Module not powered on.
  • Check TX/RX connections and ensure they are not swapped.
  • Verify baud rate and other serial communication parameters match the module's default or configured settings.
  • Confirm the module is receiving power.
False detections
  • High sensitivity setting.
  • Environmental interference (e.g., strong electromagnetic fields, vibrations).
  • Reduce sensitivity via Serial TTL commands.
  • Relocate the module away from potential sources of interference.

8. User Tips

  • For optimal vehicle detection, ensure the module has a clear, unobstructed view of the road or area where vehicles are expected.
  • When integrating with microcontrollers, start with basic serial communication examples to confirm data reception before implementing complex logic.
  • Consider the module's beam patterns (46° horizontal, 24° vertical) when planning its placement to maximize coverage and minimize unwanted detections.

9. Warranty and Support

9.1 Warranty Information

All products come with a 1-year warranty from the date of receipt. During this period, full refunds or replacements are provided for defective merchandise.

9.2 Technical Support

For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding communication protocols and advanced configurations, please contact the manufacturer or your sales representative. They provide excellent after-sales service and support.

© 2024 iSolution. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?