BSIDE U0 U1

Contents

BSIDE U0 U1 Digital Clamp Meter User Manual

Model: U0 U1 | Brand: BSIDE

Introduction

The BSIDE U0 U1 Digital Clamp Meter is a new generation smart True RMS DC/AC 100A Fork Open-Jaw digital clamp meter designed for professional electricians, engineers, electronic enthusiasts, and home use. Its OpenJaw design facilitates convenient current testing and maintenance. This device offers intelligent and professional measurement functions, including temperature testing, with a full-function analog bar multiple display.

BSIDE U0 U1 Digital Clamp Meter with test leads and charging cable

Figure 1: BSIDE U0 U1 Digital Clamp Meter and accessories.

Safety Information

Please read and understand all safety information before operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always ensure the device is in good working condition before use.
  • Do not attempt to measure voltages or currents exceeding the specified maximum ratings.
  • Use appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses when working with electricity.
  • Avoid using the meter in wet environments or when your hands are wet.
  • Before measuring capacitance, ensure the capacitor is fully discharged to prevent damage to the meter or injury.
  • The device is rated CAT III 600V. Adhere to safety standards for the environment you are working in.

Package Contents

Verify that all items listed below are included in your package:

  • 1 x BSIDE U1 Electronic Tester Clamp Meter
  • 1 x Upgrade Test Leads
  • 1 x Built-in Rechargeable Battery (pre-installed)
  • 1 x USB Charging Cable (Type-C)
  • 1 x Carrying Case
  • 1 x User Manual
  • 1 x Color Box
  • 1 x T1101 Test Leads (Tool Kits - if applicable)
  • 1 x T9004 Test Leads (Tool Kits - if applicable)
Package contents for BSIDE U1 Digital Clamp Smart Multimeter, including test leads, charging cable, carrying case, and manuals.

Figure 2: Typical package contents for the BSIDE U1 model.

Product Overview

The BSIDE U0 U1 features an intuitive design with an EBTN Color HD LCD display and an OpenJaw for non-contact current measurements. It integrates multiple functions into a compact form factor.

Key Features:

  • OpenJaw Design: For convenient AC/DC current measurement without breaking the circuit.
  • EBTN Color HD LCD Display: Provides clear readings with an analog bar multiple display.
  • True RMS: Accurate measurements for non-sinusoidal waveforms.
  • Smart Mode: Automatic recognition of measurement type for ease of use.
  • Built-in Rechargeable Lithium Battery: USB Type-C charging for convenience.
  • V-Alert (NCV) Function: Non-contact voltage detection for safety.
  • Flashlight: For illumination in dimly lit work areas.
  • Automatic Shutdown: Conserves battery life.
  • Low Battery Indication: Alerts when charging is needed.
Full function multimeter with lithium battery power supply, intelligent recognition, and burn protection.

Figure 3: Overview of the multimeter's intelligent features.

Icons representing various functions: Temperature, Auto, Live, Lithium direct charge, AC/DC Current, Flashlight, NCV, Frequency, AC/DC Voltage, Zero, Resistance, Capacitance, Diode, On/Off, Automatic shutdown, Duty.

Figure 4: Visual representation of available functions.

Setup

1. Initial Charging

The device comes with a built-in rechargeable lithium battery. Before first use, it is recommended to fully charge the meter.

  1. Locate the Type-C charging port on the back of the meter.
  2. Connect the provided USB Type-C charging cable to the meter and a suitable USB power adapter (not included).
  3. The charging indicator on the display will show the charging status. Charge until the battery icon indicates full charge.
Lithium direct charge Type-C interface for the clamp meter, showing how to connect the charging cable and the 90-degree swivel for battery access.

Figure 5: Charging the device via Type-C USB. The back cover can be unscrewed 90 degrees counter-clockwise to access the battery.

2. Connecting Test Leads

For voltage, resistance, capacitance, diode, and continuity measurements, connect the test leads:

  1. Insert the black test lead into the "COM" (common) input jack.
  2. Insert the red test lead into the "INPUT" jack.
  3. Ensure the test leads are securely connected before taking any measurements.

Operating Instructions

Power On/Off

  • Press the red power button (U) to turn the meter ON.
  • The meter will automatically enter "AUTO" mode upon startup, intelligently recognizing the measurement type.
  • To turn OFF, press and hold the red power button (U) until the display turns off. The meter also features automatic shutdown after 15 minutes of inactivity.

Measurement Functions

1. AC/DC Current Measurement (OpenJaw)

The OpenJaw design allows for non-contact current measurement. The meter automatically recognizes AC or DC current.

  1. Turn on the meter. It will default to AUTO mode.
  2. Press the "A~" button to select AC or DC current measurement if not automatically detected.
  3. Place the OpenJaw around a single conductor (not a bundle of wires) through which the current is flowing.
  4. Read the current value on the display.
Demonstration of AC current measurement using the clamp meter, showing the OpenJaw around a single wire.

Figure 6: AC Current Measurement.

Demonstration of DC current measurement using the clamp meter, showing the OpenJaw around a single wire.

Figure 7: DC Current Measurement.

Actual measurement demonstration showing AC current, DC current, AC voltage, DC voltage, continuity, and resistance measurements.

Figure 8: Various measurement demonstrations.

2. AC/DC Voltage Measurement

The meter automatically recognizes AC or DC voltage in AUTO mode.

  1. Connect the test leads as described in the Setup section.
  2. Turn on the meter. It will default to AUTO mode.
  3. Touch the red test lead to the positive terminal and the black test lead to the negative terminal or ground of the circuit/component.
  4. Read the voltage value on the display.

3. Resistance Measurement

The meter automatically recognizes resistance in AUTO mode.

  1. Connect the test leads.
  2. Ensure the circuit or component is de-energized before measuring resistance.
  3. Touch the test leads across the component to be measured.
  4. Read the resistance value on the display.

4. Capacitance Measurement

Important: Before measuring capacitance, always discharge the capacitor first to prevent damage to the meter or injury.

  1. Connect the test leads.
  2. Ensure the capacitor is fully discharged.
  3. Touch the test leads across the capacitor terminals.
  4. Read the capacitance value on the display.
Capacitance test demonstration, showing discharge of capacitor before measurement.

Figure 9: Capacitance Measurement.

5. Diode and Continuity Test

The meter automatically recognizes diode and continuity in AUTO mode.

  1. Connect the test leads.
  2. For diode test, touch the test leads across the diode. The display will show the forward voltage drop.
  3. For continuity test, touch the test leads across the circuit path. A buzzer will sound and the backlight will turn red if resistance is less than 50Ω.

6. Frequency Measurement

To measure frequency:

  1. Connect the test leads.
  2. Apply the test leads to the circuit where frequency needs to be measured.
  3. Read the frequency value on the display.

7. Temperature Measurement

The meter supports temperature measurement using a K-type thermocouple (not explicitly listed in package, but mentioned in features image).

  1. Connect the K-type thermocouple to the meter's input jacks (ensure correct polarity).
  2. Place the thermocouple probe at the point where temperature needs to be measured.
  3. Read the temperature value on the display.

8. V-Alert (Non-Contact Voltage Detection)

This feature allows for safe detection of AC voltage without direct contact.

  1. Bring the top of the instrument (NCV sensor) closer to the AC power supply or live wire.
  2. The meter will sound an alarm and the display will indicate the presence of AC voltage.
Non-contact voltage detection (NCV) demonstration near an electrical outlet, showing the meter detecting AC voltage.

Figure 10: Non-Contact Voltage Detection.

9. Live Wire Check

This function helps identify live wires.

  1. Insert a single probe into the socket or touch a single wire.
  2. The meter will indicate if it's a live wire.

10. Zero/Reset Function

Press the "ZERO" button to reset the current reading or clear previous measurements, especially useful for DC current measurements to eliminate residual magnetism.

Maintenance

Charging the Battery

The meter is powered by a built-in rechargeable lithium battery. When the low battery indicator appears on the display, connect the USB Type-C cable to charge the device. A full charge typically allows for 5 hours of continuous operation.

Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning.

Storage

When not in use for extended periods, store the meter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. It is advisable to charge the battery periodically to maintain its health.

Troubleshooting

  • Meter does not power on: Ensure the battery is charged. Connect the USB-C cable and try again.
  • Inaccurate readings:
    • Check if test leads are properly connected.
    • Ensure the correct measurement mode is selected (if not using AUTO mode).
    • For current measurements, ensure the OpenJaw is around a single conductor.
    • For resistance/capacitance, ensure the circuit is de-energized and components are isolated.
    • Perform a "ZERO" reset for DC current if needed.
  • No continuity beep: Check if the circuit is complete and resistance is below 50Ω.
  • NCV/Live wire detection not working: Ensure the sensor is close enough to the AC source. Check for any obstructions.

Specifications

Detailed specifications for the BSIDE U0 U1 Digital Clamp Meter:

Boundary dimension and specifications table for the BSIDE U0 U1 Digital Clamp Meter, detailing ranges, resolutions, and accuracies for various functions.

Figure 11: Dimensions and detailed specifications table.

General Specifications
AttributeValue
Brand NameBSIDE
Model NumberBSIDE U0 U1 Fork DC AC 100A Digital Clamp Meter
BSIDE ModelU1
DIY SuppliesElectrical
Display TypeAnalog and Digital
Max Display6000 counts
True RMSYes
Battery IncludedYes
PowerBuilt-in rechargeable lithium battery
Operating Temperature0-40°C
Dimensions18.1*3*2.9CM
Weight0.3kg
CertificationCE, FCC, RoHS

Measurement Ranges
FunctionRangeResolutionAccuracy
DC Voltage0~610V0.001V± (0.8%+3)
AC Voltage0~610V0.001V± (1.0%+3)
DC Current1~100A0.1A± (2.5%+5)
AC Current1~100A0.1A± (2.5%+5)
Resistance0.1Ω~60MΩ0.1Ω± (1.2%+3)
Capacitance0.01μF~60mF0.1μF± (2.0%+10)
Frequency1Hz~9.999MHz0.001Hz± (2.0%+10)
Duty Cycle10.0~95.0%0.1%± 3.0%
Temperature-50~1000°C1°C± 2.0%
ContinuityIf the resistance <50Ω, the buzzer sounds and red backlight on
DiodeMeasure diodes within 3V
V-AlertYes
Auto power off15 minutes
FlashlightYes

User Tips

  • For precise current measurements, ensure the OpenJaw completely encloses only one conductor. Measuring multiple conductors simultaneously will result in an inaccurate reading (e.g., measuring both live and neutral wires will show zero current).
  • The auto-ranging feature is very convenient for general use, but for specific applications, you can manually select the range if available for more controlled measurements.
  • Always keep the meter and test leads clean to ensure good contact and accurate readings.
  • Utilize the built-in flashlight when working in dark areas to improve visibility and safety.

Warranty and Support

BSIDE products are designed for reliability and performance. This product typically comes with a 12-month warranty from the date of purchase, covering manufacturing defects. For technical support, warranty claims, or service inquiries, please contact BSIDE Official Store customer service through your purchase platform or refer to the contact information provided in your warranty card.

Video 1: Unboxing and demonstration of the BSIDE U0 U1 Digital Clamp Meter's features and usage.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.