Ourtrop ATMS100133

Ourtrop 3 Phase WiFi Smart Energy Meter Instruction Manual

Model: ATMS100133

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Ourtrop ATMS100133 3 Phase WiFi Smart Energy Meter. This device is designed for accurate measurement and monitoring of electrical energy in three-phase systems, offering smart control and data access via a mobile application.

Ourtrop 3 Phase WiFi Smart Energy Meter with three current transformer clamps
Figure 1: Ourtrop 3 Phase WiFi Smart Energy Meter with Current Transformers.

2. Safety Information

Please read all safety warnings and instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Installation should only be performed by a qualified electrician.
  • Ensure power is disconnected before performing any wiring or maintenance.
  • Do not operate the device in wet or damp conditions.
  • Verify all connections are secure to prevent loose wiring and potential hazards.

3. Product Specifications

The Ourtrop ATMS100133 Smart Energy Meter provides precise measurements and smart connectivity for your electrical system.

AttributeValue
Model NumberATMS100133
WiFi TypeATMS100133
Zigbee TypeATMS100133Z
Nominal Voltage (UN)100-240V AC (50/60Hz)
Operating Range(0.8...1.1)UN
Rated Power2.2VA/0.7W
Current Range0.02A ~ 100A
WiFi Frequency2.4GHz
Ambient Temperature Range-20℃ ~ +60℃
MountingDIN Rail 35 mm (EN 60715)
Dimensions10*8.5*8.5 cm (approx. 90mm x 65.5mm x 18mm)
Accuracy Class0.5
Measuring Energy Range0-99999
PhaseThree Phase
Max Operating Current80A - 99A
Rated Voltage240V
Power SupplyAC
Display TypeAPP
DIY SuppliesElectrical
CertificationCE
Product parameters table for Ourtrop Smart Energy Meter
Figure 2: Detailed Product Parameters.
Dimensions of the Ourtrop 3 Phase WiFi Smart Energy Meter
Figure 3: Device Dimensions (approx. 90mm x 65.5mm x 18mm).

4. Installation and Setup

4.1. Physical Installation

The Ourtrop Smart Energy Meter is designed for DIN Rail mounting (35 mm, EN 60715). Ensure sufficient space for wiring and ventilation.

4.2. Wiring Diagram

Follow the wiring diagram carefully. Incorrect wiring can damage the device or lead to inaccurate readings. This meter is designed for three-phase systems.

Detailed wiring diagram for the 3 Phase WiFi Smart Energy Meter with MCCB and CT clamps
Figure 4: Detailed Wiring Diagram for 3-Phase System.
Connection diagrams and current transformer clamp direction
Figure 5: Connection Diagrams and CT Clamp Direction.

Wiring Precautions:

  1. Current Transformer (CT) Installation:
    • Ensure the direction of the internal P1 to P2 is carefully checked.
    • Current direction P1 to P2: Measure the positive active power.
    • The black wire of the transformer must be connected to the B1 terminal.
    • The red wire of the transformer must be connected to the B2 terminal.
    • The black wire of the transformer must be connected to the B3 terminal.
    • The red wire must be connected to the B2 terminal.

    Note: The above terminals cannot be connected incorrectly.

  2. Voltage Wiring:
    • L1 wire: The black wire of transformer 1 must be connected to the B1 terminal.
    • L2 wire: The black wire of transformer 2 must be connected to the B2 terminal.
    • L3 wire: The black wire of transformer 3 must be connected to the B3 terminal.
    • N wire: Connect to the N terminal.

4.3. App Pairing

The meter supports connection via WiFi (2.4GHz) and Bluetooth. It is compatible with the Tuya Smart / Smart Life app.

  1. Download and install the "Tuya Smart" or "Smart Life" app from your mobile app store.
  2. Register or log in to your account.
  3. Ensure your device is powered on and the indicator light is blinking (pairing mode). If not, reset the device by pressing the reset button for 5 seconds.
  4. In the app, tap "Add Device" or the "+" icon.
  5. Select the appropriate device type (e.g., "Gateway" or "Zigbee 3 Phase Meter" if available, or search for "Power Strip (Wi-Fi)" or similar if not directly listed).
  6. Follow the on-screen prompts to connect to your 2.4GHz WiFi network and enter the password.
  7. Confirm the indicator is blinking in the app.
  8. The app will discover and add the device. Once successfully added, you can rename it and start monitoring.
Video 1: App Pairing and Data Display Demonstration.

5. Operation

Once connected to the mobile app, you can monitor various electrical parameters and manage your energy usage.

5.1. App Functions and Monitoring

The mobile application provides real-time data and historical records for comprehensive energy management:

  • Total Active Energy (kWh): Overall energy consumption.
  • Positive Active Energy (kWh): Energy consumed from the grid.
  • Reverse Active Energy (kWh): Energy fed back to the grid (e.g., from solar panels).
  • Total Active Power (kW): Instantaneous total power consumption.
  • Total Reactive Power (kVar): Instantaneous reactive power.
  • Total Power Factor: Indication of electrical efficiency.
  • Each Phase: Current (A), Voltage (V), Power (W): Detailed measurements for each of the three phases.
  • Bidirectional Metering: Capable of measuring energy flow in both directions.
Screenshot showing app functions for energy meter, including various energy and power readings
Figure 6: Mobile App Interface displaying monitoring functions.

5.2. Device Sharing

The energy meter's data can be shared with up to 20 users via the mobile application, allowing multiple household members or authorized personnel to monitor energy usage.

6. Maintenance

The Ourtrop Smart Energy Meter is designed for low maintenance. Regular checks can help ensure optimal performance:

  • Periodically check all wiring connections for tightness and signs of wear or damage.
  • Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning.
  • Ensure the operating environment stays within the specified temperature range (-20℃ to +60℃).
  • Regularly update the mobile application to the latest version for new features and bug fixes.

7. Troubleshooting

If you encounter issues with your energy meter, refer to the following common problems and solutions:

  • Device not connecting to Wi-Fi:
    • Ensure your Wi-Fi network is 2.4GHz. The device does not support 5GHz networks.
    • Check if the device is in pairing mode (blinking indicator light). If not, reset it.
    • Verify your Wi-Fi password is correct.
    • Ensure the device is within range of your Wi-Fi router.
  • Inaccurate readings:
    • Double-check all wiring connections, especially the Current Transformer (CT) clamp directions (P1 to P2).
    • Ensure the CT clamps are securely closed around the correct phase wires.
  • App not displaying data:
    • Confirm the device is successfully connected to the app and online.
    • Check your internet connection on your mobile device.
    • Restart the app or the energy meter.

8. User Tips

  • App Compatibility: This device is compatible with the Tuya Smart and Smart Life applications, allowing for integration into existing smart home ecosystems.
  • Electric Vehicle Charging: While designed for 3-phase systems, this meter can potentially monitor 2-phase 220VAC loads (like some EV chargers) if wired correctly, by utilizing two of the three available phases. Consult a qualified electrician for specific wiring configurations for non-standard setups.
  • Cable Length: The current transformer cables are typically designed for standard installation distances. If longer cables are required, ensure they are of appropriate gauge and quality to maintain accuracy and safety.

9. Warranty and Support

For warranty information, technical support, or further assistance, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

© 2023 Ourtop. All rights reserved.


Related Documents - ATMS10013300:00

Preview Airzone AZX8AC Series WIFI Energy Meter Technical Specifications and Installation Guide
Detailed technical specifications, installation instructions, and operational information for the Airzone AZX8AC Series WIFI Electricity and Energy Meter, supporting single-phase and three-phase applications.
Preview IGEN DTSD422-D3-WiFi Three-Phase Smart Meter User Manual and Specifications
Comprehensive user manual and technical specifications for the IGEN DTSD422-D3-WiFi three-phase smart meter, detailing its features, parameters, wiring, LED indicators, and Solarman app integration.
Preview KOWSI KWS-306 Series: 3-Phase 4-Wire Multi-function Energy Meter | Technical Specifications & Features
Detailed overview of the KOWSI KWS-306 series multi-function energy meters, including KWS-306, KWS-306WF (WiFi), and KWS-306L (RS485). Features include high-definition display, rail mounting, comprehensive protection functions, and mobile app control. Ideal for residential, commercial, and industrial electrical monitoring.
Preview Shelly 3EM Triple Phase WiFi Energy Meter User Guide
User guide for the Shelly 3EM, a triple-phase WiFi energy meter by Allterco Robotics. Learn about its specifications, installation, features like energy theft detection, and control via the Shelly Cloud app or web interface.
Preview Dreamburgh Three Phase Tuya WiFi Smart Bi-Directional Energy Meter Specifications
Technical specifications and features for the Dreamburgh Three Phase Tuya WiFi Smart Bi-Directional Energy Meter, including voltage, current, and installation details.
Preview Airzone Wi-Fi Electricity Consumption Meter Quick Guide
Quick guide for the Airzone single-phase/three-phase Wi-Fi electricity consumption meter (AZX8ACxMTW) and clamp (AZX8ACCMTWC). Covers installation, connection, configuration, and monitoring of electricity usage via the Airzone Cloud app.

Ask a question about this manual