1. Introduction and Features
Thank you for choosing the PowMr MPPT Solar Charger Controller. This series utilizes advanced Maximum Power Point Tracking (MPPT) control algorithms to efficiently track the maximum power point of your PV array in any environment, significantly improving energy utilization in your solar system. The controller features a dual display function (LCD and optional Remote header) and a standard communication interface for extended application and comprehensive monitoring.
This controller series includes 20A, 30A, and 40A models, all offering high MPPT charging efficiency of 97% and a maximum charging current of 40A. It incorporates a three-stage charging algorithm to optimize battery performance and extend battery life. With a maximum PV input voltage of 100V, it is suitable for various 12V or 24V lithium-ion and lead-acid battery systems. The built-in DC output port delivers 30A of direct current, making it suitable for powering DC loads.
Key Features:
- Advanced MPPT maximum power point tracking technology with tracking efficiency no less than 99.5%.
- High conversion efficiency, reaching up to 97%.
- Super-fast maximum power tracking speed.
- Accurate identification and tracking of multi-wave peak maximum power points.
- Reliable maximum input power for PV array to ensure equipment safety.
- Wide PV array maximum power point operating voltage range.
- 12V/24V automatic voltage identification.
- LCD for dynamic display of operation data and working status.
- Various load control modes: general mode, light control mode, dual time mode, pure charger mode, and timing mode.
- Supports Seal, GEL, Flooded, LiFePO4, and Li(NiCoMn)O2 battery charging processes.
- Battery temperature compensation function.
- Power statistics recording function.
- External display unit and other peripherals for real-time data view and parameter setting.
Kind Tip: The controller will initiate the PWM function at the High Voltage Disconnection (HVD) voltage point. This limits voltage rising to protect the battery.
Video: Overview of PowMr MPPT Solar Charger Controller features and models.
2. Product Appearance and Components

Figure 1: Front view of the PowMr MPPT Solar Charger Controller with labeled components.
| No. | Component | Description |
|---|---|---|
| ① | LCD | Liquid Crystal Display for operational data. |
| ② | Temperature sensor interface (Selection) | Port for connecting an external temperature sensor. |
| ③ | Photovoltaic array terminals | Terminals for connecting solar panels (PV array). |
| ④ | Battery terminal | Terminals for connecting the battery. |
| ⑤ | Load terminal | Terminals for connecting DC loads. |
| ⑥ | Menu Button | Used to navigate through display parameters. |
| ⑦ | Set Button | Used to change and confirm parameter settings. |
| ⑧ | USB output | Dual USB ports for charging external devices. |
NOTICE: If a remote temperature sensor is not connected, the controller will compensate charging parameters by 25°C for the battery temperature.
3. Setup and Installation
3.1 Safety Precautions
- Ensure all connections are secure and correct before powering on.
- Always connect the battery first, then the solar panel. Disconnect in reverse order.
- Install the controller in a well-ventilated area, away from direct sunlight and heat sources.
- Avoid installing in areas with flammable or explosive gases.
- Use appropriate wire gauges for all connections to prevent overheating.
3.2 Wiring Instructions
Follow these steps for proper wiring:
- Open the Cover: First, open the cover of the controller to access the screw terminals. You may need to rotate a screw to release the cover.
- Wire the Battery: Connect the battery cables to the battery terminals (④) on the controller. Ensure correct polarity (+ to + and - to -).
- Wire the PV Array: Connect the solar panel (PV array) cables to the photovoltaic array terminals (③). Ensure correct polarity.
- Wire the Load (Optional): Connect your DC loads to the load terminals (⑤). Ensure correct polarity.

Figure 2: Step-by-step visual guide for wiring the controller.

Figure 3: Example wiring diagram for a complete solar power system.
4. Operating Instructions
4.1 LCD Display and Navigation
The LCD provides real-time information about your solar system. Use the Menu Button (⑥) to cycle through different display screens and the Set Button (⑦) to change parameters.

Figure 4: At-a-glance display interface showing various operational screens.
Common display screens include:
- Main Interface: Displays battery voltage (BAT), system voltage (e.g., 12V), and temperature.
- System Voltage Select: Allows selection of system voltage (e.g., Ut:00).
- Total Charge Power: Shows accumulated PV charge (PV, 0AH).
- Load Mode: Displays current load control mode (e.g., 24H, OFF).
- Total Load Power: Shows accumulated load consumption (LOAD, 0AH).
- Load Disconnect Voltage: Configurable voltage at which load is disconnected (e.g., 11.0V OFF).
- Float Voltage: Displays the float charge voltage (e.g., 13.8V OFF).
- Load Reconnect Voltage: Configurable voltage at which load is reconnected (e.g., 12.6V ON).
4.2 Battery Type Selection
The controller supports various battery types. You can select the appropriate charging process for:
- User default
- Sealed Lead-Acid
- Flooded Lead-Acid
- GEL Lead-Acid
- LiFePO4 (Lithium Iron Phosphate)
- Li(NiCoMn)O2 (Lithium Nickel Manganese Cobalt Oxide)

Figure 5: MPPT+PWM Charging and supported battery modes.
4.3 Load Control Modes
The controller offers four load output modes to configure load output conditions and durations:
- Manual Mode (24H): Load is continuously on.
- Solar Light Control Mode: Load turns on at sunset and turns off at sunrise.
- Solar Light + Time Control: Load turns on at sunset and stays on for a set duration, then turns off.
- Pure Charger Mode: The controller acts solely as a charger, with no load output.
- Timing Mode: Load operates based on a user-defined schedule.

Figure 6: Visual representation of the various load working modes.
5. Maintenance
- Regularly check all wiring connections for tightness and corrosion.
- Keep the controller clean and free from dust and debris.
- Ensure adequate ventilation around the controller to prevent overheating.
- Periodically inspect the battery terminals for corrosion and clean if necessary.
- Monitor the LCD display for any error codes or unusual readings.
- If an external temperature sensor is used, ensure it is securely connected and positioned correctly for accurate readings.
6. Troubleshooting
This section provides guidance for common issues. For more complex problems, please contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Controller not powering on | Battery not connected or low voltage; incorrect wiring. | Check battery connections and voltage. Ensure battery is connected first. |
| No charging from PV | PV array not connected; insufficient sunlight; PV voltage too low/high. | Check PV connections and polarity. Ensure adequate sunlight. Verify PV open circuit voltage is within controller limits. |
| Load not working | Load disconnected; low battery voltage; incorrect load mode setting. | Check load connections and polarity. Ensure battery voltage is above LVD. Verify load control mode settings. |
| Inaccurate temperature reading | External temperature sensor not connected or faulty. | Ensure external temperature sensor is properly connected. If not, the controller uses a default compensation. |
7. Specifications
| Parameter | POW-Keeper1220 (20A) | POW-Keeper1230 (30A) | POW-Keeper1240 (40A) |
|---|---|---|---|
| Rated charge current | 20A | 30A | 40A |
| System rated voltage | 12V/24V Auto work | ||
| Voltage range of battery | 8-32V | ||
| Max open voltage of PV module | 55V | 75V | 100V |
| Battery type | User default, Sealed, Flooded, GEL, LiFePO4 | ||
| Equalized charging voltage | Maintenance-free lead acid battery: 14.6V; GEL: No; Lead acid flooded battery: 14.8V | ||
| Absorption charging voltage | Maintenance-free lead acid battery: 14.4V; GEL: 14.2V; Lead acid flooded battery: 14.6V | ||
| Floating charging voltage | Maintenance-free lead acid battery, GEL, Lead acid flooded battery: 13.8V | ||
| Low voltage re-connection (LVR) | Maintenance-free lead acid battery, GEL, Lead acid flooded battery: 12.6V | ||
| Low voltage disconnection (LVD) | Maintenance-free lead acid battery, GEL, Lead acid flooded battery: 10.8V | ||
| Static loss | <9.2mA (12V); <11.7mA (24V) | ||
| High voltage disconnection (HVD) | 16V (24V x 2) | ||
| Duration of absorption charging | 2 Hours | ||
| Light control voltage | 5V | ||
| Charge loop voltage drop | <0.29V | ||
| LCD Temperature | -20°C~+70°C | ||
| Operating Temperature | -20°C-+55°C (To run at full rated current continuously) | ||
| Working humidity | <95% No condensation | ||
| Protection class | IP30 | ||
| Dimension (LxWxH) mm | 123x178x48 | 135x202x55 | 150x220x67 |
8. User Tips
- For optimal performance, ensure your solar panel array voltage is well within the controller's maximum open voltage limits for your specific model (55V, 75V, or 100V).
- Always double-check the polarity of all connections (PV, battery, load) before powering on to prevent damage to the controller and connected devices.
- When setting up, configure the battery type first to ensure correct charging parameters are applied.
- Utilize the various load control modes to optimize power usage for your specific application, such as automatic lighting control for street lamps.
- If you experience any issues, refer to the troubleshooting section before contacting support. Many common problems can be resolved with simple checks.
9. Warranty and Support
For warranty information and technical support, please refer to the documentation included with your product or contact PowMr Official Store customer service. Keep your purchase receipt as proof of purchase for any warranty claims.