1. Introduction

This manual provides detailed instructions for the installation, configuration, and operation of your NicetyMeter FT016TH and FT007TH wireless thermo-hygrometer add-on sensors. These sensors are designed to wirelessly transmit temperature and humidity data to a compatible NicetyMeter weather station (e.g., FT-0320 series), allowing for remote monitoring of various environments.

Please read this manual thoroughly before using the sensors to ensure proper functionality and to maximize their lifespan.

2. Package Contents

Verify that you have received the following items:

  • NicetyMeter FT016TH or FT007TH Wireless Thermo-Hygrometer Sensor
  • User Manual (this document)

Note: 2x AAA 1.5V batteries are required per sensor and are not included.

3. Sensor Overview

Familiarize yourself with the main components and display elements of your sensor.

Diagram of FT016TH sensor display with labels for Temperature, Relative Humidity, Temperature Units, and Channel Number.
Figure 3.1: FT016TH Sensor Display Overview
  • Temperature Display: Shows the current temperature.
  • Relative Humidity Display: Shows the current relative humidity percentage.
  • Temperature Units: Indicates whether the temperature is displayed in °C (Celsius) or °F (Fahrenheit).
  • Channel Number: Displays the assigned channel (CH1-CH8).
Back view of FT007TH sensor showing battery compartment and DIP switches for channel and unit selection.
Figure 3.2: FT007TH Sensor Rear View (Battery Compartment and DIP Switches)
Back view of FT016TH sensor showing battery compartment, DIP switches for channel selection, and Celsius/Fahrenheit switch.
Figure 3.3: FT016TH Sensor Rear View (Battery Compartment and DIP Switches)

4. Setup

4.1 Battery Installation

Each sensor requires two (2) AAA 1.5V batteries (not included). Follow these steps to install them:

  1. Open the battery compartment cover on the back of the sensor.
  2. Insert 2x AAA 1.5V batteries, ensuring correct polarity (+ and -).
  3. Close the battery compartment cover securely.
Close-up of FT016TH battery compartment with batteries inserted and DIP switches visible.
Figure 4.1: Battery Installation (FT016TH shown)

For a visual guide on battery installation and DIP switch settings, please refer to the product video below:

Video 4.1: Sensor Battery Installation and DIP Switch Configuration

4.2 Channel and Unit Selection (DIP Switches)

Before closing the battery compartment, configure the DIP switches located inside. These switches allow you to set the sensor's transmission channel and temperature unit (°C/°F).

Combined image showing FT016TH display details and battery/DIP switch setup.
Figure 4.2: FT016TH DIP Switch Configuration

Channel Selection (CH1-CH8):

  • Each sensor must be assigned a unique channel (1-8) if you are using multiple sensors with your weather station.
  • Refer to the diagram on the sensor's back cover or inside the battery compartment for the correct DIP switch combination for each channel.
  • Ensure the selected channel on the sensor matches the desired channel on your main weather station console for proper data reception.

Temperature Unit Selection (°C/°F):

  • Locate the dedicated DIP switch for temperature units.
  • Set it to the desired unit: 'UP' for Fahrenheit (°F) or 'DOWN' for Celsius (°C).

Note: After changing DIP switch settings, you may need to remove and reinsert batteries to apply the changes.

4.3 Sensor Placement

Choose an appropriate location for your sensor. The sensors are designed for both indoor and outdoor use, but consider the following:

  • Outdoor Placement: Place the sensor in a shaded area, protected from direct sunlight and rain, to ensure accurate temperature and humidity readings. Avoid placing it near heat sources (e.g., vents, appliances) or reflective surfaces.
  • Indoor Placement: Place the sensor in the area you wish to monitor, away from direct drafts or heat sources.
  • Mounting: The sensors can be placed on a flat surface or mounted on a wall using the integrated hanging hole or screw slots.
Image showing two placement methods for the sensor: hanging on a hook and wall-mounted.
Figure 4.3: Sensor Placement Methods

The maximum transmission range is 30 meters (free field). Obstacles like walls and electronic interference can reduce this range. Ensure the sensor is within range of your main weather station console.

Diagram illustrating that up to 8 temperature and humidity sensors can be placed and connected to a weather station console.
Figure 4.4: Multiple Sensor Connectivity

5. Operating Instructions

Once batteries are installed and channels are set, the sensor will automatically begin transmitting data. Your main weather station console should detect the sensor and display its readings.

5.1 Reading the Sensor Display

The sensor's built-in LCD display shows the current temperature, relative humidity, and its assigned channel number. This allows for local verification of readings.

Close-up of FT016TH sensor display showing temperature 22.9°C, humidity 51%RH, and channel CH1.
Figure 5.1: FT016TH Sensor Live Display

5.2 Pairing with Weather Station

Refer to your main NicetyMeter weather station's manual for specific instructions on how to pair new wireless sensors or select different channels. Generally, the weather station will have a "SCAN" or "CHANNEL" button to search for and display data from connected sensors.

Diagram showing a weather station console connected to an outdoor sensor and a 2.4G router for data upload to online weather services.
Figure 5.2: Weather Station System Overview (including sensor communication)

6. Maintenance

6.1 Battery Replacement

When the sensor's display becomes dim or the weather station console indicates a low battery for a specific channel, it's time to replace the batteries. Follow the battery installation steps (Section 4.1) to replace the 2x AAA 1.5V batteries.

6.2 Cleaning

Wipe the sensor's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these may damage the casing or electronic components. Ensure the sensor is dry before re-exposing it to the environment.

7. Troubleshooting

  • No Reading on Weather Station:
    • Ensure batteries are correctly installed and not depleted.
    • Verify the sensor's channel DIP switches match the channel selected on the weather station.
    • Check if the sensor is within the 30-meter transmission range and there are no major obstructions.
    • Try resetting both the sensor (by removing and reinserting batteries) and the weather station (refer to its manual).
  • Inaccurate Readings:
    • Relocate the sensor away from direct sunlight, heat sources, or areas with high humidity (e.g., near a humidifier).
    • Allow the sensor to stabilize in its new location for at least 30 minutes.
    • Ensure the sensor's vents are not blocked.
  • Intermittent Signal:
    • Reduce the distance between the sensor and the weather station.
    • Minimize electronic interference from other devices (e.g., Wi-Fi routers, cordless phones).
    • Replace batteries if they are low.

8. Specifications

FeatureSpecification
Temperature Range-20°C to 60°C (-4°F to 140°F)
Temperature Accuracy±1°C (±2°F)
Temperature Steps0.1°C/°F
Humidity Range20% to 95% RH
Humidity Accuracy±5% (guaranteed between 20% to 90%)
Humidity Steps1%
Transmission Frequency433.92 MHz
Max Transmission Power< 10mW
Transmission Range30 meters (free field)
Power Supply2x AAA 1.5V batteries (not included)
Dimensions (FT016TH)75 x 53 x 22 mm
Dimensions (FT007TH)110 x 45 x 20 mm
CertificationCE

9. User Tips

  • Optimal Battery Life: Use high-quality alkaline batteries for best performance and longer battery life. Avoid mixing old and new batteries.
  • Signal Strength: For optimal signal strength, try to place the sensor and the main weather station console on the same floor and avoid placing them near large metal objects or thick concrete walls.
  • Calibration: While these sensors are factory calibrated, if you suspect a significant discrepancy, compare readings with another known accurate thermometer/hygrometer in the same location.
  • Multiple Sensors: When using multiple sensors, ensure each is set to a unique channel using the DIP switches to prevent interference and ensure correct data display on your weather station.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.