1. Product Overview

The Daxtromn AGH Series is a multi-function hybrid solar inverter/charger designed to provide uninterruptible power support. It integrates the functions of an inverter, solar charger, and battery charger into a portable unit. The comprehensive LCD display allows for user-configurable settings and easy operation, including battery charging current, AC/solar charger priority, and acceptable input voltage for various applications.

This inverter is capable of powering a wide range of home and office appliances, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

Key Features:

  • Pure Sine Wave Output
  • Max 120A/140A MPPT Solar Charger (model dependent)
  • Max 500VDC PV Input
  • Dual Load Output (2 AC outputs)
  • Supports Battery Management System (BMS) communication
  • High PV input voltage range (90~450VDC)
  • Output power factor 1.0
  • Real Hybrid Solar inverter for 24V/48V systems
  • Optional WiFi Module for remote monitoring and control
  • Efficient operation with or without battery
  • Bundled monitoring & setting software
  • Supports 50Hz or 60Hz (program adjustable)
  • Able to use AC grid or generator power
  • Built-in anti-dusk kit for harsh environments
  • Optional DC output for DC fans, LED bulbs, routers, etc.

Product Video Overview:

Play video
Watch video online

Video: A brief overview of the AGH Series inverter, showcasing its physical features, ports, and LCD display.

Daxtromn AGH Series Hybrid Solar Inverter front view
Figure 1: Front view of the Daxtromn AGH Series Hybrid Solar Inverter.

2. Product Specifications

The following tables detail the technical specifications for the AGH-4.2KW PRO and AGH-6.2KW PRO models.

Detailed specifications table for AGH-4.2KW PRO and AGH-6.2KW PRO
Figure 2: Detailed specifications for AGH-4.2KW PRO and AGH-6.2KW PRO.

General Specifications:

  • Brand Name: pyrosolar
  • Model Number: AGH-4.2KW AGH-6.2KW BMS
  • Output Type: DUAL
  • Is Smart Device: Yes
  • Origin: Mainland China
  • Certification: CE
  • Operating Temperature: -10 ~ 50℃
  • Number of Load output: 2
  • With BMS: Yes (for BMS models)
  • Work without battery: Yes

Dimensions and Weight:

Product dimensions and net weight
Figure 3: Product dimensions and net weight.
  • Size: 42.4*33.5*11cm (approx. 423 x 334 x 110 mm / 16.7 x 13.2 x 4.3 in)
  • Weight: 4.2KW 9.5kg, 6.2KW 10kg

3. Product Components and Display

Familiarize yourself with the various components and the LCD display of your inverter.

Product overview diagram with numbered parts and descriptions
Figure 4: Product overview with labeled components.

Component Identification:

No.Component
1LCD display
2Status indicator
3Charging indicator
4Fault indicator
5Function buttons
6Power on/off switch
7AC input
8Main output
9Second output
10Battery input
11PV input
12RS-232 communication port/WiFi-port
13Circuit breaker
14BMS/RS485

4. Installation and Wiring

Safety Warnings:

WARNING: Shock Hazard! Installation must be performed by a qualified personnel.

WARNING: It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable size as below.

CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules. Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

CAUTION: Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 32A for 3.6KW and 50A for 6.2KW/7.2KW.

CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.

DO NOT CONNECT THE SECOND OUTPUT TO THE GRID, IT WILL DAMAGE YOUR INVERTER.

Mounting:

Install the unit by screwing two screws. It's recommended to use M6 screws. The inverter is suitable for mounting on concrete or other non-combustible surfaces only.

Connection Diagram:

General connection diagram for solar inverter system
Figure 5: General connection diagram showing solar panels, battery, utility, generator, and home appliances.

PV Connection:

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
PV connection diagram and recommended wire size table
Figure 6: PV connection diagram and recommended wire sizes.
ModelWire SizeCable (mm²)Torque Value (Max)
3.6KW / 6.2KW / 7.2KW1 x 12 AWG41.2 Nm

Battery Connection:

Please follow below steps to implement battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
Diagram showing battery wire preparation with ferrules
Figure 7: Battery wire preparation.
  1. Connect all battery packs as below chart.
Battery connection diagram for 3.6KW and 6.2KW/7.2KW inverters
Figure 8: Battery connection diagram.

Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

Diagram showing how to insert and tighten battery wires
Figure 9: Battery wire insertion and tightening.
ModelWire SizeCable (mm²)Torque value (max)
3.6KW/6.2KW/7.2KW1 x 2AWG252 Nm

AC Input/Output Connection:

AC input/output connection diagram
Figure 10: AC Input/Output Connection Diagram.

Suggested Cable Requirement for AC Wires:

ModelGaugeCable (mm²)Torque Value
3.6KW12 AWG41.2 Nm
6.2KW/7.2KW10 AWG61.2 Nm

5. Operating Instructions

Charging Modes:

Diagram showing four charging modes and three discharge modes
Figure 11: Four charging modes and three discharge modes.

The inverter supports four charging modes:

  • CSO Solar First: Solar energy is prioritized for charging.
  • Utility First: Utility power is prioritized for charging.
  • SNU Solar and Utility (default): Solar and utility power are used for charging.
  • OSO Only Solar: Only solar energy is used for charging.

Discharge Modes:

The inverter supports three discharge modes:

  • SUB Solar First (Default): Solar energy is prioritized for discharge.
  • USB Utility First: Utility power is prioritized for discharge.
  • SBU Priority: A combination of solar, battery, and utility power is used based on priority settings.

Off-Grid or Hybrid Mode Setup:

Table showing settings for Off Grid and Hybrid operation modes
Figure 12: Grid-tie operation settings.
Setting No.OperationModeDescription
37GRID-tie operationOFF (Default)Inverter operates only in off-grid mode. Solar energy provides power to the loads as first priority and charging second.
HYBInverter operates hybrid mode. Solar energy provides power to the loads as first priority and charging second. Excess energy feed to grid.

NOTE: The default mode is OFF GRID mode (Will not send energy to network).

Dual AC Output Function:

The inverter features dual AC outputs (Main Out and Second Out). Under normal conditions, both outputs are active. However, if there is no PV or mains power input and the battery voltage drops below a set threshold, the Main AC Out will automatically cut off. Only the Second AC Out will continue to receive power from the battery or PV, ensuring that critical equipment remains operational.

6. Monitoring and Control

The AGH Series inverter can be monitored and controlled via the SmartESS App, which requires an optional WiFi module.

SmartESS App interface for monitoring and control
Figure 13: Monitor and control via SmartESS App.

The WiFi module and GPRS data need to be purchased separately. The app is available on Google Play and the App Store.

7. Safety and Protection

The inverter is equipped with comprehensive 360° protection features to ensure safe and reliable operation.

Diagram illustrating various protection features of the inverter
Figure 14: Comprehensive 360° protection features.

Protection Features:

  • Over Charge Protection
  • Backfill Protection
  • Over-Load Protection
  • Under Voltage Protection
  • Over Current Protection
  • Over Voltage Protection
  • Short Circuit Protection
  • Over-Temperature Protection

8. Troubleshooting

Common Issues and Solutions:

  • Inverter not working normally without external battery: If the solar inverter is used without an external battery, the voltage connected to the solar panel must be above 150V for the inverter to operate normally. If an external battery is present, 120V is sufficient.
  • Inductive Loads: When connecting inductive loads (e.g., motors, pumps, refrigerators, air conditioners), consider that their starting current can be significantly higher than their rated power. For example, a 1000W water pump may require an inverter with a specification above 3KW due to the large instantaneous current during startup and operation. Similarly, electromagnetic heating equipment with large induced electromotive force and current requires careful consideration of inverter capacity. It is recommended to multiply the inductive load's power by more than 3 times when sizing the inverter.
  • BMS Communication: For proper communication and automatic parameter adjustment (charging voltage, cut-off voltage) between the inverter and battery, both the inverter and the battery must have BMS functions.

9. Maintenance

To ensure optimal performance and longevity of your Daxtromn AGH Series Hybrid Solar Inverter, follow these maintenance guidelines:

  • Regular Cleaning: Keep the inverter's exterior clean and free from dust and debris. Ensure ventilation openings are not blocked to prevent overheating.
  • Connection Checks: Periodically inspect all wiring connections (PV, battery, AC input/output) to ensure they are secure and free from corrosion. Loose connections can lead to poor performance or safety hazards.
  • Environmental Conditions: Ensure the inverter is operating within its specified temperature range (-10°C to 50°C) and in a dry, well-ventilated area.
  • Firmware Updates: If using the optional WiFi module, check for available firmware updates through the SmartESS App to ensure your inverter has the latest features and bug fixes.

10. User Tips

  • Verify Inverter Parameters: Before full deployment, perform preliminary checks to confirm the inverter's parameters match specifications.
  • Fan Operation: The inverter's fans are designed to work quietly under normal operation. If you notice unusual fan noise, ensure proper ventilation and check for obstructions.
  • BMS Integration: If your battery has a BMS, ensure it is properly connected and communicating with the inverter for optimized battery life and safety.

11. Warranty and Support

Warranty:

This product comes with a 1 Year Warranty from the date of purchase.

Customer Support:

For any technical assistance, troubleshooting, or warranty claims, please contact your authorized Daxtromn dealer or the point of purchase. Ensure you have your product model number and purchase details ready when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.